Inspection history

Georgia inspection history is score-based, with violations grouped under each recorded inspection.

Jul 2, 2025

Permit/Opening

Score: 1000 violations
No violations recorded for this inspection.

Jun 24, 2025

Permit/Opening

Score: 746 violations

5 - emergency phone operational and accessible

15 ptsCorrected: NoRepeat: No

13-202(g): An operable, hard-wired, weather proof telephone with direct 911 access shall be readily available.

Observation: The telephone was hard to hear, and dispatchers said they pinged an address of 2310 perimeter park drive. That's not the pool address.

6 - proper disinfectant level

15 ptsCorrected: NoRepeat: No

13-189(c)(1): chlorine shall be maintained at a range of 3-10ppm.

Observation: Chlorine measured at 1.46ppm initially. After adjusting the chlorinator, it decreased to 1.21ppm.

8 - chemical feeder operational and approved

15 ptsCorrected: NoRepeat: No

13-197(a): The water shall be treated with a properly functioning disinfecting equipment.

Observation: Chlorine decreased after turning chlorinator up. CPO notified me that this is a persistent issue and often times uses shock to bring it up to range.

19 - adequate turnover rate

5 ptsCorrected: NoRepeat: No

13-190(a): The equipment shall be operated continuously on a 24 hour basis to maintain minimum required 4 turnovers/day.

Observation: The flow meter reads at 60gpm. The flow meter should read minimum of 100 gpm.

36,000 (gallons)/360 (6 hour turnover in minutes)= 100gpm.

28 - flow meter: appropriate range and location

5 ptsCorrected: NoRepeat: No

13-190(a)(7): An adequately sized flow meter shall be installed.

Observation: Max value is 120 gpm, when it should be 150 gpm.

100gpm x 1.5 = 150gpm.

29 - toilets & lavatories: clean, maintained, and stocked

1 ptsCorrected: NoRepeat: No

13-201(c)(3): Bathrooms should have hot wter temp of 70-104 degrees Fahrenheit.

Observation: Bathrooms did not have any hot water. The water stop flowing when you turn the knob.

Jun 21, 2024

Permit/Opening

Score: 912 violations

19 - adequate turnover rate

5 ptsCorrected: NoRepeat: No

13-190(a)- Equipment shall measure 6 hour turnover rate. Flowmeter was broken. Turnover rate should be at minimum 97; it reads 50. Not corrected from last inspection.

21 - cyanuric acid level not exceeding maximum

4 ptsCorrected: NoRepeat: No

13-189(c)(2) Cyanuric acid levels shall not exceed 100ppm. Cyanuric acid reads 200+ ppm.

Jun 13, 2024

Permit/Opening

Score: 724 violations

6 - proper disinfectant level

15 ptsCorrected: NoRepeat: No

13-189(c)(1) FCL shall be kept between 3-10ppm at all times. Chlorine was reading over 12+ ppm.

19 - adequate turnover rate

5 ptsCorrected: NoRepeat: No

13-190(a)- Equipment shall measure 6 hour turnover rate. Flowmeter was broken. Turnover rate should be at minimum 97; it reads 50.

17 - skimmers/gutters maintained and operable

4 ptsCorrected: NoRepeat: No

13-196(a)(4) Each skimmer shall have a properly designed and operating weir or other departmentally approved means of providing effective skimming. Observed skimmer baskets with debris.

21 - cyanuric acid level not exceeding maximum

4 ptsCorrected: NoRepeat: No

13-189(c)(2) Cyanuric acid levels shall not exceed 100ppm. Cyanuric acid reads 156+ ppm.

Jun 28, 2023

Permit/Opening

Score: 942 violations

19 - adequate turnover rate

5 ptsCorrected: NoRepeat: No

13-190(a)- Equipment shall measure 6 hour turnover rate. Flowmeter was broken.

37 - other violations of the chapter

1 ptsCorrected: NoRepeat: No

13-198(a)- Equipment must be well maintained, there was a hole in the backwash pipe that leaks.