May 28, 2026
Permit/Opening
3450 EVANS RD ATLANTA, GA 30341
Inspection scores over time for this facility.
Georgia inspection history is score-based, with violations grouped under each recorded inspection.
Permit/Opening
Permit/Opening
13-190(a): Observed turnover rate more than 6 hours. Observed flow meter at 50gpm. CA: The equipment shall be operated continuously on a twenty-four (24) hour basis to obtain the minimum required number of four (4) turnovers per day, or one turnover every six (6) hours (pools); every 30 mins. for spas. Discussed with manager that the lowest gpm should be 126gpm.
Permit/Opening
Regulation: 511-3-5-.17(4) - (4) stabilizer (if used) cyanuric acid,ppm ideal: 30-50 maximum: 90 comments: if stabilizer is: too high: - may reduce chlorine efficacy too low: - chlorine residual rapidly destroyed by sunlight note: stabilizer is not needed in indoor or br
Observed Cyanuric acid levels at 260+
Permit/Opening
Regulation: 511-3-5-.06(1)(l) - (l) open joints or gaps larger than three-sixteenths inch wide or with vertical elevations exceeding 1/4 inches shall be rectified using appropriate fillers. construction joints where pool coping meets the decks shall be watertight and shall not allo
511-3-5-.06(1)(l) - (l) Open joints or gaps larger than three-sixteenths inch wide or with vertical elevations exceeding 1/4 inches shall be rectified using appropriate fillers. Construction joints where pool coping meets the decks shall be watertight and shall not allow water enter. Fill-in opening underneath coping.