STOCKBRIDGE, Clayton County

Villas at Hannover Phase I

7305 HANNOVER PKWY STOCKBRIDGE, GA 30281

Pool
Latest score
76
Jun 8, 2026
City
STOCKBRIDGE
County
Clayton
Inspections
4

Score history

Inspection scores over time for this facility.

Inspection history

Georgia inspection history is score-based, with violations grouped under each recorded inspection.

Jun 8, 2026

Permit/Opening

Score: 764 violations

1 - barrier: pool enclosed/fencing in compliance

Regulation: 511-3-5-.23(5)(g) - (g) failure to provide and maintain a barrier to inhibit unauthorized access to the outdoor facility when required.

15 ptsCorrected: YesRepeat: No

Observed gate propped open upon arrival. COS- gate was closed

6 - proper disinfectant level

Regulation: .17(1)(a)(b) - proper disinfectant level

15 ptsCorrected: NoRepeat: No

Observed Cl measuring at 0ppm. Advised to adjust

19 - adequate turnover rate

Regulation: 511-3-5-.07(1)(a) - (a) the equipment for a swimming pool shall be of adequate size to turn over the entire pool water capacity. the turnover rate for pools constructed after the adoption of this chapter shall not exceed the sum of one and one-half times the average wat

5 ptsCorrected: NoRepeat: No

Observed pool not meeting adequate turnover rate. Advised to adjust

17 - skimmers/gutters maintained and operable

Regulation: 511-3-5-.11(3)(d) - (d) each skimmer shall have a weir that adjusts automatically to variations in water level over a minimum range of four inches.

4 ptsCorrected: NoRepeat: No

Observed weirs missing in pool. Advised to install

Jun 6, 2025

Permit/Opening

Score: 1000 violations
No violations recorded for this inspection.

Jun 17, 2024

Permit/Opening

Score: 852 violations

2 - self-closing / self-latching gates

Regulation: 511-3-5-.18(11)(h) - (h) access gates shall also comply with the requirements of this rule and shall be equipped to accommodate a locking device. barrier gates shall open away from the pool in facilities constructed after adoption of this chapter. pedestrian access gates

15 ptsCorrected: NoRepeat: Yes

Observed entry gate to the pool not self-closing, self-latching. Advised PIC Access gates shall also comply with the requirements of this Rule and shall be equipped to accommodate a locking device.

11 - appropriate lifesaving equipment present

Regulation: 511-3-5-.18(10)(b) - (b) a minimum one-fourth inch diameter throwing rope one and one-half times the maximum width of the pool or fifty feet in length, whichever is less, to which has been firmly attached a ring buoy with an outside diameter of approximately fifteen inch

15 ptsCorrected: YesRepeat: No

Observed no rope on ring buoy. Advised PIC A minimum one-fourth inch diameter throwing rope one and one-half times the maximum width of the pool or fifty feet in length, whichever is less, to which has been firmly attached a ring buoy with an outside diameter of approximately fifteen inches or a similar flotation device which is U.S. Coast Guard approved. COS: Had PIC place sufficient rope on ring buoy.

Aug 14, 2023

Permit/Opening

Score: 786 violations

2 - self-closing / self-latching gates

Regulation: 511-3-5-.18(11)(h) - (h) access gates shall also comply with the requirements of this rule and shall be equipped to accommodate a locking device. barrier gates shall open away from the pool in facilities constructed after adoption of this chapter. pedestrian access gates

15 ptsCorrected: NoRepeat: No

Observed gate not self closing and not self latching. Advised to repair

7 - ph between 7.2 and 7.8

Regulation: 511-3-5-.23(5)(b) - (b) during operation, the ph is less than the minimum or more than the maximum levels allowed in dph rule 511-3-5-.l7.

15 ptsCorrected: NoRepeat: No

Observed pool pH above 7.8. Advised to adjust

11 - appropriate lifesaving equipment present

Regulation: 511-3-5-.18(10)(a) - (a) a light, strong pole not less than twelve feet long including body hook.

15 ptsCorrected: NoRepeat: No

Observed shepard's hook is disrepair. Advised to repair

17 - skimmers/gutters maintained and operable

Regulation: 511-3-5-.11(3)(d) - (d) each skimmer shall have a weir that adjusts automatically to variations in water level over a minimum range of four inches.

4 ptsCorrected: NoRepeat: No

Observed weir not working properly.

12 - grab/hand rails, ladders installed and secure

Regulation: 511-3-5-.06(3)(f)1. - 1. handrails, if removable, shall be installed in such a way that they cannot be removed without the use of tools.

2 ptsCorrected: NoRepeat: No

Observed loose railings. Advised to correct

30 - deck/rinse shower maintained

Regulation: 511-3-5-.18(17) - (17) a minimum of one rinse shower shall be provided on the pool deck of all public pools and spas. water used for rinse showers may be at ambient temperature.

1 ptsCorrected: NoRepeat: No

Observed deck showers not working. Advised to repair