29 - toilets & lavatories: clean, maintained, and stocked
Observed men's restroom without the baby changing station. CA: Both men's and women's restrooms/ all restrooms must have baby changing stations.
2274 WINDING WOODS DR TUCKER, GA 30084
Inspection scores over time for this facility.
Georgia inspection history is score-based, with violations grouped under each recorded inspection.
Permit/Opening
Observed men's restroom without the baby changing station. CA: Both men's and women's restrooms/ all restrooms must have baby changing stations.
Routine
-Historically has not had a site glass
Permit/Opening
Observed flow meter reading at 150gpm, making the pool have a turnover rate of 16.7 hours every 24 hours. CA: The equipment shall be operated continuously on a 24 hr basis to obtain the minimum required number of 4 turnovers per day. Discussed with CPO that he will get a different flow meter because he believes that the current flow meter is in disrepair.
Observed men's restroom without the baby changing station. CA: Both men's and women's restrooms/ all restrooms must have baby changing stations.
Routine
13-190(a): The equipment shall be operated continuously on a 24-hour basis to obtain a minimum of 4 turnovers per day. Observed turnover rate at 240, should be at least 417.
Re-inspection
13-190(a): The equipment shall be operated continuously on a 24-hour basis to obtain a minimum of 4 turnovers per day. Observed turnover rate at 225, should be at least 417.
13-198(a): All equipment shall be located in a permanent room or completely enclosed area. Observed equipment located outside of the equipment room and accessible to bathers.
Routine
13-202(g): An operable, hard-wired, weatherproof telephone with direct 911 access or capability installed in a conspicuous location shall be readily available at all times. Observed emergency phone not working.
13-189(c)(1): The free chlorine residual in all parts of the pool shall be maintained at a concentration of no less than 3ppm and no more than 10 ppm. Observed free chlorine at 0.01 ppm and again at 0.08 ppm.
13-197(a): The water in each pool shall be chemically treated with an approved disinfecting agent. Observed CPO fix chlorinator.
13-190(a): The equipment shall be operated continuously on a 24-hour basis to obtain a minimum of 4 turnovers per day. Observed turnover rate at 225, should be at least 417.
13-184(e)(5): Imminent Health Hazard exists if the sanitary facilities are not functional or maintained in a clean and sanitary condition. Observed unflushed toilets and wet floors in bathrooms.
13-198(a): All equipment shall be located in a permanent room or completely enclosed area. Observed equipment located outside of the equipment room and accessible to bathers.
Permit/Opening
13-201(b) Observed restroom shower without hot water; a shower with tempered water range of 70 degrees and 104 shall be provided.
Violation #37 Observed pool night light damaged. Informed CPO to replace damaged light lens cover. COS
Routine
13-202(G) - AN OPERABLE, HARD-WIRED, WEATHERPROOF TELEPHONE WITH DIRECT 911 ACCESS SHALL BE READILY AVAILABLE AT ALL TIMES. AT THE TIME OF INSPECTION THE PHONE HAD NO DIAL TONE. CORRECTED ON SITE
13-189(C)(1) - FREE CHLORINE SHALL BE MAINTAINED BETWEEN 3PPM AND 10 PPM AT ALL TIMES. AT INSPECTION OBSERVED THE CHLORINE AT 2.39, 2.54, 2.97 AND 3.66.
13-202(D) - LIFESAVING EQUIPMENT SHALL BE READILY AVAILABLE AND IN GOOD CONDITION. AT INSPECTION FOUND THAT THE SHEPHERD'S HOOK WAS NOT CONNECTED TO A NON-TELESCOPING POLE. A ROPE WAS NOT ATTACHED TO THE LIFESAVING RING. CPO WAS ABLE TO SCREW THE HOOK INTO A POLE AND ATTACH THE ROPE TO THE BUOY
13-190(a) - EQUIPMENT SHALL OBTAIN MINIMUM REQUIRED ONE TURNOVER EVERY 6 HOURS. OBSERVED FLOWMETER READING OF 180 GPM. MINIMUM FOR THIS POOL IS ~416 GPM
13-184(e)(5) - IMMINENT HEALTH HAZARD IF SANITARY FACILITIES ARE NOT FUNCTIONAL. ONE FAUCET IN MEN'S BATHROOM SINK IS NOT OPERABLE
13-187(C) - OPERATING PERMIT SHALL BE FRAMED, DISPLAYED AND EASILY READABLE BY THE PUBLIC