Routine
13-201(c)(3) Laboratory with tempered water with a temperature range of 70F to 104 shall be provided for each 100 men or women. There wasn't hot water coming out of the faucet in the male and female bathroom.
13-184(e)(5) Imminent health hazard exist if the sanitary facilities are not functional or if the facilities are not maintained in a clean and sanitary conditions. One toilet in the female bathroom isn't working.
13-189(a)(5) All pools shall be kept free from sediment, dirt or debris. Observed sediment on the bottom of the pool.
Routine
13-202(h) The telephone number of the pool operator, manager and of the health department shall be posted at the telephone area.
13-189(a)(5) All pools shall be kept free from sediment, dirt or debris by frequent brushing and vacuuming of the bottom and sidewalls. Visible scum shall be removed immediately.
Permit/Opening
Routine
Regulation: 511-3-5-.23(3)(d) - (d) the operator shall receive a copy of the inspection and place it in a location protected from the weather and in public view as designated by the health authority.
Inspection report was not observed to be in public view.
Permit/Opening
13-202(m) observed pool rules sign not meeting the minimum code requirements. Can be found on page 42 of the DeKalb County Pool Ordinance.
Routine
13-190(a)(7): Code says flow meter must be operable -Observed flow meter to be leaking and broken
13-187(c): Code says inspection must be in public view -Observed inspection not in public view
Re-inspection
13-189(c)(1): Code says that chlorine must be between 3.0-10.0 -First Reading: 0.22 -Second Reading: 6.33
13-187(c): Code says current inspection should be in public view -Observed no inspection
Routine
13-189(c)(1): Code says that chlorine must be between 3.0-10.0 -First Reading: 12.58 -Second Reading: 10.63
13-189(c)(1): Code says pH must be 7.2-7.8 -First Reading: 7.1 -Second Reading: 7.2 -COS
13-187(c): Code says current inspection should be in public view -Observed no inspection
Routine
13-201(j): Code says trash cans must have lids -Observed no lids in women's room