STOCKBRIDGE, Clayton County

The Retreat 138

3384 MT. ZION RD STOCKBRIDGE, GA 30281

Pool
Latest score
96
Jun 2, 2026
City
STOCKBRIDGE
County
Clayton
Inspections
4

Score history

Inspection scores over time for this facility.

Inspection history

Georgia inspection history is score-based, with violations grouped under each recorded inspection.

Jun 2, 2026

Permit/Opening

Score: 961 violation

15 - depth and no diving markers, step marking; installed and contrasting

Regulation: 511-3-5-.18(3)(h) - (h) depth markers number and letters shall be tile and four inches minimum in height. numbers shall be of contrasting color to the background on which they are applied.

4 ptsCorrected: NoRepeat: No

Need FT in 4 inch high lettering at all depth intervals. Must submit modification application and fee by 12 pm today. Must have FT in 4 inch high lettering by next inspection at all depth intervals.

Aug 28, 2024

Routine

Score: 972 violations

12 - grab/hand rails, ladders installed and secure

Regulation: 511-3-5-.06(3)(f)1. - 1. handrails, if removable, shall be installed in such a way that they cannot be removed without the use of tools.

2 ptsCorrected: NoRepeat: Yes

Observed one loose grab rail at time of inspection. Advised PIC Handrails, if removable, shall be installed in such a way that they cannot be removed without the use of tools.

37 - other violations of the chapter

1 ptsCorrected: NoRepeat: Yes

Observed surface of pool in need of resurfacing multiple areas of pool interior throughout pool. Advised PIC to have the interior portion of pool resurfaced.

May 14, 2024

Re-inspection

Score: 972 violations

12 - grab/hand rails, ladders installed and secure

Regulation: 511-3-5-.06(3)(f)1. - 1. handrails, if removable, shall be installed in such a way that they cannot be removed without the use of tools.

2 ptsCorrected: NoRepeat: Yes

Observed one loose grab rail at time of inspection. Advised PIC Handrails, if removable, shall be installed in such a way that they cannot be removed without the use of tools.

37 - other violations of the chapter

1 ptsCorrected: NoRepeat: Yes

Observed surface of pool in need of resurfacing multiple areas of pool interior throughout pool. Advised PIC to have the interior portion of pool resurfaced

May 7, 2024

Permit/Opening

Score: 709 violations

2 - self-closing / self-latching gates

Regulation: 511-3-5-.18(11)(h) - (h) access gates shall also comply with the requirements of this rule and shall be equipped to accommodate a locking device. barrier gates shall open away from the pool in facilities constructed after adoption of this chapter. pedestrian access gates

15 ptsCorrected: NoRepeat: No

Observed gate not self-latching, self-closing at close range. Advised PIC Access gates shall also comply with the requirements of this Rule and shall be equipped to accommodate a locking device. Barrier gates shall open away from the pool in facilities constructed after adoption of this chapter. Pedestrian access gates shall be self-closing and have a self-latching device. Gates other than pedestrian access gates shall have a self-latching device. Where the release mechanism of the self latching.

7 - ph between 7.2 and 7.8

Regulation: 511-3-5-.17(2) - (2) chemical values: ph

15 ptsCorrected: NoRepeat: No

Observed pH measuring 7.0. Advised PIC pH shall be pH 7.2 7.4-7.6 7.8.

19 - adequate turnover rate

Regulation: 511-3-5-.07(1)(a) - (a) the equipment for a swimming pool shall be of adequate size to turn over the entire pool water capacity. the turnover rate for pools constructed after the adoption of this chapter shall not exceed the sum of one and one-half times the average wat

5 ptsCorrected: NoRepeat: No

Observed inadequate turnover rate, above minimum required 6 hour turnover rate. Advised PIC This system shall be designed to give the proper turnover rate based on the manufacturer's recommended maximum pressure flow of the filter in dirty media condition of the filter, immediately prior to cleaning the filter.

28 - flow meter: appropriate range and location

Regulation: 511-3-5-.07(4)(b) - (b) a flow meter measuring the rate of flow through the filter system with an appropriate range readable in gallons per minute (gpm) and accurate within ten percent actual flow shall be provided. the flow indicator shall be capable of measuring from

5 ptsCorrected: NoRepeat: No

Observed one of two flow meters for the pool, in disrepair, active leak observed, measuring 0 GPM. Advised PIC The flow indicator shall be capable of measuring from one-half to at least one and one-half times the design flow rate.

12 - grab/hand rails, ladders installed and secure

Regulation: 511-3-5-.06(3)(f)1. - 1. handrails, if removable, shall be installed in such a way that they cannot be removed without the use of tools.

2 ptsCorrected: NoRepeat: No

Observed one loose grab rail at time of inspection. Advised PIC Handrails, if removable, shall be installed in such a way that they cannot be removed without the use of tools.

22 - signs: peak occupancy/pool/spa/signs legible and in clearview

Regulation: 511-3-5-.18(13)(c) - (c) a sign shall be posted stating the hours of operation in clear view near the entrance and shall state the theoretical peak occupancy.

2 ptsCorrected: NoRepeat: No

Observed no theoretical peak occupancy signage and pool hours at entry gate. Advised PIC A sign shall be posted stating the hours of operation in clear view near the entrance and shall state the theoretical peak occupancy.

22 - signs: peak occupancy/pool/spa/signs legible and in clearview

Regulation: 511-3-5-.18(12)(a) - (a) the words "no diving" and the universal international symbol for “no diving” shall be permanently visible at the edge of the deck for water five feet in depth or less, placed only on the deck beside the depth markers, and shall conform to that ou

2 ptsCorrected: NoRepeat: No

Observed no, 'No Diving' markers at depth markers on pool decking area throughout pool deck area. The words "No Diving" and the universal international symbol for “NO DIVING” shall be permanently visible at the edge of the deck for water five feet in depth or less, placed only on the deck beside the depth markers, and shall conform to that outlined for depth markers in subsections (3)(a) thru (h) above.

37 - other violations of the chapter

1 ptsCorrected: NoRepeat: Yes

Observed surface of pool in need of resurfacing multiple areas of pool interior throughout pool. Advised PIC to have the interior portion of pool resurfaced

37 - other violations of the chapter

1 ptsCorrected: NoRepeat: No

Observed pressure gauge on filters in disrepair, cannot determine pressure. Advised PIC Influent and effluent pressure gauges (if both are present in the system) shall have the capability to measure.