3301 HENDERSON MILL RD CHAMBLEE, GA 30341
Inspection scores over time for this facility.
Georgia inspection history is score-based, with violations grouped under each recorded inspection.
Permit/Opening
Routine
13-187(c) The operating permit shall be framed and displayed in a conspicuous place as close to the pool entrance as possible such that it is easily readable by the public at all times. Observed: Pool inspections visible, but need pool permit placed next to them.
Routine
37 Other violations of the chapter. Emergency Action Plan must be displayed near phone. Includes chemical emergency evacuation plan, emergency crisis plan, drill procedures, emergencies procedures unique to the pool.
Permit/Opening
Re-inspection
Routine
13-189(c)(1) FCL shall be maintained between 3-10ppm at all times. Observation: Initial test read 1.05 ppm, after adjustments, chlorine test read above 12 ppm.
13-187(c): A copy of the pool operator's certificate shall be conspicuously displayed. Observed: No CPO certificate was present.
Permit/Opening
Re-inspection
13-190(a)(7)- Flow meter shall be operational and accurately display GPM. Flow meter not working.
13-187(c)- Current inspection shall be displayed in public view. No inspection found.
Routine
13-189(c)(1)- Pool shall maintain a pH level between 7.2-7.8.
13-190(a)(7)- Flow meter shall be operational and accurately display GPM. Flow meter not working.
13-189(c)(4)- Pool water shall be tested at least twice a day. Record shows that water has not been tested since 7/18.
13-202(m)- Pool sign must be filled out entirely to include hours and bather load.
13-187(c)- Current inspection shall be displayed in public view. NO inspection found.
13-198(a)- Equipment room shall be kept locked when no servicing is being done. Observed that the equipment room was open to bathers at time of inspection.
Permit/Opening
Observed depth markers in indicating 1/2. Informed CPO to change pool to indicate feet and inches.
Observed light and exhaust in pump room not operating. Provide exhaust fan in pump room. Informed to add baby changing station in restrooms.
Permit/Opening
Regulation: 511-3-5-.18(3)(h) - (h) depth markers number and letters shall be tile and four inches minimum in height. numbers shall be of contrasting color to the background on which they are applied.
Observed depth markers in indicating 1/2. Informed CPO to change pool to indicate feet and inches.
Regulation: 511-3-5-.06(1)(l) - (l) open joints or gaps larger than three-sixteenths inch wide or with vertical elevations exceeding 1/4 inches shall be rectified using appropriate fillers. construction joints where pool coping meets the decks shall be watertight and shall not allo
-Deck expansion joints (fill-in). -Repair broken 3 feet marker tile.
Provide baby changing station in restroom. Provide hot and cold running water in restroom.
Observed light and exhaust in pump room not operating. Provide exhaust fan in pump room.