Jun 3, 2026
Permit/Opening
2060 CRESCENT CENTER BLVD TUCKER, GA 30084
Inspection scores over time for this facility.
Georgia inspection history is score-based, with violations grouped under each recorded inspection.
Permit/Opening
Permit/Opening
13-188(d)(1): Observed pool depth markers on the outside edge of the pool smalled than 4 inches.
CA: Permanent, slip-resistant, easily-readable depth markers at least 4 inches (4”) high; black letters and numbers on a white background indicated in feet and inches when applicable (metric allowed only if accompanied by feet and inches);
CPO stated that he will purchase the 4 inch "F" and "T" markers.
Permit/Opening
511-3-5-.22(9) - (9) Water Testing Frequency. The trained operator or responsible person shall collect water samples from the water in the pool for monitoring. An in-line sampling port may be used for water held in reservoirs. The water quality testing frequency shall be twice daily by designated person or CPO. Manager was advised to keep a water quality data log sheet on site and ready for inspector.
13-184(e)(5) Unsecured handrails considered an imminent health hazard-safety hazard. Informed CPO to repair and properly secure to provide reoccurrence. COS by Wilson Pools.
Regulation: 511-3-5-.08(6) - (6) all piping shall be marked with directional arrows as necessary to determine flow direction. all piping in the equipment room shall be permanently identified by its use and the pool and or aquatic feature it serves.
511-3-5-.08(6) - (6) All piping shall be marked with directional arrows as necessary to determine flow direction. All piping in the equipment room shall be permanently identified by its use and the pool and or aquatic feature it serves.COS
Re-inspection
Regulation: 511-3-5-.22(9) - (9) water testing frequency. the trained operator or responsible person shall collect water samples from the water in the pool for monitoring. an in-line sampling port may be used for water held in reservoirs. the water quality testing frequency shal
511-3-5-.22(9) - (9) Water Testing Frequency. The trained operator or responsible person shall collect water samples from the water in the pool for monitoring. An in-line sampling port may be used for water held in reservoirs. The water quality testing frequency shall be twice daily by designated person or CPO.
Regulation: 511-3-5-.23(3)(d) - (d) the operator shall receive a copy of the inspection and place it in a location protected from the weather and in public view as designated by the health authority.
511-3-5-.23(3)(d) - (d) The operator shall receive a copy of the inspection and place it in a location protected from the weather and in public view as designated by the health authority. At the time of re-inspection the permit , inspection report or CPO was not posted as required.
#37 Violation : Permit not displayed.
Complaint
Regulation: 511-3-5-.07(1)(e ) - (e) water clarity shall be maintained. when standing at the pool's edge at the deep end, the main drain suction outlet covers or a four inch by four inch square marker tile in contrasting color shall be clearly visible. when standing at a spa's e
511-3-5-.07(1)(e ) Water clarity shall be maintained. When standing at the pool's edge at the deep end, the main drain suction outlet covers or a four inch by four inch square marker tile in contrasting color shall be clearly visible.
Regulation: 511-3-5-.17(2) - (2) chemical values: ph
511-3-5-.17(2) Chemical Values: pH (2) Chemical Values: pH 7.2 7.4-7.6 7.8 Alkalinity (buffering). At the time of inspection the pH level was 6.7. Informed manager to convey to the CPO to increase pH level. At the time of inspection pool is closed.
Regulation: 511-3-5-.18(10)(b) - (b) a minimum one-fourth inch diameter throwing rope one and one-half times the maximum width of the pool or fifty feet in length, whichever is less, to which has been firmly attached a ring buoy with an outside diameter of approximately fifteen inch
511-3-5-.18(10)(b) b) A minimum one-fourth inch diameter throwing rope one and one-half times the maximum width of the pool or fifty feet in length, whichever is less, to which has been firmly attached a ring buoy with an outside diameter of approximately fifteen inches or a similar flotation device which is U.S. Coast Guard approved.
511-3-5-.22(12) - (12) A safety self-inspection shall be conducted daily by the trained operator or responsible person and documented on a log sheet.
13-184(e)(5) Unsecured handrails considered an imminent health hazard-safety hazard. Informed CPO to repair and properly secure to provide reoccurrence.
#37 Violation: After reviewing the incident video an observation was noted about the pool surface light with color lens. Informed Manager to replace color lights with white lens (Only). Underwater Lighting. A minimum of one (1) watt underwater lighting per square foot of pool surface area shall be provided. Underwater light fixture shall be installed so as to effectively illuminate the entire pool.