Brookhaven, DeKalb County

ASHFORD PARK SPLASHPAD

2980 REDDING RD ATLANTA, GA 30319

Pool
Latest score
100
May 1, 2026
City
Brookhaven
County
DeKalb
Inspections
9

Score history

Inspection scores over time for this facility.

Inspection history

Georgia inspection history is score-based, with violations grouped under each recorded inspection.

May 1, 2026

Permit/Opening

Score: 1000 violations
No violations recorded for this inspection.

Apr 30, 2026

Permit/Opening

Score: 7310 violations

2 - self-closing / self-latching gates

15 ptsCorrected: NoRepeat: No

13-202(a)(2) Gate, near equipment room, not self closing.

4 - water clarity: main drains clearly visible

15 ptsCorrected: NoRepeat: No

13-189(c)(6) The water in tank is not clear. Need to be drained and refilled. Water is dark and murky.

7 - ph between 7.2 and 7.8

15 ptsCorrected: NoRepeat: No

13-189(c)(1) pH level should be between 7.2-7.8. pH was observed to be 7.0.

8 - chemical feeder operational and approved

15 ptsCorrected: NoRepeat: No

13-197(i) pH chemical feeder is not operational. Need to fix pH feeder. Need to replace feeder tube.

28 - flow meter: appropriate range and location

5 ptsCorrected: NoRepeat: No

13-190(a)(7) Flowmeter not operational. Needs repair.

36 - daily recordkeeping: water testing and self inspection performed

5 ptsCorrected: NoRepeat: No

13-202(c) Chemical log books were not provided.

29 - toilets & lavatories: clean, maintained, and stocked

1 ptsCorrected: NoRepeat: No

13-201(k) Women's bathroom needs soap.

29 - toilets & lavatories: clean, maintained, and stocked

1 ptsCorrected: NoRepeat: No

13-201(j) Both bathrooms need trashcans with lids.

37 - other violations of the chapter

1 ptsCorrected: NoRepeat: No

13-202(i) Emergency action plan not provided at the time of inspection.

37 - other violations of the chapter

1 ptsCorrected: NoRepeat: No

13-198(a) Filters were not stored within equipment cabinets. pH acid jugs were stored outside of cabinet. Both should be stored within cabinet.

Jul 24, 2024

Routine

Score: 1000 violations
No violations recorded for this inspection.

Jul 17, 2024

Re-inspection

Score: 706 violations

5 - emergency phone operational and accessible

15 ptsCorrected: NoRepeat: No

13-202(g) Emergency phone was inoperable.

6 - proper disinfectant level

15 ptsCorrected: NoRepeat: No

13-189(c)(1)-Chlorine shall be maintained at a range of 3ppm-10ppm

7 - ph between 7.2 and 7.8

15 ptsCorrected: NoRepeat: No

13-189(c)(1)-The pool shall be maintained in an alkaline condition at all times with a pH level between 7.2-7.8.

19 - adequate turnover rate

5 ptsCorrected: NoRepeat: No

Flow Meter was inoperable. Unable to detect a reading.

28 - flow meter: appropriate range and location

5 ptsCorrected: NoRepeat: No

13-190(b)(1): equipment shall be operated to obtain 1 turnover every 30 minutes. Flow meter not operational.

36 - daily recordkeeping: water testing and self inspection performed

5 ptsCorrected: NoRepeat: No

Did not have daily recordkeeping

Jul 16, 2024

Routine

Score: 854 violations

2 - self-closing / self-latching gates

15 ptsCorrected: NoRepeat: No

13-202(a)(2) both gates were not self-closing or self-latching

5 - emergency phone operational and accessible

Regulation: 511-3-5-.18(10)(c ) - (c) an operable, hard-wired, conventional telephone line or continuous powered source, weatherproof emergency phone shall be permanently installed in a conspicuous location within the pool enclosure and must be readily available to bathers at all tim

15 ptsCorrected: NoRepeat: No

13-202(g) Emergency phone was inoperable.

6 - proper disinfectant level

15 ptsCorrected: NoRepeat: No

13-189(c)(1)-Chlorine shall be maintained at a range of 3ppm-10ppm.

7 - ph between 7.2 and 7.8

15 ptsCorrected: NoRepeat: No

13-189(c)(1). The pool shall be maintained in an alkaline condition at all times with a pH level between 7.2-7.8

May 14, 2024

Permit/Opening

Score: 1000 violations
No violations recorded for this inspection.

Jun 27, 2023

Re-inspection

Score: 842 violations

6 - proper disinfectant level

15 ptsCorrected: YesRepeat: No

13-189(c)(1): Chlorine shall be maintained at a range of 3ppm-10ppm. Obs: Chlorine observed at 0.14ppm. CPO adjusted to 7.19.

30 - deck/rinse shower maintained

1 ptsCorrected: NoRepeat: No

13-201(b): If no bathroom is required, a shower with hot water range of 70-104 degrees shall be provided for each 100 men or women. Obs: Deck shower has no hot water.

Jun 26, 2023

Routine

Score: 793 violations

6 - proper disinfectant level

15 ptsCorrected: NoRepeat: No

13-189(c)(1): Chlorine shall be maintained at a range of 3ppm-10ppm. Obs: Chlorine observed to measure at 0.18ppm.

28 - flow meter: appropriate range and location

5 ptsCorrected: NoRepeat: No

13-190(b)(1): equipment shall be operated to obtain 1 turnover every 30 minutes. Obs: Flow meter not operational.

30 - deck/rinse shower maintained

1 ptsCorrected: NoRepeat: No

13-201(b): If no bathroom is required, a shower with hot water range of 70-104 degrees shall be provided for each 100 men or women. Obs: Deck shower has no hot water.

May 24, 2023

Permit/Opening

Score: 991 violation

30 - deck/rinse shower maintained

1 ptsCorrected: NoRepeat: No

13-201(b) Deck shower not functional.