Carrollton, Carroll County

Holiday Inn Express

1545 HWY 27 S CARROLLTON, GA 30117

Pool
Latest score
100
May 12, 2026
City
Carrollton
County
Carroll
Inspections
8

Score history

Inspection scores over time for this facility.

Inspection history

Georgia inspection history is score-based, with violations grouped under each recorded inspection.

May 12, 2026

Permit/Opening

Score: 1000 violations
No violations recorded for this inspection.

Jul 16, 2025

Routine

Score: 1000 violations
No violations recorded for this inspection.

Jun 5, 2025

Permit/Opening

Score: 961 violation

26 - gauge(s) in proper location; sight glass installed

Regulation: 511-3-5-.09(9)(b) - (b) the pressure gauge shall be installed downstream from the pump, on the face piping ahead of the filter or on top of the filter in the area of greatest filter pressure.

4 ptsCorrected: NoRepeat: No

Replace pressure gauge

May 27, 2025

Complaint

Score: 852 violations

6 - proper disinfectant level

Regulation: .17((1)(c) - proper disinfectant level

15 ptsCorrected: NoRepeat: No

Free chlorine reading at 0 ppm. Pool will remain closed until chlorine levels are in compliance.

7 - ph between 7.2 and 7.8

Regulation: 511-3-5-.17(2) - (2) chemical values: ph

15 ptsCorrected: NoRepeat: No

Observed high pH greater than 8.0

Aug 20, 2024

Routine

Score: 951 violation

36 - daily recordkeeping: water testing and self inspection performed

Regulation: 511-3-5-.22(9) - (9) water testing frequency. the trained operator or responsible person shall collect water samples from the water in the pool for monitoring. an in-line sampling port may be used for water held in reservoirs. the water quality testing frequency shal

5 ptsCorrected: NoRepeat: No

Keep daily records up to date. Make sure CPO checks pool chemicals at least twice a day and record for future records.

May 24, 2024

Permit/Opening

Score: 942 violations

19 - adequate turnover rate

Regulation: 511-3-5-.07(1)(a) - (a) the equipment for a swimming pool shall be of adequate size to turn over the entire pool water capacity. the turnover rate for pools constructed after the adoption of this chapter shall not exceed the sum of one and one-half times the average wat

5 ptsCorrected: NoRepeat: No

Current turnover rate at 13.3 hrs according to flow meter

24 - piping identified and marked

Regulation: 511-3-5-.08(6) - (6) all piping shall be marked with directional arrows as necessary to determine flow direction. all piping in the equipment room shall be permanently identified by its use and the pool and or aquatic feature it serves.

1 ptsCorrected: NoRepeat: No

Mark pipes with directional flow arrows.

Aug 18, 2023

Routine

Score: 991 violation

24 - piping identified and marked

Regulation: 511-3-5-.08(6) - (6) all piping shall be marked with directional arrows as necessary to determine flow direction. all piping in the equipment room shall be permanently identified by its use and the pool and or aquatic feature it serves.

1 ptsCorrected: NoRepeat: No

Mark pipes with directional flow arrows.

May 31, 2023

Permit/Opening

Score: 1000 violations