Jun 5, 2026
Routine
4 - water clarity: main drains clearly visible
Water was turbid, no main drain visible.
5 - emergency phone operational and accessible
Regulation: 511-3-5-.18(10)(c ) - (c) an operable, hard-wired, conventional telephone line or continuous powered source, weatherproof emergency phone shall be permanently installed in a conspicuous location within the pool enclosure and must be readily available to bathers at all tim
Emergency phone not operable. Attempted to connect several times but was never able to reach 911.
6 - proper disinfectant level
Chlorine of 12ppm above acceptable range of 2-10ppm.
7 - ph between 7.2 and 7.8
pH observed at 7, maintain between 7.2-7.8.
8 - chemical feeder operational and approved
Regulation: 511-3-5-.23(5)(c ) - (c) the pump, automatic disinfectant equipment, or other equipment necessary for continuous filtration and disinfection of the swimming pool, spa, or recreational water park attraction is not working or is unable to maintain adequate turnover rate.
Leasing office employee stated that pump was broken at time of inspection.
9 - filter: approved, maintained and operating
Leasing office employee stated that pump was broken at time of inspection.
10 - pump: approved, maintained and operating
Regulation: 511-3-5-.23(5)(c ) - (c) the pump, automatic disinfectant equipment, or other equipment necessary for continuous filtration and disinfection of the swimming pool, spa, or recreational water park attraction is not working or is unable to maintain adequate turnover rate.
Leasing office employee stated that pump was broken at time of inspection.
17 - skimmers/gutters maintained and operable
Skimmers were not pulling water.
34 - inspection report placed in public view
No inspection report observable. Employee was notified to post one in view.