May 8, 2026

Permit/Opening

Score: 1000 violations
No violations recorded for this inspection.

Jun 27, 2025

Routine

Score: 851 violation

6 - proper disinfectant level

15 ptsCorrected: YesRepeat: No

13-189(c)(1): The free-chlorine residual shall be maintained between 3-10 ppm at all times. Observed free-chlorine at 1.6 ppm. It was corrected to 3.19ppm.

May 20, 2025

Permit/Opening

Score: 1000 violations
No violations recorded for this inspection.

Jul 11, 2024

Re-inspection

Score: 952 violations

26 - gauge(s) in proper location; sight glass installed

4 ptsCorrected: NoRepeat: No

13-193(a): Adequately sized backwash sight glass on backwash line. Observed that there was no sight glass on the main backwash line.

29 - toilets & lavatories: clean, maintained, and stocked

1 ptsCorrected: NoRepeat: No

13-201(k): At all times, an adequate supply of liquid soap, toilet paper, and paper towels shall be provided and accessible to users. Observed men's restroom hand sinks did not have soap available.

Jul 10, 2024

Routine

Score: 826 violations

1 - barrier: pool enclosed/fencing in compliance

15 ptsCorrected: YesRepeat: No

13-202(a)(1): Barrier shall not have any openings wherein a sphere 4" in diameter can pass through. Observed a gap in fencing near splash pad.

2 - self-closing / self-latching gates

15 ptsCorrected: NoRepeat: No

13-202(a)(2): Entry into pool area shall be at shallow end of pool through a self closing, self latching door or gate. Observed that main gate entrance into the pool area could not completely self close or self latch.

5 - emergency phone operational and accessible

15 ptsCorrected: YesRepeat: No

13-202(g): An operable telephone with direct 911 access installed in a conspicuous location shall be readily available at all times. Observed emergency phone was not operable.

11 - appropriate lifesaving equipment present

15 ptsCorrected: NoRepeat: No

13-202(d): Pool shall be provided with Sheppard's hook attached to a non telescopic pole. Additional sets of equipment are required for pool longer than 50'. Observed that the second Sheppard's hook for pool was not operational.

12 - grab/hand rails, ladders installed and secure

2 ptsCorrected: NoRepeat: No

13-184(e)(5): Unsecured handrails considered an imminent health hazard. Observed that ladder into pool next to slide and diving board unsecured.

29 - toilets & lavatories: clean, maintained, and stocked

1 ptsCorrected: NoRepeat: No

13-201(k): At all times, an adequate supply of liquid soap, toilet paper, and paper towels shall be provided and accessible to users. Observed men's restroom hand sinks did not have soap available.

May 23, 2024

Permit/Opening

Score: 961 violation

26 - gauge(s) in proper location; sight glass installed

4 ptsCorrected: NoRepeat: No

13-193(a) : adequately sized in -line backwash sight glass on backwash line. observed: NO sight glass was observed on the main backwash line.

Aug 10, 2023

Re-inspection

Score: 851 violation

5 - emergency phone operational and accessible

15 ptsCorrected: NoRepeat: No

13-202(g): An operable telephone with direct 911 access installed in a conspicuous location shall be readily available at all times. Observed phone could connect, but no audio could be received. Critical violation.

Aug 10, 2023

Re-inspection

Score: 1000 violations
No violations recorded for this inspection.

Aug 8, 2023

Routine

Score: 754 violations

6 - proper disinfectant level

15 ptsCorrected: NoRepeat: No

13-189(c)(1): The free-chlorine residual shall be maintained between 3-10 ppm at all times. Observed free-chlorine at 1.5 ppm.

19 - adequate turnover rate

5 ptsCorrected: NoRepeat: No

13-190(a): The equipment shall be operated to maintain the minimum required 4 turnovers/day. For a pool of 150,000 g, the minimum required flow rate is 417 gpm. Observed bobber at the bottom of meter.

17 - skimmers/gutters maintained and operable

4 ptsCorrected: NoRepeat: No

13-190(a): All circulation components shall function and be maintained in a clean condition. Observed skimmers filled with leaves from storm and one skimmer missing a cover.

29 - toilets & lavatories: clean, maintained, and stocked

1 ptsCorrected: NoRepeat: No

13-201(j): An adequately sized, covered and lined trash receptacle shall be provided in each men's and women's restroom. Observed restroom receptacles were unlined.

Jul 11, 2023

Re-inspection

Score: 1000 violations
No violations recorded for this inspection.

Jul 10, 2023

Routine

Score: 803 violations

6 - proper disinfectant level

15 ptsCorrected: NoRepeat: No

13-189(c)(1): The free-chlorine residual shall be maintained between 3-10 ppm at all times. Observed free-chlorine at 1.5 ppm.

13 - float line in position

4 ptsCorrected: NoRepeat: No

13-202(1): Float line shall be installed across pool along slope break where pools exceed 5 feet. Observed float line missing.

37 - other violations of the chapter

1 ptsCorrected: NoRepeat: No

13-202(i): Each pool shall have a departmentally approved EAP which shall include the following sections: "Chemical Emergency Evacuation Plan", "Emergency Crisis Plan", "Water Rescue and Injury Emergency Plan", "Drill Procedures for Emergency Situations" and other sections as needed. Observed EAP missing required sections.