Brookhaven, DeKalb County

DRESDEN FOREST APARTMENTS

1526 DRESDEN DR ATLANTA, GA 30319

Pool
Latest score
95
May 29, 2026
City
Brookhaven
County
DeKalb
Inspections
8

Score history

Inspection scores over time for this facility.

Inspection history

Georgia inspection history is score-based, with violations grouped under each recorded inspection.

May 29, 2026

Permit/Opening

Score: 951 violation

19 - adequate turnover rate

5 ptsCorrected: NoRepeat: No

13-205(b)(1) The equipment shall be operated continuously on a 24 hour basis to obtain the minimum required number of 1 turnover every 6 hours for standard pools. Turnover rate was low. Flow meters read ~100 gpm instead of the required 277.77 gpm.

Aug 27, 2025

Routine

Score: 1000 violations
No violations recorded for this inspection.

Jul 22, 2025

Permit/Opening

Score: 1000 violations
No violations recorded for this inspection.

Jul 18, 2024

Routine

Score: 884 violations

28 - flow meter: appropriate range and location

5 ptsCorrected: NoRepeat: No

13-190(a)(7) Adequately sized flow meter shall be installed on the return line. Observed that flow meter was stuck at 120 gpm. Flow rate should be greater than 277 gpm which cannot be determined with the current flow meter.

17 - skimmers/gutters maintained and operable

4 ptsCorrected: NoRepeat: No

13-196 (a)(4) Each skimmer shall have a properly designed and operating weir or other departmentally approved means of skimming effectively. Observed that one of the weirs were missing from its skimmer.

22 - signs: peak occupancy/pool/spa/signs legible and in clearview

2 ptsCorrected: NoRepeat: Yes

13-202(m): Safety rules and regulations shall be easily readable and shall be conspicuously posted in the pool area. The lettering shall be a minimum of 3/4" except as otherwise noted. Observed that pool rules signage was missing several required statements, explicitly "Bathers must wear bathing attire".

37 - other violations of the chapter

1 ptsCorrected: NoRepeat: No

13-188(a) Pool surfaces shall have no cracks or open joints; shall be constructed of approved materials. Vinyl liners and rough abrasive materials prohibited. Observed that pool surfaces appear to be worn down inside of pool as well as around pool area. Depth marker on shallow end chipping.

Jun 4, 2024

Permit/Opening

Score: 932 violations

19 - adequate turnover rate

5 ptsCorrected: NoRepeat: No

13-190(a): The equipment shall be operated continuously on a 24-hour basis to obtain the minimum required number of 4 turnovers per day. Observed that pool flow meter indicated that pool was not functioning at a rate to obtain the proper number of turnovers. GPM minimum is 277 and was observed at 100.

22 - signs: peak occupancy/pool/spa/signs legible and in clearview

2 ptsCorrected: NoRepeat: No

13-202(m): Safety rules and regulations shall be easily readable and shall be conspicuously posted in the pool area. The lettering shall be a minimum of 3/4" except as otherwise noted. Observed that pool rules signage was missing several required statements, explicitly "Bathers must wear bathing attire".

Jul 26, 2023

Routine

Score: 802 violations

6 - proper disinfectant level

15 ptsCorrected: YesRepeat: No

13-189(c)(1): The free chlorine residual in all parts of the pool shall be maintained at a concentration between 3-10ppm. Observed free-chlorine at 1.5 ppm. Corrected on site to 3.23.

28 - flow meter: appropriate range and location

5 ptsCorrected: NoRepeat: Yes

13-190(a)(7): An adequately sized flow meter shall be installed on the return line. Observed meter that maxed at 120 gpm. Flow rate should be greater than 277 gpm which cannot be determined with the current flow meter.

Jun 16, 2023

Permit/Opening

Score: 902 violations

28 - flow meter: appropriate range and location

5 ptsCorrected: NoRepeat: No

13-190(a)(7): An adequately sized flow meter shall be installed on the return line. Observed meter that maxed at 120 gpm. Flow rate should be greater than 277 gpm.

36 - daily recordkeeping: water testing and self inspection performed

5 ptsCorrected: NoRepeat: No

13-189(c)(4): Pool water shall be tested for disinfectant and pH at least 2 times daily. Observed log with missing days, some days only tested once.

Jun 15, 2023

Permit/Opening

Score: 853 violations

14 - vacuum line protected

5 ptsCorrected: NoRepeat: No

13-190(a)(6): Wall-mounted type vacuum systems are prohibited. Imminent health hazard. Observed vacuum line intact. Could not verify that the line had been previously filled.

28 - flow meter: appropriate range and location

5 ptsCorrected: NoRepeat: No

13-190(a)(7): An adequately sized flow meter shall be installed on the return line. Observed meter that maxed at 120 gpm. Flow rate should be greater than 277 gpm.

36 - daily recordkeeping: water testing and self inspection performed

5 ptsCorrected: NoRepeat: No

13-189(c)(4): Pool water shall be tested for disinfectant and pH at least 2 times daily. Observed log with missing days.