Jun 13, 2025
Re-inspection
1800 BARRETT LAKES BLVD NW KENNESAW, GA 30144-4567
Inspection scores over time for this facility.
Georgia inspection history is score-based, with violations grouped under each recorded inspection.
Re-inspection
Permit/Opening
Regulation: 511-3-5-.18(10)(b) - (b) a minimum one-fourth inch diameter throwing rope one and one-half times the maximum width of the pool or fifty feet in length, whichever is less, to which has been firmly attached a ring buoy with an outside diameter of approximately fifteen inch
Ensure life ring has rope attached
Re-inspection
Regulation: 511-3-5-.11(3)(d) - (d) each skimmer shall have a weir that adjusts automatically to variations in water level over a minimum range of four inches.
skimmers not pulling
Routine
Regulation: 511-3-5-.23(5)(b) - (b) during operation, the ph is less than the minimum or more than the maximum levels allowed in dph rule 511-3-5-.l7.
pH observed below 7, maintain between 7.2-7.8
Regulation: 511-3-5-.11(3)(d) - (d) each skimmer shall have a weir that adjusts automatically to variations in water level over a minimum range of four inches.
skimmers not pulling/ missing weirs
Regulation: 511-3-5-.06(3)(f)1. - 1. handrails, if removable, shall be installed in such a way that they cannot be removed without the use of tools.
Grab rail extremely loose, fix ASAP
Permit/Opening
Flow meter bulb stuck. CA: Repair/replace.
Regulation: 511-3-5-.22(2) - (2) the trained operator shall have a current certificate showing completion of an approved operator training course. a copy or the original certificate or documentation shall be available onsite for inspection by the health authority.
No proof of valid CPO. CA: Valid CPO required.
Peak occupancy sign not posted. CA: Post peak occupancy.
Re-inspection
Permit/Opening
No chlorine detected. CA: 2-10ppm Cl required.
pH too low at 7.0. CA: 7.2-7.8 pH required.