Holly Springs, Cherokee County

Fox Creek

106 FOX CREEK DR WOODSTOCK, GA 30188

Pool
Latest score
100
Mar 18, 2026
City
Holly Springs
County
Cherokee
Inspections
6

Score history

Inspection scores over time for this facility.

Inspection history

Georgia inspection history is score-based, with violations grouped under each recorded inspection.

Mar 18, 2026

Permit/Opening

Score: 1000 violations
No violations recorded for this inspection.

Jul 31, 2025

Routine

Score: 951 violation

28 - flow meter: appropriate range and location

Regulation: 511-3-5-.07(4)(b) - (b) a flow meter measuring the rate of flow through the filter system with an appropriate range readable in gallons per minute (gpm) and accurate within ten percent actual flow shall be provided. the flow indicator shall be capable of measuring from

5 ptsCorrected: NoRepeat: No

Flow meter stuck - repair/replace

Apr 9, 2025

Permit/Opening

Score: 991 violation

37 - other violations of the chapter

1 ptsCorrected: NoRepeat: Yes

No Baby Changing stations in restrooms - Install diaper changing stations in both restrooms.

Jul 2, 2024

Routine

Score: 884 violations

28 - flow meter: appropriate range and location

Regulation: 511-3-5-.07(4)(b) - (b) a flow meter measuring the rate of flow through the filter system with an appropriate range readable in gallons per minute (gpm) and accurate within ten percent actual flow shall be provided. the flow indicator shall be capable of measuring from

5 ptsCorrected: NoRepeat: No

Flow meter was reading about 80GPM which is the lowest reading on the meter -Meter does not appear to be appropriately sized for system. -Achieve a flow rate of 129GPM or greater to meet turnover rates for this pool.

511-3-5-.07(4)(b) - (b) A flow meter measuring the rate of flow through the filter system with an appropriate range readable in gallons per minute (GPM) and accurate within ten percent actual flow shall be provided. The flow indicator shall be capable of measuring from (b) A flow meter measuring the rate of flow through the filter system with an appropriate range readable in gallons per minute (GPM) and accurate within ten percent actual flow shall be provided. The flow indicator shall be capable of measuring from one-half to at least one and one-half times the design flow rate. The gauge shall be located after the filtering equipment and in such location on the return line, so as to measure the total amount of water returning to the pool according to the manufacturer’s installation specifications.

36 - daily recordkeeping: water testing and self inspection performed

Regulation: 511-3-5-.22(9) - (9) water testing frequency. the trained operator or responsible person shall collect water samples from the water in the pool for monitoring. an in-line sampling port may be used for water held in reservoirs. the water quality testing frequency shal

5 ptsCorrected: NoRepeat: No

No current daily testing logs on-site. (Only CPO 2X Weekly Logs) Pools shall be tested twice daily for pH and chlorine, weekly for alkalinity, monthly for hardness, and twice monthly for cyanuric acid.

511-3-5-.22(9) - (9) Water Testing Frequency. The trained operator or responsible person shall collect water samples from the water in the pool for monitoring. An in-line sampling port may be used for water held in reservoirs. The water quality testing frequency shal (9) Water Testing Frequency. The trained operator or responsible person shall collect water samples from the water in the pool for monitoring. An in-line sampling port may be used for water held in reservoirs. The water quality testing frequency shall be as follows:

34 - inspection report placed in public view

Regulation: 511-3-5-.23(3)(d) - (d) the operator shall receive a copy of the inspection and place it in a location protected from the weather and in public view as designated by the health authority.

1 ptsCorrected: NoRepeat: No

Most Recent inspection report not posted -Post most recent copy of inspection report. 511-3-5-.23(3)(d) - (d) The operator shall receive a copy of the inspection and place it in a location protected from the weather and in public view as designated by the health authority. (d) The operator shall receive a copy of the inspection and place it in a location protected from the weather and in public view as designated by the health authority.

37 - other violations of the chapter

1 ptsCorrected: NoRepeat: No

No Baby Changing stations in restrooms - Install diaper changing stations in both restrooms.

May 1, 2024

Permit/Opening

Score: 1000 violations
No violations recorded for this inspection.

Jul 17, 2023

Routine

Score: 951 violation

19 - adequate turnover rate

Regulation: 511-3-5-.07(1)(a) - (a) the equipment for a swimming pool shall be of adequate size to turn over the entire pool water capacity. the turnover rate for pools constructed after the adoption of this chapter shall not exceed the sum of one and one-half times the average wat

5 ptsCorrected: NoRepeat: No

Turnover rate not able to be observed as the flow meter was not working. Must fix or replace.