Jun 18, 2025
Permit/Opening
19 - adequate turnover rate
13-190(a): The equipment shall be operated continuously on a twenty-four (24) basis to obtain the minimum required turnover rate. Observed 110GPM and should be reaching 122PM.
3681 N DECATUR RD DECATUR, GA 30032
Inspection scores over time for this facility.
Georgia inspection history is score-based, with violations grouped under each recorded inspection.
Permit/Opening
13-190(a): The equipment shall be operated continuously on a twenty-four (24) basis to obtain the minimum required turnover rate. Observed 110GPM and should be reaching 122PM.
Permit/Opening
13-190(a): The equipment shall be operated continuously on a twenty-four (24) basis to obtain the minimum required turnover rate. Observed 80GPM and should be reaching 120GPM.
13-189(a)(5): All pools shall be kept free of debris. Visible scum shall be removed immediately. Pool surface observed in bad repair.
Permit/Opening
13-189(c)(1): The free chlorine residual in all parts of the pool shall be maintained at a concentration no less than 3ppm and shall not exceed 10ppm. Pool was observed at 13.72ppm.
13-189(c)(1): The pool shall be maintained in an alkaline condition at all times between 7.2-7.8. Pool was observed at 6.9.
13-190(a): The equipment shall be operated continuously on a twenty-four (24) basis to obtain the minimum required turnover rate. Flow meter was not operational.
13-202(c): Each pool operator shall maintain and make available a daily record of operating information and water testing. Records were not observed.
13-184(e)(5): Imminent health hazard exists if sanitary facilities are not maintained in a clean and sanitary condition. Both bathrooms were observed to be unsanitary and unclean.
13-201(c)(4)
13-187(c): The current inspection report shall be displayed in the pool area. Inspection report was not observed.
13-189(a)(5): All pools shall be kept free of debris. Visible scum shall be removed immediately. Pool surface observed in bad repair.
13-202(i): Each pool facility shall have in place an approved EAP. No EAP was observed.
13-187(c): The operating permit shall be framed and displayed in a conspicuous place. Operating permit was not observed.
Routine
13-190(a) A minimum turnover of 122gpm should be maintained, observed turnover was 90gpm.
13-189(a)(5) All pools shall be kept free from sediment, dirt or debris by frequent brushing and vacuuming of the bottom and sidewalls. Visible scum shall be removed immediately. Pool surface appeared stained at inspection.
Permit/Opening
13-201(k) At all times an adequate supply of liquid soap, toilet paper and paper towels shall be provided and stored in appropriate dispensers conveniently accessible to users. Bathrooms were not adequately stocked at time of inspection.
13-189(a)(5) All pools shall be kept free from sediment, dirt or debris by frequent brushing and vacuuming of the bottom and sidewalls. Visible scum shall be removed immediately. Pool surface appeared stained at inspection.
Permit/Opening
13-189(c)(6)Water in pool was cloudy at time of inspection. Water should be of such clarity that the main drain at deepest end is visible.
13-189(c)(1)The free chlorine residual must, at all times, be between 3-10ppm. Free chlorine reading was 1.68 at time of inspection
13-189(c)(1)An alkaline condition of pH 7.2-7.8 shall be maintained at all times. pH reading was 7.1 at time of inspection.
13-197(a) The water shall be continuously chemically treated with approved equipment. Chlorinator out of operation at time of inspection.
13-190(a)13-205(b)(1) The equipment shall be operated continuously to obtain one turnover every six hours.
13-109(a)(7) An adequately sized flow meter shall be installed on return line to indicate circulation rate. Flow meter not working at time of inspection.
13-196(a)(4)Each skimmer shall have properly designed and operating weirs. No weirs observed in skimmers at time of inspection.