Mar 3, 2026
Routine
2914 EVANS WOOD DR DORAVILLE, GA 30340
Inspection scores over time for this facility.
Georgia inspection history is score-based, with violations grouped under each recorded inspection.
Routine
Routine
Regulation: 511-6-1.04(6)(f) - time/temperature control for safety; cold holding (p)
Observed milk in milk cooler cold holding above 41F. See temperature logs for specifics. CA: Except during preparation, cooking, or cooling, or when time is used as the public health control, time/temperature control for safety food shall be maintained at 41°F (5°C) or below COS: Discussed with PIC that milk cooler needs to be adjusted so that it may hold milk at 41F or lower even while being held open. Ice was added to the milk in the milk cooler. Milk that was properly held at 41F or lower from walk in cooler was added to the milk cooler are replacements.
Routine
Regulation: 511-6-1.04(4)(q) - food storage (c)
At the time of inspection, observed food stored on floor by delivery person. Informed PIC, the delivery was implemented at time of the food serving. Staff was short two people.
Routine
Regulation: 511-6-1.04(6)(f) - time/temperature control for safety; cold holding (p)
Observed reach in cooler holding at 55.5 degrees. Informed PIC request repair and store food in the walk in cooler until RIC is repaired.
Regulation: 511-6-1.03(2)(a)-(n)(p),(q) - responsibility of pic (pf)
Observed custodian enter kitchen area through back door and proceed to remove water from walk in cooler while PIC was assisting with serving food on the food service line. PIC informed custodian that unauthorized personnel were not allow to assess kitchen area.
Regulation: 511-6-1.07(5)(a),(b) - good repair, physical facilities maintained; cleaning, frequency & restrictions, cleaned often enough to keep them clean (c)
Observed condensation line behind warming cabinet leaking water onto floor, observed drain floor cover detached from drain. Observed surface of vents with dust. Informed PIC to submit request to Service Center for repair.
Routine
Regulation: 511-6-1.06(5)(r),(s) - frequency, removal of refuse, recyclables and returnables often enough to minimize odors and attracting pests; receptacles or vehicles, removal from premises in approved manner (c)
Observed dumpster rusted out on bottom. Observed trash under dumpster. Informed PIC to remove all trash from dumpster area immediately.
Routine
Regulation: 511-6-1.07(2)(k) - insect control devices (c)
Observed live fruit flies and pest in kitchen. A active baby brown-banded cockroach located on surface of handwashing sink (near back door). Informed PIC of the findings and was told that a work order was submitted. Observed request details submitted by Ms. Lattimore (Manager)