Inspection history

Georgia inspection history is score-based, with violations grouped under each recorded inspection.

May 18, 2026

Permit/Opening

Score: 1000 violations
No violations recorded for this inspection.

Jul 2, 2025

Re-inspection

Score: 981 violation

12 - grab/hand rails, ladders installed and secure

Regulation: 511-3-5-.06(3)(f)1. - 1. handrails, if removable, shall be installed in such a way that they cannot be removed without the use of tools.

2 ptsCorrected: NoRepeat: Yes

Observed hand rail of pool stairs near life guard station loose / not secure. Must fix.

Jul 1, 2025

Routine

Score: 744 violations

5 - emergency phone operational and accessible

Regulation: 511-3-5-.18(10)(c ) - (c) an operable, hard-wired, conventional telephone line or continuous powered source, weatherproof emergency phone shall be permanently installed in a conspicuous location within the pool enclosure and must be readily available to bathers at all tim

15 ptsCorrected: NoRepeat: No

Observed 911 phone not working at time of inspection. This was corrected on sight and replaced with a voiceover IP phone, however, the address on file for the 911 operator is 1190 Bridgemill Ave and not 1200 Bridgemill Ave. 1190 Bridgemill Ave is the address for the clubhouse, which is too far from the pool to be acceptable as the 911 address. Must update 911 address to "1200 Bridgemill Ave Pool Phone".

28 - flow meter: appropriate range and location

Regulation: 511-3-5-.07(4)(b) - (b) a flow meter measuring the rate of flow through the filter system with an appropriate range readable in gallons per minute (gpm) and accurate within ten percent actual flow shall be provided. the flow indicator shall be capable of measuring from

5 ptsCorrected: NoRepeat: No

Observed flow meters in pump room A broken and unable to read turnover rate. Must fix flow meters.

17 - skimmers/gutters maintained and operable

Regulation: 511-3-5-.11(3)(d) - (d) each skimmer shall have a weir that adjusts automatically to variations in water level over a minimum range of four inches.

4 ptsCorrected: YesRepeat: No

Observed weirs missing in some skimmers. All skimmers must have a weir installed.

12 - grab/hand rails, ladders installed and secure

Regulation: 511-3-5-.06(3)(f)1. - 1. handrails, if removable, shall be installed in such a way that they cannot be removed without the use of tools.

2 ptsCorrected: NoRepeat: No

Observed hand rail of pool stairs near life guard station loose / not secure. Must fix.

May 8, 2025

Permit/Opening

Score: 1000 violations
No violations recorded for this inspection.

Aug 15, 2024

Re-inspection

Score: 1000 violations
No violations recorded for this inspection.

Aug 14, 2024

Routine

Score: 802 violations

7 - ph between 7.2 and 7.8

Regulation: 511-3-5-.17(2) - (2) chemical values: ph

15 ptsCorrected: NoRepeat: No

Observed a pH of 8.0. The pH must be between 7.2-7.8

19 - adequate turnover rate

Regulation: 511-3-5-.07(1)(a) - (a) the equipment for a swimming pool shall be of adequate size to turn over the entire pool water capacity. the turnover rate for pools constructed after the adoption of this chapter shall not exceed the sum of one and one-half times the average wat

5 ptsCorrected: NoRepeat: No

Observed a turnover rate of 550 GPM. The required turnover rate for this pool is 645 GPM.

May 9, 2024

Permit/Opening

Score: 1000 violations
No violations recorded for this inspection.

Jul 25, 2023

Routine

Score: 1000 violations
No violations recorded for this inspection.