STONE MOUNTAIN, DeKalb County

HAIRSTON WOODS APARTMENTS

1173 N HAIRSTON RD STONE MOUNTAIN, GA 30083

Pool
Latest score
94
Jun 2, 2026
City
STONE MOUNTAIN
County
DeKalb
Inspections
5

Score history

Inspection scores over time for this facility.

Inspection history

Georgia inspection history is score-based, with violations grouped under each recorded inspection.

Jun 2, 2026

Permit/Opening

Score: 942 violations

19 - adequate turnover rate

5 ptsCorrected: NoRepeat: No

13-190(a) The equipment shall be operated continuously on a 24 hour basis to obtain the minimum required number of four turnovers per day or one turnover every six hours. Observed flow meter reading was not efficient enough to meet these standards.

37 - other violations of the chapter

1 ptsCorrected: NoRepeat: No

13-201(k): At all times a minimum of 1 diaper changing station for babies shall be provided in each men’s and women’s section of the bathhouse. Observed no baby changing station in bathhouse.

Jul 16, 2024

Re-inspection

Score: 951 violation

19 - adequate turnover rate

5 ptsCorrected: NoRepeat: No

13-190(a) The equipment shall be operated continuously on a twenty four hour basis to obtain the minimum required number of four tunrovers per day, or one turnover every six hours. Recorded flow meter value was not meeting these standards.

Jun 24, 2024

Routine

Score: 763 violations

6 - proper disinfectant level

15 ptsCorrected: NoRepeat: No

13-189(c)(1) The free chlorine residual in all parts of the pool shall be maintained at a concentration of a minimum of three and a maximum of ten. Chlorine was measured at .50.

19 - adequate turnover rate

5 ptsCorrected: NoRepeat: No

13-190(a) The equipment shall be operated continuously on a 24 hour basis to obtain the minimum required number of four turnovers per day or one turnover every six hours. Observed flow meter reading was not efficient enough to meet these standards.

21 - cyanuric acid level not exceeding maximum

4 ptsCorrected: NoRepeat: No

13(189)(C)(2) Cyanuric acid levels shall not exceed 100 ppm. Cyanuric acid level was recorded at 101.

May 23, 2024

Permit/Opening

Score: 951 violation

19 - adequate turnover rate

Regulation: 511-3-5-.07(1)(a) - (a) the equipment for a swimming pool shall be of adequate size to turn over the entire pool water capacity. the turnover rate for pools constructed after the adoption of this chapter shall not exceed the sum of one and one-half times the average wat

5 ptsCorrected: NoRepeat: No

13-190(a) The equipment shall be operated continuously on a 24 hour basis to obtain the minimum required number of four turnovers per day or one turnover every six hours. Observed flow meter was lower than required turnover rate.

Jul 12, 2023

Permit/Opening

Score: 951 violation

28 - flow meter: appropriate range and location

5 ptsCorrected: NoRepeat: No

13-190(a): Adequately sized flow meter shall be installed to accurately indicate circulation rate in GPM. Obs: Flow meter max value is 120 gpm. Flow meter should be 1.5x of turnover rate (102gpm). Max value should be 155gpm.