ATLANTA, DeKalb County

BRADFORD SQUARE CONDOMINIUMS

2560 BRADFORD SQUARE, N.E. ATLANTA, GA 30345

Pool
Latest score
70
Jun 10, 2026
City
ATLANTA
County
DeKalb
Inspections
12

Score history

Inspection scores over time for this facility.

Inspection history

Georgia inspection history is score-based, with violations grouped under each recorded inspection.

Jun 10, 2026

Routine

Score: 705 violations

6 - proper disinfectant level

Regulation: 511-3-5-.23(5)(a) - (a) during operation, disinfectant levels are less than the minimum level specified in dph rule 511-3-5-.17. if the level of the disinfectant used is not specified in dph rule 511-3-5-.17, the disinfectant must be approved and kept at levels determin

15 ptsCorrected: YesRepeat: Yes

Chorine must be maintained between 3.0 & 10.0 ppm. The 1st reading was 0.84 and the 2nd reading was 9.24 ppm.

19 - adequate turnover rate

Regulation: 511-3-5-.07(1)(a) - (a) the equipment for a swimming pool shall be of adequate size to turn over the entire pool water capacity. the turnover rate for pools constructed after the adoption of this chapter shall not exceed the sum of one and one-half times the average wat

5 ptsCorrected: NoRepeat: Yes

An adequate turnover rate would have a flowmeter reading of 79 at the minimum. I observed 40 gpm, which isn't sufficient.

36 - daily recordkeeping: water testing and self inspection performed

Regulation: 511-3-5-.22(12) - (12) a safety self-inspection shall be conducted daily by the trained operator or responsible person and documented on a log sheet.

5 ptsCorrected: NoRepeat: Yes

The log sheet was very inconsistent with either 1 reading a day or no readings for an entire day.

17 - skimmers/gutters maintained and operable

Regulation: 511-3-5-.11(3)(g) - (g) the skimmer equalizer lines shall be protected by an approved cover/grated with a flow rating equal the maximum system flow divided by the number of skimmers in the system or the maximum flow rating of the skimmer, whichever is greater.

4 ptsCorrected: YesRepeat: Yes

Skimmers were not circulating or maintained initially, but this was corrected after the CPO arrived.

37 - other violations of the chapter

1 ptsCorrected: NoRepeat: Yes

Pool surface and sidewalls must be free of dirt, debris, or sediment.

May 4, 2026

Permit/Opening

Score: 1000 violations
No violations recorded for this inspection.

Jul 1, 2025

Routine

Score: 981 violation

16 - pool deck: maintained, unobstructed and clean

2 ptsCorrected: NoRepeat: No

Pool deck was obstructed

Jun 30, 2025

Routine

Score: 749 violations

6 - proper disinfectant level

15 ptsCorrected: NoRepeat: No

pH was way below required levels at 0.26

8 - chemical feeder operational and approved

15 ptsCorrected: NoRepeat: No

No CPO onsite

10 - pump: approved, maintained and operating

15 ptsCorrected: NoRepeat: No

No CPO onsite

28 - flow meter: appropriate range and location

5 ptsCorrected: NoRepeat: No

Flow meter/adequate turnover rate was below 79 gpm

15 - depth and no diving markers, step marking; installed and contrasting

4 ptsCorrected: NoRepeat: No

Depth markers were not secure in the concrete

15 - depth and no diving markers, step marking; installed and contrasting

4 ptsCorrected: NoRepeat: No

Depth markers were not secure in the concrete

15 - depth and no diving markers, step marking; installed and contrasting

4 ptsCorrected: NoRepeat: No

Depth markers not were not secure in the concrete

34 - inspection report placed in public view

1 ptsCorrected: NoRepeat: No

Previous inspection reports not in view

37 - other violations of the chapter

1 ptsCorrected: NoRepeat: No

EAP not filled out

May 1, 2025

Permit/Opening

Score: 942 violations

19 - adequate turnover rate

5 ptsCorrected: NoRepeat: No

13-190(a)- Observed pool turnover rate time measuring at 7 hours. CA: The equipment shall be operated continuously on a twenty-four (24) hour basis to obtain the minimum required number of four (4) turnovers per day, or one turnover every six (6) hours (pools).

37 - other violations of the chapter

1 ptsCorrected: NoRepeat: No

13-202(i)- Observed pool facility without a filled out and complete Emergency action plan (EAP). CA: Each pool facility shall have in place a departmentally approved EAP. The EAP shall include a "Chemical emergency plan", an "emergency crisis plan", an "emergency evacuation plan", a "water rescue and injury emergency plan", a "drill procedures for emergency situations", and other emergency plans and safety programs.

Jun 25, 2024

Routine

Score: 942 violations

19 - adequate turnover rate

5 ptsCorrected: NoRepeat: Yes

13-190(a): The equipment shall be operating continuously on a 24-hour basis to maintain a minimum of 4 required turnovers per day. Observed flow meter at 0, should be at least 80.

37 - other violations of the chapter

1 ptsCorrected: NoRepeat: No

13-189(a)(5): All pools shall be kept free from sediment, dirt, or debris by frequently brushing and vacuuming the bottom and sidewalls. Visible scum shall be removed immediately. Observed staining at the bottom of the pool.

May 30, 2024

Permit/Opening

Score: 1000 violations
No violations recorded for this inspection.

Apr 26, 2024

Permit/Opening

Score: 764 violations

2 - self-closing / self-latching gates

Regulation: 511-3-5-.18(11)(h) - (h) access gates shall also comply with the requirements of this rule and shall be equipped to accommodate a locking device. barrier gates shall open away from the pool in facilities constructed after adoption of this chapter. pedestrian access gates

15 ptsCorrected: NoRepeat: No

I observed the gate did not self close or latch properly.

6 - proper disinfectant level

Regulation: .17(1)(a)(b) - proper disinfectant level

15 ptsCorrected: NoRepeat: No

I observed chlorine at 1.0 needs to be 3.0

19 - adequate turnover rate

Regulation: 511-3-5-.07(1)(a) - (a) the equipment for a swimming pool shall be of adequate size to turn over the entire pool water capacity. the turnover rate for pools constructed after the adoption of this chapter shall not exceed the sum of one and one-half times the average wat

5 ptsCorrected: NoRepeat: No

I observed a 25 gpm turnover rate needs to be 60.

32 - operator training certification available onsite and approved

Regulation: 511-3-5-.22(2) - (2) the trained operator shall have a current certificate showing completion of an approved operator training course. a copy or the original certificate or documentation shall be available onsite for inspection by the health authority.

4 ptsCorrected: NoRepeat: No

I did not observed documentation of the cpo

Aug 22, 2023

Routine

Score: 912 violations

19 - adequate turnover rate

5 ptsCorrected: NoRepeat: Yes

13-190(A) - EQUIPMENT SHALL BE OPERATED CONTINUOUSLY ON A TWENTY-FOUR HOUR BASIS TO OBTAIN THE MINIMUM REQUIRED NUMBER OF ONE TURNOVER EVERY 6 HOURS. MINIMUM TURNOVER IS ~80 GPM. OBSERVED FLOWMETER READING 45GPM

17 - skimmers/gutters maintained and operable

4 ptsCorrected: YesRepeat: No

13-190(a) - ALL CIRCULATION SYSTEM COMPONENTS SHALL FUNCTION PROPERLY AND BE MAINTAINED IN A CLEAN CONDITION. OBSERVED SKIMMERS NOT OPERABLE AND FULL OF DEBRIS

Jul 13, 2023

Re-inspection

Score: 951 violation

19 - adequate turnover rate

5 ptsCorrected: NoRepeat: No

13-190(a)- There should be an adequate turnover rate with a minimum of 80 gpm. Turnover was 45 gpm, during the inspection

Jul 11, 2023

Routine

Score: 746 violations

6 - proper disinfectant level

15 ptsCorrected: NoRepeat: No

13-189(C)(1) - FREE CHLORINE MUST BE KEPT BETWEEN 3PPM AND 10 PPM. OBSERVED CHLORINE AT 0.58 PPM

7 - ph between 7.2 and 7.8

15 ptsCorrected: NoRepeat: No

13-189(c)(1) - POOL PH LEVELS SHALL BE MAINTAINED BETWEEN 7.2 - 7.8

19 - adequate turnover rate

5 ptsCorrected: NoRepeat: No

13-190(a)- There should be an adequate turnover rate with a minimum of 80 gpm. It was 20 gpm, during the inspection

36 - daily recordkeeping: water testing and self inspection performed

5 ptsCorrected: NoRepeat: No

13-189(C)(1) - POOL SHALL BE TESTED FOR THE DISINFECTANT LEVEL AND PH AT LEAST 2 TIMES EACH DAY. POOL WAS NOT BEING TESTED DAILY

37 - other violations of the chapter

1 ptsCorrected: NoRepeat: No

13-187(C) - OPERATING PERMIT SHALL BE FRAMED AND DISPLAYED IN A CONSPICUOUS PLACE AS CLOSE TO THE POOL ENTRANCE AS POSSIBLE

37 - other violations of the chapter

1 ptsCorrected: NoRepeat: No

13-189(C)(1) - A DPD TEST KIT SHALL BE PROVIDED AND USED

Jun 2, 2023

Permit/Opening

Score: 991 violation

37 - other violations of the chapter

1 ptsCorrected: NoRepeat: No

#37 : Violation: Pool surface with discoloration and residue from deck repair material. Recommendation: Resurface pool surface.