Jun 3, 2026
Followup
2-2D - adequate handwashing facilities supplied & accessible
Regulation: 511-6-1.07(3)(b) - hand drying provision (pf)
Observed no paper towels at hand sink. COS: Paper towels were restocked. C/A: 511-6-1.07(3)(b) - Hand Drying Provision (Pf) (b) Hand Drying Provision. Each handwashing sink or group of adjacent handwashing sinks shall be provided with:
- Individual, disposable towels; Pf
8-2B - toxic substances properly identified, stored, used
Regulation: 511-6-1.07(6)(g) - chemical sanitizers, criteria (p)
Observed the sanitizer at the 3 compartment sink reading 400+ ppm Quats. COS: sanitizer sink was remade to read 200 ppm Quats. Advised to use test strips while preparing solutions. C/A: 511-6-1.07(6)(g) - Chemical Sanitizers, Criteria (P) (g) Chemical Sanitizers, Criteria. Chemical sanitizers, including chemical sanitizing solutions generated on-site, and other chemical antimicrobials applied to food-contact surfaces shall:
-
Meet requirements specified in 40 CFR 180.940 Tolerance exemptions for active and inert ingredients for use in antimicrobial formulations (Food-contact surface sanitizing solutions) P, or
-
Meet the requirements as specified in 40 CFR 180.2020 Pesticide Chemicals Not Requiring a Tolerance or Exemption from Tolerance-Non-food determinations. P