Re-inspection
Permit/Opening
13-190(a) Pumps shall function properly and be maintained in a clean condition. Observed pump # 2 making a loud noise and the other pump only working properly when one pump is shut off.
Permit/Opening
One missing/not working light inside pool.
Permit/Opening
13-202(m): Safety rules and regulations shall be easily readable and shall be conspicuously posted in the pool are. Rules must contain at a minimum the 12 statements in the pool code. Observed missing pool statements in pool rules.
Re-inspection
13-188(d)(1) - depth markers with black letters and numbers on a white background shall be at least 4 inches high. Observed depth marker letters not 4 inches high
Re-inspection
13-188(d)(1) - depth markers with black letters and numbers on a white background shall be at least 4 inches high. Observed depth marker letters not 4 inches high
13-189(c)(2) - cyanuric acid levels shall not exceed 100 ppm. Observed cyanuric acid levels 103, 108, 104
13-187(c) - operating permit shall be framed and displayed a close to the pool entrance as possible so that it is easily readable by the public at all times
Re-inspection
13-189(c)(1) Outdoor pool shall be maintained between 3ppm and 10ppm at all times. Observed FCL at 15.06
13-189(c)(1) - pool shall be maintained with a pH level between 7.2 and 7.8. Observed pH at 7.0.
13-188(D)(1) DEPTH MARKERS MUST BE AT LEAST 4 INCHES HIGH INDICATED IN FEET AND INCHES. SOME DEPTH MARKERS DID NOT HAVE "FT" AT LEAST 4 INCHES HIGH
13-202(I) EMERGENCY ACTION PLAN MUST BE COMPLETE WITH ALL REQUIRED SECTIONS. MISSING DRILL PROCEDURES
Routine
13-189(c)(1) Outdoor pool shall be maintained between 3ppm and 10ppm at all times. Observed FCL at 12.26. Retested at 11.79
13-189(c)(1) - pool shall be maintained with a pH level between 7.2 and 7.8. Observed pH at 7.0. Retested to 7.6
13-188(D)(1) DEPTH MARKERS MUST BE AT LEAST 4 INCHES HIGH INDICATED IN FEET AND INCHES. SOME DEPTH MARKERS DID NOT HAVE "FT" AT LEAST 4 INCHES HIGH
13-201(k) - at all times an adequate supply of liquid soap, toilet paper, and paper towels shall be provided. Observed bathrooms with no toilet paper or paper towels.
13-187(c) - current inspection report shall be displayed in a conspicuous place where it is easily readable by the public at all times
13-202(I) EMERGENCY ACTION PLAN MUST BE COMPLETE WITH ALL REQUIRED SECTIONS. MISSING DRILL PROCEDURES
13-187(c) - operating permit shall be framed and displayed in conspicuous place so it is easily readable by the public at all times
Permit/Opening
13-188(D)(1) DEPTH MARKERS MUST BE AT LEAST 4 INCHES HIGH INDICATED IN FEET AND INCHES. SOME DEPTH MARKERS DID NOT HAVE "FT" AT LEAST 4 INCHES HIGH
13-202(I) EMERGENCY ACTION PLAN MUST BE COMPLETE WITH ALL REQUIRED SECTIONS. MISSING DRILL PROCEDURES