Savannah, Chatham County

Country Inn & Suites Southside Savannah

11317 ABERCORN ST SAVANNAH, GA 31419

Tourist
Latest score
94
Feb 26, 2026
City
Savannah
County
Chatham
Inspections
3

Score history

Inspection scores over time for this facility.

Inspection history

Georgia inspection history is score-based, with violations grouped under each recorded inspection.

Feb 26, 2026

Routine

Score: 942 violations

28 - beds, mattresses, mattress pads, springs, frames, pillows, and bed coverings clean; vermin free and in good condition; bed linen properly supplied, changed and laundered

Regulation: 511-6-2-.14(6) - bed, bedding, and linens

4 ptsCorrected: YesRepeat: Yes

Observed stain on mattress cover in room 310. Observed stain on mattress pad in room 301. Observed stain on mattress in room 102.

COS: PIC removed all soiled linens and replaced with clean ones. PIC shall have mattresses out of use until stains have been treated. CA: Washable mattress pads or covers shall be used on all mattresses. Beds, mattresses, springs, slats, mattress pads, mattress and bed coverings, pillow and pillow covers shall be clean and free from vermin

25 - floors, walls, ceilings, windows, doors clean, and in good repair; appropriate for location and operation

Regulation: 511-6-2-.14(1) - floors, walls, and ceilings

2 ptsCorrected: NoRepeat: No

Observed dip in flooring in room 202 adjacent to corner of bed. Observed unsteady and movable floor next to the AC unit in room 202. Observed framing of door for room 214 to have ripped weather seal and uneven surface. Observed room 214 to have a hole in wall adjacent to front door.

RCA: PIC shall not use room 202 until repairs have been completed. The Health Authority shall be contacted and shall inspect room 202 when repairs are completed. CA: Floors, walls, ceilings. windows, doors and all other appurtenances shall be of sound construction, properly maintained in good repair and shall be kept clean

Jun 25, 2025

Routine

Score: 903 violations

1 - adequate, approved, permitted, protected potable water supply; no cross connection or back siphonage

Regulation: 511-6-2-.07(2) - water supply and sanitizing

5 ptsCorrected: NoRepeat: No

Observed water temperatures exceeding 120F in rooms: 217 (122F), 218 (124F), 219 (126F), 220 (124F).

RCA: Hot water in all guest rooms shall not exceed 120F

28 - beds, mattresses, mattress pads, springs, frames, pillows, and bed coverings clean; vermin free and in good condition; bed linen properly supplied, changed and laundered

Regulation: 511-6-2-.14(6) - bed, bedding, and linens

4 ptsCorrected: NoRepeat: Yes

Observed staining to the mattress in room 305.

RCA: Washable mattress pads or covers shall be used on all mattresses. Beds, mattresses, springs, slats, mattress pads, mattress and bed coverings, pillow and pillow covers shall be clean and free from vermin

15 - ice from approved source; properly handled, supplied and stored; equipment approved/clean

Regulation: 511-6-2-.07(8) - ice supply

1 ptsCorrected: NoRepeat: No

Observed build-up on the interior baffle of the ice machines on the first and thirds floors.

RCA: PIC shall ensure ice machines are cleaned at a frequency to prevent excessive build-up on the baffle

Dec 3, 2024

Routine

Score: 942 violations

28 - beds, mattresses, mattress pads, springs, frames, pillows, and bed coverings clean; vermin free and in good condition; bed linen properly supplied, changed and laundered

Regulation: 511-6-2-.14(6) - bed, bedding, and linens

4 ptsCorrected: NoRepeat: No

Observed a black substance on the top of the bedding in room 201 and 215. Observed staining on the mattress in room 201 and 204. Observed small red and purple staining on pillows in rooms 204 and 215. Observed food crumbs on the mattress cover in room 215. Observed yellow staining on mattress cover in room 204

16 - toilet/lavatory/bathing facility fixtures and rooms clean and maintained; properly lighted, clearly marked, proper signage, and all in good repair

Regulation: 511-6-2-.08(4) - toilet facilities-cleaning and maintenance

2 ptsCorrected: NoRepeat: No

Observed staining on tub surface in rooms 201 and 204. Observed a red substance growing in the corner of the shower and a black moldlike substance on the wall of the shower in room 330