Wilmington Island, Chatham County

CA Bucaneer Trace Owner

55 E DEERWOOD RD SAVANNAH, GA 31410

Pool
Latest score
100
Mar 10, 2026
City
Wilmington Island
County
Chatham
Inspections
6

Score history

Inspection scores over time for this facility.

Inspection history

Georgia inspection history is score-based, with violations grouped under each recorded inspection.

Mar 10, 2026

Permit/Opening

Score: 1000 violations
No violations recorded for this inspection.

May 9, 2025

Permit/Opening

Score: 1000 violations
No violations recorded for this inspection.

Jun 27, 2024

Re-inspection

Score: 942 violations

21 - cyanuric acid level not exceeding maximum

Regulation: 511-3-5-.17(4) - (4) stabilizer (if used) cyanuric acid,ppm ideal: 30-50 maximum: 90 comments: if stabilizer is: too high: - may reduce chlorine efficacy too low: - chlorine residual rapidly destroyed by sunlight note: stabilizer is not needed in indoor or br

4 ptsCorrected: NoRepeat: Yes

Observed cyanuric acid to read above the maximum 90ppm (read: hi).

RCA: 511-3-5-.17(4) - (4) Stabilizer (if used) Cyanuric acid, ppm Ideal: 30-50 Maximum: 90 Comments: If stabilizer is: Too High: - May reduce chlorine efficacy Too Low: - Chlorine Residual rapidly destroyed by sunlight Note: Stabilizer is not needed in indoor.

16 - pool deck: maintained, unobstructed and clean

Regulation: 511-3-5-.06(1)(g) - (g) a minimum four foot deck width shall be provided on the sides and rear of any diving equipment or waterslide stairs. a deck clearance of forty-eight inches shall be provided around all deck equipment.

2 ptsCorrected: YesRepeat: Yes

Observed pool furniture (lounge chairs) on narrow deck end of pool to be maximum within three feet of edge of water.

CA: CPO rearranged furniture to allow for four feet of unobstructed walkways around pool edge.

Mar 28, 2024

Permit/Opening

Score: 746 violations

2 - self-closing / self-latching gates

Regulation: 511-3-5-.18(11)(h) - (h) access gates shall also comply with the requirements of this rule and shall be equipped to accommodate a locking device. barrier gates shall open away from the pool in facilities constructed after adoption of this chapter. pedestrian access gates

15 ptsCorrected: NoRepeat: No

Both entry gates have nearly a 30-second delay of closing before latching. CA: PIC shall contact gate company to eliminate the delay. Gates shall be shelf-latching and self-closing.

7 - ph between 7.2 and 7.8

Regulation: 511-3-5-.23(5)(b) - (b) during operation, the ph is less than the minimum or more than the maximum levels allowed in dph rule 511-3-5-.l7.

15 ptsCorrected: NoRepeat: No

Observed pH to read lower than the allowed 7.2 (pH=6.6). CA: CPO indicated that chemicals are currently being shipped. Pool shall remain closed until all chemicals are within the appropriate range.

21 - cyanuric acid level not exceeding maximum

Regulation: 511-3-5-.17(4) - (4) stabilizer (if used) cyanuric acid,ppm ideal: 30-50 maximum: 90 comments: if stabilizer is: too high: - may reduce chlorine efficacy too low: - chlorine residual rapidly destroyed by sunlight note: stabilizer is not needed in indoor or br

4 ptsCorrected: NoRepeat: No

Observed cyanuric acid to read above the maximum 90ppm (read: hi).

26 - gauge(s) in proper location; sight glass installed

Regulation: 511-3-5-.09(9)(a) - (a) the pump vacuum gauge shall be installed as close to the suction side of the pump as possible while still maintaining an accurate reading.

4 ptsCorrected: NoRepeat: No

Observed pressure gauge to read 35psi. CA: Pressure shall remain below 20psi. Back wash to clean sand or replace a misfunctioning gauge.

16 - pool deck: maintained, unobstructed and clean

Regulation: 511-3-5-.06(1)(i) - (i) a four foot minimum continuous unobstructed deck, which may include the coping, shall be provided around at least 50 percent or more of a spa.

2 ptsCorrected: NoRepeat: No

Observed pool furniture on one end of pool to be within three feet of edge of water. CA: Rearrange furniture to allow for four feet of unobstructed walkways around pool edge.

37 - other violations of the chapter

1 ptsCorrected: NoRepeat: No

Observed alkalinity to read below the minimum 60 ppm (alk: 55ppm). CA: Alkalinity shall range between 60ppm-120ppm.

Jun 12, 2023

Permit/Opening

Score: 1000 violations
No violations recorded for this inspection.

Jun 8, 2023

Permit/Opening

Score: 851 violation

6 - proper disinfectant level

Regulation: .17((1)(c) - proper disinfectant level

15 ptsCorrected: NoRepeat: No

Observed free chlorine to be reading 14.0. RCA: .17((1)(c) - Proper disinfectant level (c) Free Chlorine level in pools using cyanuric acid or a stabilized chlorine product; Minimum 2.0 Ideal 2.0-5.0 Maximum 10.0