May 15, 2026
Permit/Opening
19 - adequate turnover rate
13-190(a) Circulation equipment must provide adequate turnover rate. Turnover rate is not adequate. 6 hr turnover rate= 727 GPM. Observed flow meter at 265 GPM.
15 - depth and no diving markers, step marking; installed and contrasting
13-188(d)(1) Depth markers numbers and letters must be 4 inches tall. FT on depth tile is too small.
15 - depth and no diving markers, step marking; installed and contrasting
13-188(d)(1) No diving lettering too small. Must be a minimum of 2 inch lettering.