ACWORTH, Cherokee County

Brookstone

4832 HWY 92 APT 1109 ACWORTH, GA 30102

Pool
Latest score
100
Mar 3, 2026
City
ACWORTH
County
Cherokee
Inspections
6

Score history

Inspection scores over time for this facility.

Inspection history

Georgia inspection history is score-based, with violations grouped under each recorded inspection.

Mar 3, 2026

Routine

Score: 1000 violations
No violations recorded for this inspection.

Jul 11, 2025

Routine

Score: 776 violations

19 - adequate turnover rate

Regulation: 511-3-5-.07(1)(a) - (a) the equipment for a swimming pool shall be of adequate size to turn over the entire pool water capacity. the turnover rate for pools constructed after the adoption of this chapter shall not exceed the sum of one and one-half times the average wat

5 ptsCorrected: NoRepeat: No

Observed flowmeter not working. Must replace the flowmeter.

36 - daily recordkeeping: water testing and self inspection performed

Regulation: 511-3-5-.22(12) - (12) a safety self-inspection shall be conducted daily by the trained operator or responsible person and documented on a log sheet.

5 ptsCorrected: NoRepeat: No

Must check pH and chlorine twice a day and the logs must be maintained onsite.

21 - cyanuric acid level not exceeding maximum

Regulation: 511-3-5-.17(4) - (4) stabilizer (if used) cyanuric acid,ppm ideal: 30-50 maximum: 90 comments: if stabilizer is: too high: - may reduce chlorine efficacy too low: - chlorine residual rapidly destroyed by sunlight note: stabilizer is not needed in indoor or br

4 ptsCorrected: NoRepeat: No

Cyanuric acid is greater than 100ppm. Must be below 90ppm.

26 - gauge(s) in proper location; sight glass installed

Regulation: 511-3-5-.07(4)(a) - (a) a pressure or vacuum gauge or other means of indicating system condition shall be provided in the circulation system in an easily readable location.

4 ptsCorrected: NoRepeat: No

Must effluent pressure gauge on the return line.

35 - operator facility inspections performed; written documentation

Regulation: 511-3-5-.22(5) - (5) the trained operator must perform a minimum of two visits weekly and be able to provide assistance whenever needed.

4 ptsCorrected: NoRepeat: No

CPO must check everything twice a week and the logs must be maintained onsite.

37 - other violations of the chapter

1 ptsCorrected: NoRepeat: No

Must provide extra set of cartridge filters.

Mar 12, 2025

Routine

Score: 912 violations

36 - daily recordkeeping: water testing and self inspection performed

Regulation: 511-3-5-.22(12) - (12) a safety self-inspection shall be conducted daily by the trained operator or responsible person and documented on a log sheet.

5 ptsCorrected: NoRepeat: No

Must check pH and chlorine twice a day and the logs must be maintained onsite.

35 - operator facility inspections performed; written documentation

Regulation: 511-3-5-.22(5) - (5) the trained operator must perform a minimum of two visits weekly and be able to provide assistance whenever needed.

4 ptsCorrected: NoRepeat: No

CPO must check everything twice a week and the logs must be maintained onsite.

Aug 26, 2024

Re-inspection

Score: 1000 violations
No violations recorded for this inspection.

Aug 14, 2024

Routine

Score: 627 violations

6 - proper disinfectant level

Regulation: .17((1)(c) - proper disinfectant level

15 ptsCorrected: NoRepeat: No

Chlorine is very high. Must be between 2 and 10ppm.

19 - adequate turnover rate

Regulation: 511-3-5-.07(1)(b) - (b) turnover rates for pools by type listed below: type

5 ptsCorrected: NoRepeat: No

Glow is at 90gpm. Must be 134gpm.

36 - daily recordkeeping: water testing and self inspection performed

Regulation: 511-3-5-.22(12) - (12) a safety self-inspection shall be conducted daily by the trained operator or responsible person and documented on a log sheet.

5 ptsCorrected: NoRepeat: No

Must check pH and chlorine twice a day and the logs must be maintained onsite.

21 - cyanuric acid level not exceeding maximum

Regulation: 511-3-5-.17(4) - (4) stabilizer (if used) cyanuric acid,ppm ideal: 30-50 maximum: 90 comments: if stabilizer is: too high: - may reduce chlorine efficacy too low: - chlorine residual rapidly destroyed by sunlight note: stabilizer is not needed in indoor or br

4 ptsCorrected: NoRepeat: No

Cyanuric acid is greater than 100ppm. Must be below 90ppm.

32 - operator training certification available onsite and approved

Regulation: 511-3-5-.22(2) - (2) the trained operator shall have a current certificate showing completion of an approved operator training course. a copy or the original certificate or documentation shall be available onsite for inspection by the health authority.

4 ptsCorrected: NoRepeat: No

Must post a copy of the CPO Certificate.

35 - operator facility inspections performed; written documentation

Regulation: 511-3-5-.22(5) - (5) the trained operator must perform a minimum of two visits weekly and be able to provide assistance whenever needed.

4 ptsCorrected: NoRepeat: No

CPO must check everything twice a week and the logs must be maintained onsite.

37 - other violations of the chapter

1 ptsCorrected: NoRepeat: No

Must fix the leak in the pump room.

Apr 11, 2024

Permit/Opening

Score: 981 violation

12 - grab/hand rails, ladders installed and secure

Regulation: 511-3-5-.06(3)(f)1. - 1. handrails, if removable, shall be installed in such a way that they cannot be removed without the use of tools.

2 ptsCorrected: NoRepeat: No

Handrails must be able to reach to the bottom step. Placed an order. By May 10, 2024, it should be installed.