Permit/Opening
Re-inspection
13-202(a)(2): pool entrances should be through a self-closing, self-latching gate; corrected onsite; office door to pool (which is not self-latching) is not closed and locked
13-189(c)(1): pH level shall be maintained between 7.2 and 7.8; observed initial reading at 7.0; corrected onsite and brought up to 7.2
13-205(b)(1): a turnover rate shall exist of one turnover every six (6) hours for an outdoor pool; note the flow meter reading of 100gpm
13-202(m): safety regulations shall be posted and easily readable in a conspicuous place; observed that bather load was not posted
13-201(k): a minimum of one diaper changing station shall exist in each bathroom; observed that no diaper changing stations exist in restroom
13-201(b): a shower with tempered water shall exist at each entrance; observed that pool facility did not have a deck shower
Routine
13-202(a)(2): entrance to pool must be self-closing and self-latching; observed that at time of inspection, only entrance to the pool was through an office door that was not self-latching
13-189(c)(1): for an outdoor pool, a free-chlorine residual shall be maintained at a concentration of no less than 3ppm; observed the chlorine reading to be 0.18ppm at time of inspection
13-205(b)(1): a turnover rate shall exist of one turnover every six (6) hours for an outdoor pool; note the flow meter reading of 100gpm
13-189(c)(2): cyanuric acid levels shall not exceed 100ppm; observed acid levels at 177ppm
13-202(m0: safety rules and regulations shall be conspicuously posted; observed that the bather load was not posted
13-201(k): a minimum of one diaper changing station shall exist in each bathroom; observed that no diaper changing stations exists in restroom
13-201(b): a shower with tempered water shall exist at each entrance; observed that pool facility did not have a deck shower
13-198(a0: the equipment room shall be kept safe and clean; observed that at time of inspection equipment room was unlocked
Permit/Opening
Permit/Opening
13-189(c)(6): At all times when the pool ins in use, the water shall be of such clarity that the main drains on the bottom of the pool at the deepest point are clearly visible from the deck. Observed the pool water to be cloudy and the main drain was not clearly visible. Observed the pool to be cloudy. Inspector could not see the main drains from the deck.
13-189(c)(1): The free chlorine residual in all parts of the pool shall be maintained at a concentration of no less than 3ppm at all times. Observed free chlorine at 2.58ppm.
3-189(c)(2):Cyanuric acid levels shall not exceed 100 ppm. Observed the cyanuric acid level at 200+PPM. Observed daily logs of CYA at 200+PPM.
Routine
13-189(c)(2):Cyanuric acid levels shall not exceed 100 ppm. Observed the cyanuric acid level at 214+. Advised to keep a log of daily cyanuric acid levels and drain the pool once levels get to 80ppm.
13-201(k): A minimum of 1 diaper changing station for babies shall be provided in each men's and women's section of the bathhouse. Observed no diaper changing station in either bathroom. Advised to get a diaper station in bathrooms.
13-187(c):The current inspection report shall be displayed in a conspicuous place. Observed the current report was not posted on the wall. Advised to keep the most current report posted.
Routine
13-201(k)A minimum of 1 diaper changing station for babies shall be provided in each men's and women's section of the bathhouse. I observed no changing station in men's or women's bathhouse.
Routine
13-189(c)(1): The free chlorine residual in all parts of the pool shall be maintained at a concentration of no less than 3ppm at all times. Was at 0 due to chlorinator not having any chlorine tablets.
13-197(a)The water in each pool shall be continuously chemically treated with an approved disinfecting agent feeder didn't have any chlorine tablets.
13-189(c)(2) Cyanuric acid levels shall not exceed 100ppm but was at 129ppm
13-197(i)No disinfectant added by hand as the sole or primary method of adding disinfectant or ph control chemical. Observed their were chlorine tablets in the skimmers.
Permit/Opening
Permit/Opening
13-189(c)(1): The free chlorine residual in all parts of the pool shall be maintained at a concentration of no less than 3ppm at all times. Observed FLC to be more than 3ppm, FCL was 16.52ppm+
Permit/Opening
13-202(a)(1): Each Public pool must be at least 5' in height as measured from the exterior grade. No climbable objects shall be allowed within 3' from the barrier measured horizontally from the exterior grade. Observed the pool gate to not self-latch
13-189(c)(1): The free chlorine residual in all parts of the pool shall be maintained at a concentration of no less than 3ppm at all times. Observed FLC to be more than 3ppm, FCL was 19.00ppm+
Observed handrails to not be firmly tighten.
Routine
13-190(a)(7): An adequately sized flow meter must be installed on return line. Obs: Max value on red flow meter is 120gpm. According to turnover rate of 111gpm, the flow meter max value should be 167gpm. Max value must be 1.5x of turnover rate.
13-190(a): All circulation systems must function properly. Obs: Flow meter is inoperable.
13-188(d)(2): At shallow portions of the pool where depths are 5 ft or less shall have permanent "No Diving" in minimum 2 inch black letters with white background on permanent tile. Obs: NO DIVING is less than 2 inches tall.
13-196(a)(4): Each skimmer shall have properly designed and operating weir or other departmentally approved means of effective skimming. Obs: None of weirs are in skimmers. Also, skimmer baskets are full of debris.
13-202(m): safety rules need to contain minimum 12 statements. Obs: Rules is missing "No spitting/spouting" and info for bather load & hours of operation.
13-189(a)(5): All pools shall be kept free of sediment, dirt, debris. Obs: There is stains throughout. It's more visible on steps.
Routine
13-190(a): Equipment shall be operated continuously on a 24 hour basis to obtain the minimum required number of 1 turnover every 6 hours. Obs: Flow meter is inoperable.
13-196(a)(4): each skimmer shall have properly designed and operating weir. Obs: CPO corrected by adding weirs.
13-202(m): safety rules and regulations should have the minimum 12 statements. Obs: signs are missing "bathers with open wounds" and "no spitting/spouting". Bather load and hours of operation not filled in.
13-198(b): enclosure must be ventilated with outside air by a chlorine resistant exhaust fan with vents that are located at the top of the enclosure. Obs: No exhaust fan.