Chamblee, DeKalb County

DECO AT 5211 (POOL)

5211 PEACHTREE BLVD ATLANTA, GA 30341

Pool
Latest score
95
Oct 2, 2025
City
Chamblee
County
DeKalb
Inspections
7

Score history

Inspection scores over time for this facility.

Inspection history

Georgia inspection history is score-based, with violations grouped under each recorded inspection.

Oct 2, 2025

Routine

Score: 951 violation

19 - adequate turnover rate

Regulation: 511-3-5-.07(1)(b) - (b) turnover rates for pools by type listed below: type

5 ptsCorrected: NoRepeat: Yes

Observed low turnover rate of 90gpm. CPO stated that the flow meter is showing a combined turnover rate for both pools. Therefore, both pools must have a combined turnover rate of 188gpm.

13-190(a): The equipment shall be operated continuously on a twenty-four (24) hour basis to obtain the minimum required number of four (4) turnovers per day, or one turnover every six (6) hours.

May 23, 2025

Re-inspection

Score: 951 violation

19 - adequate turnover rate

5 ptsCorrected: NoRepeat: Yes

Observed low turnover rate of 100gpm. CPO stated that the flow meter is showing a combined turnover rate for both pools. Therefore, both pools must have a combined turnover rate of 188gpm.

13-190(a): The equipment shall be operated continuously on a twenty-four (24) hour basis to obtain the minimum required number of four (4) turnovers per day, or one turnover every six (6) hours.

May 8, 2025

Permit/Opening

Score: 802 violations

6 - proper disinfectant level

Regulation: .17((1)(c) - proper disinfectant level

15 ptsCorrected: NoRepeat: No

Observed FCL reading of 14+ ppm which exceeds the 10ppm requirement.

CA: 13-189(c)(1)Where stabilizing agents are used, a free-chlorine residual shall be maintained at a concentration of no less than three parts per million (3ppm) at all times. The maximum stabilized or unstabilized free chlorine residual shall not exceed ten parts per million (10ppm).

Discussed with CPO to lower the FCL levels in the pool. CPO will be draining some of the water, then refilling the pool and servicing it to achieve proper FCL levels.

19 - adequate turnover rate

Regulation: 511-3-5-.07(1)(a) - (a) the equipment for a swimming pool shall be of adequate size to turn over the entire pool water capacity. the turnover rate for pools constructed after the adoption of this chapter shall not exceed the sum of one and one-half times the average wat

5 ptsCorrected: NoRepeat: Yes

An observed turnover rate of 0 GPM was recorded. A 36,000-gallon pool must have a minimum turnover rate of 100 GPM.

CA: 13-190(a) The equipment shall be operated continuously on a twenty-four (24) hour basis to obtain the minimum required number of four (4) turnovers per day, or one turnover every six (6) hours.

Aug 20, 2024

Re-inspection

Score: 951 violation

19 - adequate turnover rate

5 ptsCorrected: NoRepeat: No

13-190(a) The equipment shall be operated continuously on a twenty four hour basis to obtain the minimum required number of four turnovers per day, or one every six hours. Flow meter was not operational.

Jul 19, 2023

Re-inspection

Score: 951 violation

28 - flow meter: appropriate range and location

5 ptsCorrected: NoRepeat: Yes

13-190(a) Minimum required turnover rate every 30 mins for spas. CPO stated that the flow meter shows the combined GPM for both pools. Required GPM is 154 gpm and the current gpm is at 90 gpm. Please correct to adequate turnover rate.

Jul 18, 2023

Routine

Score: 763 violations

6 - proper disinfectant level

15 ptsCorrected: YesRepeat: No

13-189(c)(1) FCL shall be maintained between 3-10ppm at all times. Observation: Initial reading 2.35, second reading 3ppm.

28 - flow meter: appropriate range and location

5 ptsCorrected: NoRepeat: Yes

13-190(a) Minimum required turnover rate every 30 mins for spas. CPO stated that the flow meter shows the combined GPM for both pools. Required GPM is 154 gpm and the current gpm is at 92 gpm. Please correct to adequate turnover rate.

21 - cyanuric acid level not exceeding maximum

4 ptsCorrected: YesRepeat: No

13-189(c)(2) Cyanuric acid levels shall not exceed 100ppm. Observed cyanuric acid at 175ppm COS: Cyanuric acid corrected to read at

May 22, 2023

Permit/Opening

Score: 942 violations

28 - flow meter: appropriate range and location

5 ptsCorrected: NoRepeat: No

13-190(a) Minimum required turnover rate every 30 mins for spas. CPO stated that the flow meter shows the combined GPM for both pools. Required GPM is 131 gpm and the current gpm is at 92 gpm. Please correct to adequate turnover rate.

30 - deck/rinse shower maintained

1 ptsCorrected: NoRepeat: No

13-201 (b) - Observed deck shower not functional; please repair.