May 20, 2026
Permit/Opening
1535 BROCKETT RD TUCKER, GA 30084
Inspection scores over time for this facility.
Georgia inspection history is score-based, with violations grouped under each recorded inspection.
Permit/Opening
Permit/Opening
Hot water was not available.
Permit/Opening
13-188(d)(1) - Permanent, slip-resistant, easily-readable depth markers at least 4 inches (4”) high. Observed "FT" was not at least 4 inches high.
13-201(K) - a minimum of 1 diaper changing station for babies shall be provided in each men and women's bathrooms
13-201(c)(3)- 1 lavatory, with tempered water with a temperature range of 70F to 104F shall be provided for each 100 men or women. Observed men and women restrooms lacking tempered water between the range of 70F to 104F.
Routine
13-188(d)(1) - Permanent, slip-resistant, easily-readable depth markers at least 4 inches (4”) high. Observed "FT" was not at least 4 inches high
13-202(m) - Rules must contain at a minimum the 12 statements in the pool code on pg 42 for a pool; sign was missing some statements
13-201(K) - a minimum of 1 diaper changing station for babies shall be provided in each men and women's bathrooms
13-187(C) operating permit shall be framed and displayed. Observed expired permit
13-202(i) a written copy of the emergency action plan shall be located to allow for immediate access in case of an emergency. Observed missing EAP
13-188(h)(9) - 1 covered and lined trash receptacle shall be provided in the pool area. Observed trash full and not lined
Routine
13-189(C)(1) - The free-chlorine residual in all parts of the pool shall be maintained between 3ppm and 10 ppm. Observed chlorine at 2.87 ppm. Corrected to 4.59 ppm
13-189(c)(4) - The pool water shall be tested for the disinfectant level and pH at least 2 times each day
13-188(d)(1) - Permanent, slip-resistant, easily-readable depth markers at least 4 inches (4”) high. Observed "FT" was not at least 4 inches high
13-202(m) - Rules must contain at a minimum the 12 statements in the pool code on pg 42 for a pool; sign was missing some statements
13-201(c)(3) - 1 lavatory, with tempered water with a temperature range of 70°F to 104°F shall be provided for each 100 men or women.
13-201(k) - A minimum of 1 diaper changing station for babies shall be provided in each men’s and women’s section of the bathhouse
13-187(c) - The operating permit shall be framed and displayed in conspicuous place as close to the pool entrance as possible such that it is easily readable by the public at all times.
Permit/Opening
Permit/Opening
13-202(g)- An operable, hardwired, weatherproof, telephone with direct 911 access or capability installed in a conspicuous location shall be readily available at all times.
Phone was not operable
13-189(c)(1)- the free chlorine residual in all parts of the pool shall be maintained at a concentration of no less than one and one half(1.5) parts per million Chlorine observed at 0.65PPM
13-190(b)(1) The equipment must be operated continuously too maintain a minimum of one turn over every 6 hours. It was observed that the flow meter was at 70 GPM , it needs to be at 83 GPM or higher for a 30,000 gallon pool