Mar 18, 2026
Permit/Opening
235 MILTON OVERLOOK PASS WOODSTOCK, GA 30188
Inspection scores over time for this facility.
Georgia inspection history is score-based, with violations grouped under each recorded inspection.
Permit/Opening
Routine
Permit/Opening
Routine
Regulation: 511-3-5-.07(4)(b) - (b) a flow meter measuring the rate of flow through the filter system with an appropriate range readable in gallons per minute (gpm) and accurate within ten percent actual flow shall be provided. the flow indicator shall be capable of measuring from
Flow meter stuck - Repair/replace
Regulation: 511-3-5-.22(9) - (9) water testing frequency. the trained operator or responsible person shall collect water samples from the water in the pool for monitoring. an in-line sampling port may be used for water held in reservoirs. the water quality testing frequency shal
No onsite daily logs - maintain logs onsite of testing twice daily for chlorine and pH, weekly for alkalinity, monthly for hardness and twice monthly for cyanuric acid.
Regulation: 511-3-5-.17(4) - (4) stabilizer (if used) cyanuric acid,ppm ideal: 30-50 maximum: 90 comments: if stabilizer is: too high: - may reduce chlorine efficacy too low: - chlorine residual rapidly destroyed by sunlight note: stabilizer is not needed in indoor or br
Cyanuric Acid levels greater than 100 - Reduce cyanuric acid levels to less than 90ppm
Permit/Opening
Turn over rate must be at or around 180. During inspection it show 80 GPM.
Routine
Regulation: 511-3-5-.22(9) - (9) water testing frequency. the trained operator or responsible person shall collect water samples from the water in the pool for monitoring. an in-line sampling port may be used for water held in reservoirs. the water quality testing frequency shal
Chemical must be checked twice a day by volunteer and CPO must check twice a week and make necessary adjustments.