Apr 9, 2026

Permit/Opening

Score: 916 violations

15 - depth and no diving markers, step marking; installed and contrasting

4 ptsCorrected: NoRepeat: No

13-188(d)(2): Depths of pool less than 5 feet shall have permanent "NO DIVING" in minimum 2 inch black letters with a white background spaced evenly around pool perimeter. Observed "NO DIVING" markers smaller than 2 inches.

22 - signs: peak occupancy/pool/spa/signs legible and in clearview

2 ptsCorrected: NoRepeat: No

13-202(m): Safety rules and regulations must contain at a minimum the 12 required statements in the pool code. Observed signage missing several required statements. Provided CPO with list of required statements.

30 - deck/rinse shower maintained

1 ptsCorrected: NoRepeat: No

13-201(b): A shower with tempered water 70F to 104F shall be provided at each entrance to pool area. Observed no deck shower.

34 - inspection report placed in public view

1 ptsCorrected: NoRepeat: No

13-187(c): Current inspection report shall be displayed where it is easily readable. Observed no inspection report posted.

37 - other violations of the chapter

1 ptsCorrected: NoRepeat: No

13-189(c)(1): Approved test kits shall be provided and used. Observed no test kit for residents to used between company visits(2x/week).

37 - other violations of the chapter

1 ptsCorrected: NoRepeat: No

13-187(c): The operating permit shall be displayed where it is easily readable at all times. Observed no permit displayed.

Aug 13, 2025

Routine

Score: 991 violation

37 - other violations of the chapter

1 ptsCorrected: NoRepeat: No

13-189(a)(5) All pools shall be kept free from sediment, dirt, or debris by frequent brushing and vacuuming. The pool had sediment and leaves at the bottom of the pool.

May 22, 2025

Permit/Opening

Score: 991 violation

29 - toilets & lavatories: clean, maintained, and stocked

1 ptsCorrected: NoRepeat: No

13-201(k) No diaper changing tables in either restroom. Diaper changing tables must be provided for sanitary reasons.

Apr 2, 2024

Permit/Opening

Score: 1000 violations
No violations recorded for this inspection.

Sep 5, 2023

Routine

Score: 952 violations

15 - depth and no diving markers, step marking; installed and contrasting

4 ptsCorrected: NoRepeat: Yes

13-188(d)(2): Code says "No Diving" should be permanent in 2 inch minimum lettering and tiled -Observed universal "No Diving" logo which cannot be used by itself

34 - inspection report placed in public view

1 ptsCorrected: NoRepeat: No

13-187(c): Code says current inspection must be in public view -Observed old inspection

Jul 18, 2023

Routine

Score: 912 violations

36 - daily recordkeeping: water testing and self inspection performed

5 ptsCorrected: NoRepeat: Yes

13-202(c): Code says pool must have a daily record keeping -Observed no log book

15 - depth and no diving markers, step marking; installed and contrasting

4 ptsCorrected: NoRepeat: No

13-188(d)(2): Code says "No Diving" should be permanent in 4 inch minimum lettering and tiled -Observed universal "No Diving" logo which cannot be used by itself

Jun 8, 2023

Re-inspection

Score: 942 violations

36 - daily recordkeeping: water testing and self inspection performed

5 ptsCorrected: NoRepeat: No

Did not observed daily log book. Advised to keep a daily log book and check chemicals at least 2x a day with any corrective actions

31 - dressing showers: clean, maintained, hot and cold water available

1 ptsCorrected: NoRepeat: No

No hot water in restrooms. There is no water heater

Jun 2, 2023

Routine

Score: 922 violations

15 - depth and no diving markers, step marking; installed and contrasting

4 ptsCorrected: NoRepeat: No

13-188(d)(2): Code says "No Diving" should be permanent in 2 inch minimum lettering and tiled -Observed universal "No Diving" logo which cannot be used by itself

21 - cyanuric acid level not exceeding maximum

4 ptsCorrected: NoRepeat: No

13-189(c)(2): Code says cyanuric acid levels shall not exceed 100 ppm -First Observation: 101 ppm -Second Observation: 104 ppm