Aug 28, 2025
Routine
28 - flow meter: appropriate range and location
Regulation: 511-3-5-.07(4)(b) - (b) a flow meter measuring the rate of flow through the filter system with an appropriate range readable in gallons per minute (gpm) and accurate within ten percent actual flow shall be provided. the flow indicator shall be capable of measuring from
Must replace the flow meter.
36 - daily recordkeeping: water testing and self inspection performed
Regulation: 511-3-5-.22(12) - (12) a safety self-inspection shall be conducted daily by the trained operator or responsible person and documented on a log sheet.
No written documentation of daily self-inspetions at facility. (12) A safety self-inspection shall be conducted daily by the trained operator or responsible person and documented on a log sheet.