Georgia inspection history is score-based, with violations grouped under each recorded inspection.

May 30, 2025

Permit/Opening

Score: 1000 violations
No violations recorded for this inspection.

May 15, 2025

Permit/Opening

Score: 851 violation

6 - proper disinfectant level

Regulation: .17((1)(c) - proper disinfectant level

15 ptsCorrected: NoRepeat: No

Observed chlorine at 16.5ppm

C/A: chlorine shall be maintained between 2-10ppm

Aug 14, 2024

Routine

Score: 961 violation

20 - return inlets maintained

Regulation: 511-3-5-.10(1)(c )1.ii. - (ii) the fitting shall not constitute a hazard to the user.

4 ptsCorrected: NoRepeat: No

Observed return inlet over missing; the one closest to the 3ft grab/handrail.

May 15, 2024

Permit/Opening

Score: 1000 violations
No violations recorded for this inspection.

May 8, 2024

Permit/Opening

Score: 802 violations

7 - ph between 7.2 and 7.8

Regulation: 511-3-5-.17(2) - (2) chemical values: ph

15 ptsCorrected: NoRepeat: No

Observed pH at 7.0ppm. C/A: pH shall be maintained between 7.2 and 7.8ppm

28 - flow meter: appropriate range and location

Regulation: 511-3-5-.07(4)(b) - (b) a flow meter measuring the rate of flow through the filter system with an appropriate range readable in gallons per minute (gpm) and accurate within ten percent actual flow shall be provided. the flow indicator shall be capable of measuring from

5 ptsCorrected: NoRepeat: No

Observed flow meter with a range not high enough to accurately display the flow rate. C/A: The flow indicator shall be capable of measuring from one-half to at least one and one-half times the design flow rate.

Aug 9, 2023

Routine

Score: 1000 violations
No violations recorded for this inspection.

May 16, 2023

Permit/Opening

Score: 1000 violations
No violations recorded for this inspection.