Dunwoody, DeKalb County

CHATEAU AT DUNWOODY CONDOMINIUMS

4430 TILLY MILL RD DORAVILLE, GA 30360

Pool
Latest score
91
May 6, 2026
City
Dunwoody
County
DeKalb
Inspections
9

Score history

Inspection scores over time for this facility.

Inspection history

Georgia inspection history is score-based, with violations grouped under each recorded inspection.

May 6, 2026

Permit/Opening

Score: 912 violations

19 - adequate turnover rate

5 ptsCorrected: NoRepeat: No

13-190(a)The equipment shall be operated continuously on a twenty-four (24) hour basis to obtain the minimum required number of four (4) turnovers per day, or one turnover every six (6) hours (pools);

Observed flowrate at 70 GPM. 33,000gal/360Min=91.6 GPM

15 - depth and no diving markers, step marking; installed and contrasting

4 ptsCorrected: NoRepeat: No

Observed missing depth tiles along the pool water line (vertical wall). 13-188(d)(1)Permanent, slip-resistant, easily-readable depth markers at least 4 inches (4”) high; black letters and numbers on a white background indicated in feet and inches when applicable (metric allowed only if accompanied by feet and inches); Markers on vertical pool wall at or above waterline and on the deck within 18 inches (18”) of the pool wall positioned to read while standing on the deck facing the pool water; Located at minimum and maximum water depths and all points of slope change; Installed at intermediate increments of water depths not to exceed two feet (2’) and shall not be spaced to exceed 25 feet (25’);

Jun 27, 2025

Re-inspection

Score: 991 violation

29 - toilets & lavatories: clean, maintained, and stocked

1 ptsCorrected: NoRepeat: No

13-201(k) A minimum of 1 diaper changing station for babies shall be provided in each men's and women's section of the bathhouse.

Jun 23, 2025

Re-inspection

Score: 795 violations

9 - filter: approved, maintained and operating

15 ptsCorrected: NoRepeat: No

13-190(a) All circulation system components, including filters, pumps, hair lint strainer and other similar components shall function properly and be maintained in clean conditions.

10 - pump: approved, maintained and operating

15 ptsCorrected: NoRepeat: No

13-190(a) All circulation system components, including filters, pumps, hair lint strainer and other similar components shall function properly and be maintained in clean conditions.

17 - skimmers/gutters maintained and operable

4 ptsCorrected: NoRepeat: No

13-190(a) All circulation system components, including filters, pumps, hair lint strainer and other similar components shall function properly and be maintained in clean conditions.

29 - toilets & lavatories: clean, maintained, and stocked

1 ptsCorrected: NoRepeat: No

13-201(k) A minimum of 1 diaper changing station for babies shall be provided in each men's and women's section of the bathhouse.

37 - other violations of the chapter

1 ptsCorrected: NoRepeat: No

13-196(a) The actual water level shall be maintained within the operation water level range of the systems' skimmer weir device or gutter rim.

Jun 16, 2025

Routine

Score: 852 violations

2 - self-closing / self-latching gates

15 ptsCorrected: NoRepeat: No

13-202(a)(2) Entry into the pool area shall be at the shallow end of the pool through self- closing, self-[latching gate or door that has a positive mechanism mounted.

7 - ph between 7.2 and 7.8

15 ptsCorrected: NoRepeat: No

13-189(c)(1) The pool shall be maintained in an alkaline condition at all times with a pH level between 7.2-7.8

May 9, 2025

Permit/Opening

Score: 934 violations

19 - adequate turnover rate

5 ptsCorrected: NoRepeat: No

13-190(a);13-205(b)(1) Observed flowrate at 90 GPM. Flowrate for 50,000 gallon pool is 139 GPM. Flowrate is below 139GPM.

29 - toilets & lavatories: clean, maintained, and stocked

1 ptsCorrected: NoRepeat: No

13-201(k) Observed no soap or paper towels at both bathrooms. NOTE: One bathroom missing gender signage

37 - other violations of the chapter

1 ptsCorrected: NoRepeat: No

13-200(a) Observed one light bulb in deep end of pool not functioning.

37 - other violations of the chapter

1 ptsCorrected: NoRepeat: No

13-196(a) The water level shall be maintained within operation of skimmers. Observed water level at the skimmer line for one of three skimmers. CPO is adding water.

Aug 30, 2023

Routine

Score: 951 violation

19 - adequate turnover rate

5 ptsCorrected: NoRepeat: No

13-205(b)(1): Code says there must be 1 turnover every 6 hours -Flow needed: 91gpm -Flow observed: 70gpm

Jun 22, 2023

Re-inspection

Score: 924 violations

17 - skimmers/gutters maintained and operable

4 ptsCorrected: NoRepeat: No

13-196(a)(4): Each skimmer shall have a properly designed and operating weir or other departmentally approved means of providing effective skimming. Observation: None of the skimmers had weirs.

22 - signs: peak occupancy/pool/spa/signs legible and in clearview

2 ptsCorrected: NoRepeat: No

13-202(m): safety rules must contain at a minimum the 12 statements in the pool code. Observation: signs are missing no food or drinks allowed.

34 - inspection report placed in public view

1 ptsCorrected: NoRepeat: No

13-187(c): Current inspection report shall be displayed in conspicuous place easily readable by the public. Observation: Their last inspection report displayed is 06/07/2022. This is 2 inspections behind.

37 - other violations of the chapter

1 ptsCorrected: NoRepeat: No

13-189(a)(5): All pools must be kept free of dirt, sediment, or debris. Observation: Heavy staining throughout pool surface.

13-202(i): EAP should include: chemical emergency action plan, emergency crisis plan, water rescue & injury emergency plan, drill procedures for emergency situations. Observation: missing these sections.

Jun 8, 2023

Permit/Opening

Score: 754 violations

10 - pump: approved, maintained and operating

15 ptsCorrected: NoRepeat: No

13-190(a)(1): Pumps shall be adequate to provide required turnover rate. Observation: Pump is not providing enough circulation. Gauges on filter were initially 0, after back washing it went to 5 and 10. Flow meter was initially 0, and rose to 20. Skimmers are producing weak suction. These are all indicators of a malfunctioning pump.

28 - flow meter: appropriate range and location

5 ptsCorrected: NoRepeat: No

Flow meter observed to be at 20 after back washing.

17 - skimmers/gutters maintained and operable

4 ptsCorrected: YesRepeat: No

corrected on sight by cleaning skimmers.

37 - other violations of the chapter

1 ptsCorrected: YesRepeat: No

13-189(a)(5): All pools must be kept free of dirt, sediment, or debris. Observation: Heavy staining throughout pool surface.

13-198(b): ventilation of fresh made up air must be provided for all equipment rooms. Observation: No ventilation installed.

Jun 5, 2023

Permit/Opening

Score: 754 violations

4 - water clarity: main drains clearly visible

15 ptsCorrected: NoRepeat: No

13-189(c)(6): Code says water should be clear enough to see the drains at the bottom -Observed cloudy water

19 - adequate turnover rate

5 ptsCorrected: NoRepeat: No

13-190(a): Code says there should be one turnover every 6 hours -Turnover rate needed: 91 -Turnover rate observed: 75

17 - skimmers/gutters maintained and operable

4 ptsCorrected: NoRepeat: No

13-196(a)(4): Code says skimmers must have an operable weir on them -Observed no operable weirs

37 - other violations of the chapter

1 ptsCorrected: NoRepeat: No

13-188(a): Code says pool surface must be in good repair -observed pool surface to be damaged and in bad repair