KENNESAW, Cobb County

1800 AT BARRETT LAKES THE - LOWER

1800 BARRETT LAKES BLVD NW KENNESAW, GA 30144-4567

Pool
Latest score
100
Jun 13, 2025
City
KENNESAW
County
Cobb
Inspections
7

Score history

Inspection scores over time for this facility.

Inspection history

Georgia inspection history is score-based, with violations grouped under each recorded inspection.

Jun 13, 2025

Re-inspection

Score: 1000 violations
No violations recorded for this inspection.

Jun 11, 2025

Permit/Opening

Score: 851 violation

11 - appropriate lifesaving equipment present

Regulation: 511-3-5-.18(10)(b) - (b) a minimum one-fourth inch diameter throwing rope one and one-half times the maximum width of the pool or fifty feet in length, whichever is less, to which has been firmly attached a ring buoy with an outside diameter of approximately fifteen inch

15 ptsCorrected: NoRepeat: No

Ensure life ring has rope attached

Jul 12, 2024

Re-inspection

Score: 961 violation

17 - skimmers/gutters maintained and operable

Regulation: 511-3-5-.11(3)(d) - (d) each skimmer shall have a weir that adjusts automatically to variations in water level over a minimum range of four inches.

4 ptsCorrected: NoRepeat: No

skimmers not pulling

Jul 10, 2024

Routine

Score: 793 violations

7 - ph between 7.2 and 7.8

Regulation: 511-3-5-.23(5)(b) - (b) during operation, the ph is less than the minimum or more than the maximum levels allowed in dph rule 511-3-5-.l7.

15 ptsCorrected: NoRepeat: Yes

pH observed below 7, maintain between 7.2-7.8

17 - skimmers/gutters maintained and operable

Regulation: 511-3-5-.11(3)(d) - (d) each skimmer shall have a weir that adjusts automatically to variations in water level over a minimum range of four inches.

4 ptsCorrected: NoRepeat: No

skimmers not pulling/ missing weirs

12 - grab/hand rails, ladders installed and secure

Regulation: 511-3-5-.06(3)(f)1. - 1. handrails, if removable, shall be installed in such a way that they cannot be removed without the use of tools.

2 ptsCorrected: NoRepeat: Yes

Grab rail extremely loose, fix ASAP

May 21, 2024

Permit/Opening

Score: 874 violations

28 - flow meter: appropriate range and location

5 ptsCorrected: NoRepeat: No

Flow meter bulb stuck. CA: Repair/replace.

32 - operator training certification available onsite and approved

Regulation: 511-3-5-.22(2) - (2) the trained operator shall have a current certificate showing completion of an approved operator training course. a copy or the original certificate or documentation shall be available onsite for inspection by the health authority.

4 ptsCorrected: NoRepeat: No

No proof of valid CPO. CA: Valid CPO required.

12 - grab/hand rails, ladders installed and secure

2 ptsCorrected: NoRepeat: No
  1. Both handrails loose. CA:Tighten.

22 - signs: peak occupancy/pool/spa/signs legible and in clearview

2 ptsCorrected: NoRepeat: No

Peak occupancy sign not posted. CA: Post peak occupancy.

Jul 14, 2023

Re-inspection

Score: 1000 violations
No violations recorded for this inspection.

Jun 12, 2023

Permit/Opening

Score: 852 violations

6 - proper disinfectant level

15 ptsCorrected: NoRepeat: No

No chlorine detected. CA: 2-10ppm Cl required.

7 - ph between 7.2 and 7.8

15 ptsCorrected: NoRepeat: No

pH too low at 7.0. CA: 7.2-7.8 pH required.