Mableton, Cobb County

PREMIER APARTMENTS - POOL

7200 PREMIER LN AUSTELL, GA 30168-7763

Pool
Latest score
72
Aug 16, 2024
City
Mableton
County
Cobb
Inspections
5

Score history

Inspection scores over time for this facility.

Inspection history

Georgia inspection history is score-based, with violations grouped under each recorded inspection.

Aug 16, 2024

Routine

Score: 728 violations

5 - emergency phone operational and accessible

Regulation: 511-3-5-.18(10)(c ) - (c) an operable, hard-wired, conventional telephone line or continuous powered source, weatherproof emergency phone shall be permanently installed in a conspicuous location within the pool enclosure and must be readily available to bathers at all tim

15 ptsCorrected: NoRepeat: No

Observed the phone cutting in and out and unable to connect. CA 511-3-5-.18(10)(c ) - (c) An operable, hard-wired, conventional telephone line or continuous powered source, weatherproof emergency phone shall be permanently installed in a conspicuous location within the pool enclosure and must be readily available to bathers at all tim (c) An operable, hard-wired, conventional telephone line or continuous powered source, weatherproof emergency phone shall be permanently installed in a conspicuous location within the pool enclosure and must be readily available to bathers at all times. The emergency phone shall be capable of connecting to 911 and electronically transferring an automatic number identification and automatic locator identification of the pool emergency phone to the public safety answering point, if available. A 911 sign or the names and phone numbers of the nearest available police, fire, ambulance service or rescue unit shall be posted nearby.

6 - proper disinfectant level

Regulation: .17(1)(a)(b) - proper disinfectant level

15 ptsCorrected: NoRepeat: No

Observed no chlorine in the pool. CA .17(1)(a)(b) - Proper disinfectant level (1) Disinfectant Levels (a) Free chlorine,ppm in pools not using cyanuric acid or a stabilized chlorine compound use (b),1.-5. (b) All public pools except as listed below: Minimum 1.0 Ideal 1.0-3.0 Maximum 10.0

11 - appropriate lifesaving equipment present

15 ptsCorrected: NoRepeat: Yes

Observed no shepherd's hook or U.S. Coast Guard approved life ring along pool deck. C/A: Provide life ring and shepherd's hook.

11 - appropriate lifesaving equipment present

Regulation: 511-3-5-.18(10)(b) - (b) a minimum one-fourth inch diameter throwing rope one and one-half times the maximum width of the pool or fifty feet in length, whichever is less, to which has been firmly attached a ring buoy with an outside diameter of approximately fifteen inch

15 ptsCorrected: NoRepeat: No

Observed the life ring without a rope. CA 511-3-5-.18(10)(b) - (b) A minimum one-fourth inch diameter throwing rope one and one-half times the maximum width of the pool or fifty feet in length, whichever is less, to which has been firmly attached a ring buoy with an outside diameter of approximately fifteen inch (b) A minimum one-fourth inch diameter throwing rope one and one-half times the maximum width of the pool or fifty feet in length, whichever is less, to which has been firmly attached a ring buoy with an outside diameter of approximately fifteen inches or a similar flotation device which is U.S. Coast Guard approved.

18 - combined chlorine level 0.4 ppm or less

Regulation: 511-3-5-.17(1) - (1) disinfectant levels (a) free chlorine, ppm in pools not using cyanuric acid or a stabilized chlorine compound use (b),1.-5.

5 ptsCorrected: NoRepeat: No

Observed no chlorine levels in the pool. CA 511-3-5-.17(1) - (1) Disinfectant Levels (a) Free chlorine, ppm in pools not using cyanuric acid or a stabilized chlorine compound use (b),1.-5. (1) Disinfectant Levels (a) Free chlorine, ppm in pools not using cyanuric acid or a stabilized chlorine compound use (b),1.-5.

17 - skimmers/gutters maintained and operable

Regulation: 511-3-5-.11(3)(d) - (d) each skimmer shall have a weir that adjusts automatically to variations in water level over a minimum range of four inches.

4 ptsCorrected: NoRepeat: No

Observed the baskets in skimmers full of debris. CA 511-3-5-.11(3)(d) - (d) Each skimmer shall have a weir that adjusts automatically to variations in water level over a minimum range of four inches. (d) Each skimmer shall have a weir that adjusts automatically to variations in water level over a minimum range of four inches.

12 - grab/hand rails, ladders installed and secure

Regulation: 511-3-5-.06(3)(f)1. - 1. handrails, if removable, shall be installed in such a way that they cannot be removed without the use of tools.

2 ptsCorrected: NoRepeat: No

Observed both of the single handle bars loose, need to be tightened. CA 511-3-5-.06(3)(f)1. - 1. Handrails, if removable, shall be installed in such a way that they cannot be removed without the use of tools.

  1. Handrails, if removable, shall be installed in such a way that they cannot be removed without the use of tools.

22 - signs: peak occupancy/pool/spa/signs legible and in clearview

Regulation: 511-3-5-.18(13)(c) - (c) a sign shall be posted stating the hours of operation in clear view near the entrance and shall state the theoretical peak occupancy.

2 ptsCorrected: NoRepeat: No

Observed the following signage not posted: pool occupancy, pool hours, pool risks, and "WARNING NO LIFEGUARD ON DUTY-RISK OF DROWNING SUPERVISE CHILDERN CLOSELY". C/A: Provide and post all required pool signage. Required pool signage document provided.

May 24, 2024

Re-inspection

Score: 1000 violations
No violations recorded for this inspection.

May 8, 2024

Permit/Opening

Score: 714 violations

7 - ph between 7.2 and 7.8

15 ptsCorrected: NoRepeat: No

maintain pH at 7.2-7.8

14 - vacuum line protected

5 ptsCorrected: NoRepeat: No

Install self-closing, self-latching vacuum line cover.

28 - flow meter: appropriate range and location

5 ptsCorrected: NoRepeat: No

Unclog flow meter

20 - return inlets maintained

4 ptsCorrected: NoRepeat: No

Install eyeball covers on inlets.

Jul 11, 2023

Re-inspection

Score: 648 violations

11 - appropriate lifesaving equipment present

Regulation: 511-3-5-.23(5)(h) - (h) absence of required lifesaving equipment on the deck or an emergency phone;

15 ptsCorrected: NoRepeat: No

Observed no shepherd's hook or U.S. Coast Guard approved life ring along pool deck. C/A: Provide life ring and shepherd's hook.

14 - vacuum line protected

Regulation: 511-3-5-.10(7) - (7) the vacuum line shall be protected with a self-closing, self-latching fitting that complies with the current iampo sps 4- special use suction fitting for swimming pools, spas and hot tubs.

5 ptsCorrected: NoRepeat: No

Observed suction outlets covers missing. C/A: Provide outlet covers.

15 - depth and no diving markers, step marking; installed and contrasting

4 ptsCorrected: NoRepeat: No

Observed missing "No Diving" markers. C/A: Provide "No Diving" markers.

17 - skimmers/gutters maintained and operable

Regulation: 511-3-5-.11(3)(g) - (g) the skimmer equalizer lines shall be protected by an approved cover/grated with a flow rating equal the maximum system flow divided by the number of skimmers in the system or the maximum flow rating of the skimmer, whichever is greater.

4 ptsCorrected: NoRepeat: No

Observed skimmer covers missing for each skimmer. C/A: Provide approved cover for all skimmers.

17 - skimmers/gutters maintained and operable

Regulation: 511-3-5-.11(3)(d) - (d) each skimmer shall have a weir that adjusts automatically to variations in water level over a minimum range of four inches.

4 ptsCorrected: NoRepeat: No

Observer skimmer weirs missing in all pool skimmers. C/A: Provide weir for each skimmer.

20 - return inlets maintained

Regulation: 511-3-5-.10(1)(a) - (a) pools shall use wall or floor inlets that are adequate in design, number and location to provide adequate mixing.

4 ptsCorrected: NoRepeat: No

Observed return inlet covers missing. C/A: Provide covers for inlets.

16 - pool deck: maintained, unobstructed and clean

Regulation: 511-3-5-.06(1)(l) - (l) open joints or gaps larger than three-sixteenths inch wide or with vertical elevations exceeding 1/4 inches shall be rectified using appropriate fillers. construction joints where pool coping meets the decks shall be watertight and shall not allo

2 ptsCorrected: NoRepeat: No

Observed cracks and uneven surface along pool deck. C/A: Repair to be smooth and safe.

22 - signs: peak occupancy/pool/spa/signs legible and in clearview

2 ptsCorrected: NoRepeat: No

Observed the following signage not posted: pool occupancy, pool hours, pool risks, and "WARNING NO LIFEGUARD ON DUTY-RISK OF DROWNING SUPERVISE CHILDERN CLOSELY". C/A: Provide and post all required pool signage. Required pool signage document provided.

May 17, 2023

Routine

Score: 6310 violations

8 - chemical feeder operational and approved

Regulation: 511-3-5-.16(1) - (1) disinfectant equipment and chemical feeders, such as flow-through chemical feeders, electrolytic chemical generators, mechanical chemical feeders, chemical feed pumps, and automated controllers shall comply with the requirements of nsf standard 5

15 ptsCorrected: NoRepeat: No

Observed about 10 chlorine tablets in skimmer basket.

11 - appropriate lifesaving equipment present

Regulation: 511-3-5-.23(5)(h) - (h) absence of required lifesaving equipment on the deck or an emergency phone;

15 ptsCorrected: NoRepeat: No

Observed shepherd's hook and U.S. Coast Guard Approved Life Ring Missing.

14 - vacuum line protected

Regulation: 511-3-5-.10(7) - (7) the vacuum line shall be protected with a self-closing, self-latching fitting that complies with the current iampo sps 4- special use suction fitting for swimming pools, spas and hot tubs.

5 ptsCorrected: NoRepeat: No

Observed suction outlets covers missing.

15 - depth and no diving markers, step marking; installed and contrasting

Regulation: 511-3-5-.18(3)(h) - (h) depth markers number and letters shall be tile and four inches minimum in height. numbers shall be of contrasting color to the background on which they are applied.

4 ptsCorrected: NoRepeat: No

Observed Universal No Diving Markers Missing.

17 - skimmers/gutters maintained and operable

Regulation: 511-3-5-.11(3)(g) - (g) the skimmer equalizer lines shall be protected by an approved cover/grated with a flow rating equal the maximum system flow divided by the number of skimmers in the system or the maximum flow rating of the skimmer, whichever is greater.

4 ptsCorrected: NoRepeat: No

Observed covers to all skimmers missing.

20 - return inlets maintained

Regulation: 511-3-5-.10(1)(c )1.ii. - (ii) the fitting shall not constitute a hazard to the user.

4 ptsCorrected: NoRepeat: No

Observed return inlet cover missing.

16 - pool deck: maintained, unobstructed and clean

Regulation: 511-3-5-.06(1)(l) - (l) open joints or gaps larger than three-sixteenths inch wide or with vertical elevations exceeding 1/4 inches shall be rectified using appropriate fillers. construction joints where pool coping meets the decks shall be watertight and shall not allo

2 ptsCorrected: NoRepeat: No

Observed numerous cracks and uneven surface on pool deck.

22 - signs: peak occupancy/pool/spa/signs legible and in clearview

Regulation: 511-3-5-.18(13)(c) - (c) a sign shall be posted stating the hours of operation in clear view near the entrance and shall state the theoretical peak occupancy.

2 ptsCorrected: NoRepeat: No

Observed the following signage not posted: 1) Pool Occupancy, 2) Pool Risks 3) WARNING NO LIFEGUARD ON DUTY-RISK OF DROWNING SUPERVISE CHILDERN CLOSELY 3) Emergency 911 with property address.

37 - other violations of the chapter

1 ptsCorrected: NoRepeat: No

Observed cracks in pool plaster.

37 - other violations of the chapter

1 ptsCorrected: NoRepeat: No

Observed overgrowth of vegetation on pool deck.