May 12, 2025
Permit/Opening
19 - adequate turnover rate
13-190(a): The equipment shall be operated continuously on a twenty-four (24) hour basis to obtain the minimum required number of one turnover every four (4) hours (pools with diving board or water feature). Observed flowrate at 1000gpm. Minimum required flowrate is 1572 gpm.
15 - depth and no diving markers, step marking; installed and contrasting
13-188(d)(1): Depth markers must be at least 4 inches high with indication in feet and inches. Observation: the "ft" and "in" is observed to be less than 4 inches.
15 - depth and no diving markers, step marking; installed and contrasting
13-188(d)(2): At the shallow portions of the pool or where depths are 5"(five feet) or less shall have permanent "No Diving" in minimum two inch (2") black letters with white background. -Observed "No Diving" black letters less than two inches.