HAMPTON, Clayton County

Waterpointe Community Association

12195 COLDSTREAM CT HAMPTON, GA 30228

Pool
Latest score
100
May 14, 2026
City
HAMPTON
County
Clayton
Inspections
5

Score history

Inspection scores over time for this facility.

Inspection history

Georgia inspection history is score-based, with violations grouped under each recorded inspection.

May 14, 2026

Permit/Opening

Score: 1000 violations
No violations recorded for this inspection.

May 29, 2024

Re-inspection

Score: 885 violations

14 - vacuum line protected

Regulation: 511-3-5-.10(7) - (7) the vacuum line shall be protected with a self-closing, self-latching fitting that complies with the current iampo sps 4- special use suction fitting for swimming pools, spas and hot tubs.

5 ptsCorrected: NoRepeat: No

Missing vacuum line plug. Shall be protected/closed

12 - grab/hand rails, ladders installed and secure

Regulation: 511-3-5-.06(3)(f)1. - 1. handrails, if removable, shall be installed in such a way that they cannot be removed without the use of tools.

2 ptsCorrected: NoRepeat: No

Tops step at ladder is in disrepair. Must be temporarily repaired or repaired prior to opening. Must be permanently repaired prior to next pool season

16 - pool deck: maintained, unobstructed and clean

Regulation: 511-3-5-.06(1)(l) - (l) open joints or gaps larger than three-sixteenths inch wide or with vertical elevations exceeding 1/4 inches shall be rectified using appropriate fillers. construction joints where pool coping meets the decks shall be watertight and shall not allo

2 ptsCorrected: NoRepeat: No

Cracks observed in deck and in coping and in pool shell near steps. Shall be maintained

22 - signs: peak occupancy/pool/spa/signs legible and in clearview

Regulation: 511-3-5-.18(13)(c) - (c) a sign shall be posted stating the hours of operation in clear view near the entrance and shall state the theoretical peak occupancy.

2 ptsCorrected: NoRepeat: No

Sign saying pool occupancy shall be posted. Advised to obtain sign saying pool occupancy or max occupancy

37 - other violations of the chapter

1 ptsCorrected: NoRepeat: No

Pool shell in need of repair and resurfacing. Shall be maintained. Pool shell shall be repaired and resurfaced prior to pool season in order to obtain permitting inspection

May 22, 2024

Permit/Opening

Score: 707 violations

6 - proper disinfectant level

Regulation: .17(1)(a)(b) - proper disinfectant level

15 ptsCorrected: NoRepeat: No

Chlorine level is too low at 1ppm. Shall be min of 2ppm

10 - pump: approved, maintained and operating

Regulation: 511-3-5-.09(1) - (1) sizing. a pump and motor shall be provided for circulation of the pool and spa water. performance of all pumps shall meet or exceed the conditions of flow required for filtering and cleaning (if applicable) the filters against the total dynamic h

15 ptsCorrected: NoRepeat: No

Flow is at 185 should be min of 230 with 10% reduction factor, 248 is required. Min flow rate shall be maintained by pump

14 - vacuum line protected

Regulation: 511-3-5-.10(7) - (7) the vacuum line shall be protected with a self-closing, self-latching fitting that complies with the current iampo sps 4- special use suction fitting for swimming pools, spas and hot tubs.

5 ptsCorrected: NoRepeat: No

Missing vacuum line plug. Shall be protected/closed

19 - adequate turnover rate

Regulation: 511-3-5-.07(1)(a) - (a) the equipment for a swimming pool shall be of adequate size to turn over the entire pool water capacity. the turnover rate for pools constructed after the adoption of this chapter shall not exceed the sum of one and one-half times the average wat

5 ptsCorrected: NoRepeat: No

Flow rate reading 185 GPM; pool has previously been capable of obtaining a flow rate of 230 GPM

16 - pool deck: maintained, unobstructed and clean

Regulation: 511-3-5-.06(1)(l) - (l) open joints or gaps larger than three-sixteenths inch wide or with vertical elevations exceeding 1/4 inches shall be rectified using appropriate fillers. construction joints where pool coping meets the decks shall be watertight and shall not allo

2 ptsCorrected: NoRepeat: No

Cracks observed in deck and in coping and in pool shell near steps. Shall be maintained

22 - signs: peak occupancy/pool/spa/signs legible and in clearview

Regulation: 511-3-5-.18(13)(c) - (c) a sign shall be posted stating the hours of operation in clear view near the entrance and shall state the theoretical peak occupancy.

2 ptsCorrected: NoRepeat: No

Sign saying pool occupancy shall be posted. Advised to obtain sign saying pool occupancy or max occupancy

37 - other violations of the chapter

1 ptsCorrected: NoRepeat: No

Pool shell in need of repair and resurfacing. Shall be maintained. Pool shell shall be repaired and resurfaced prior to pool season in order to obtain permitting inspection

Jun 13, 2023

Permit/Opening

Score: 1000 violations
No violations recorded for this inspection.

May 19, 2023

Permit/Opening

Score: 833 violations

1 - barrier: pool enclosed/fencing in compliance

Regulation: 511-3-5-.18(11)(b) - (b) openings in the barrier shall not allow passage of a four inch diameter sphere.

15 ptsCorrected: NoRepeat: No

Bottom of entrance gate above 4 inches measuring 5 inches. Advised to repair gate.

4 - water clarity: main drains clearly visible

Regulation: 511-3-5-.07(1)(e ) - (e) water clarity shall be maintained. when standing at the pool's edge at the deep end, the main drain suction outlet covers or a four inch by four inch square marker tile in contrasting color shall be clearly visible. when standing at a spa's e

15 ptsCorrected: NoRepeat: No

Observed cloudy pool on deep end of pool. Advised to fix pool chemistry.

22 - signs: peak occupancy/pool/spa/signs legible and in clearview

Regulation: 511-3-5-.18(13)(c) - (c) a sign shall be posted stating the hours of operation in clear view near the entrance and shall state the theoretical peak occupancy.

2 ptsCorrected: NoRepeat: No

No pool occupancy sign posted. Advised to obtain sign & diving sign.