Douglasville, Douglas County

CHAPEL HILL GOLF CLUB-POOL

3300 GOLF RIDGE BLVD DOUGLASVILLE, GA 30135

Pool
Latest score
81
Jun 4, 2026
City
Douglasville
County
Douglas
Inspections
4

Score history

Inspection scores over time for this facility.

Inspection history

Georgia inspection history is score-based, with violations grouped under each recorded inspection.

Jun 4, 2026

Permit/Opening

Score: 815 violations

36 - daily recordkeeping: water testing and self inspection performed

Regulation: 511-3-5-.22(1) - (1) all swimming pools and spas covered by this chapter shall be maintained under the supervision and direction of a properly trained operator who shall be responsible for the sanitation, safety, and proper maintenance of the pool and all related equ

5 ptsCorrected: NoRepeat: No

observed no daily record keeping ca; All swimming pools and spas covered by this Chapter shall be maintained under the supervision and direction of a properly trained operator who shall be responsible for the sanitation, safety, and proper maintenance of the pool and all related equipment, and for and daily recordkeeping.

17 - skimmers/gutters maintained and operable

Regulation: 511-3-5-.11(3)(d) - (d) each skimmer shall have a weir that adjusts automatically to variations in water level over a minimum range of four inches.

4 ptsCorrected: NoRepeat: No

OBSERVED A BROKEN SKIMMMER ANA A MIISING WEIR CA: Each skimmer shall have a weir that adjusts automatically to variations in water level over a minimum range of four inches. Skimmers should be in a good state of repair and maintainance.

26 - gauge(s) in proper location; sight glass installed

Regulation: 511-3-5-.07(4)(a) - (a) a pressure or vacuum gauge or other means of indicating system condition shall be provided in the circulation system in an easily readable location.

4 ptsCorrected: NoRepeat: No

observed a malfaunctional gauge : ca: A pressure or vacuum gauge or other means of indicating system condition shall be provided in the circulation system in an easily readable location

32 - operator training certification available onsite and approved

Regulation: 511-3-5-.22(2) - (2) the trained operator shall have a current certificate showing completion of an approved operator training course. a copy or the original certificate or documentation shall be available onsite for inspection by the health authority.

4 ptsCorrected: NoRepeat: No

observed no trainers certification onsite ca:The trained operator shall have a current certificate showing completion of an approved operator training course. A copy or the original certificate or documentation shall be available onsite for inspection by the Health Authority.

22 - signs: peak occupancy/pool/spa/signs legible and in clearview

Regulation: 511-3-5-.18(13)(c) - (c) a sign shall be posted stating the hours of operation in clear view near the entrance and shall state the theoretical peak occupancy.

2 ptsCorrected: NoRepeat: No

OBSERVED NO PEAK OCCUPANCE SIGN POSTED. CA: A sign shall be posted stating the hours of operation in clear view near the entrance and shall state the theoretical peak occupancy

May 21, 2025

Re-inspection

Score: 992 violations

37 - other violations of the chapter

1 ptsCorrected: NoRepeat: No

PUMP ROOM DOOR SHAL BE MADE OF EXTERIOR DOOR MATERIALS AND LUVERED. CA: REPLACE

37 - other violations of the chapter

1 ptsCorrected: NoRepeat: No

PUMP ROOM WET FROM WADE POOL DRAINAGE. CA: REPAIR.
WADE POOL IS CLOSED,

May 19, 2025

Permit/Opening

Score: 768 violations

6 - proper disinfectant level

Regulation: .17((1)(c) - proper disinfectant level

15 ptsCorrected: NoRepeat: No

DISINFECTANT OBSERVED AT 17. CA: MAINTAIN BETWEEN 2-10 PPM

7 - ph between 7.2 and 7.8

Regulation: 511-3-5-.17(2) - (2) chemical values: ph

15 ptsCorrected: NoRepeat: No

PH WAS OBSERVED ABOVE 8. CA: MAINTAIN PH 7.2-7.8.

28 - flow meter: appropriate range and location

Regulation: 511-3-5-.07(4)(b) - (b) a flow meter measuring the rate of flow through the filter system with an appropriate range readable in gallons per minute (gpm) and accurate within ten percent actual flow shall be provided. the flow indicator shall be capable of measuring from

5 ptsCorrected: NoRepeat: No

FLOW METER OBSERVED STUCK. CA: REPLACE OR REPAIR THE FLOW METER.

22 - signs: peak occupancy/pool/spa/signs legible and in clearview

Regulation: 511-3-5-.18(13)(c) - (c) a sign shall be posted stating the hours of operation in clear view near the entrance and shall state the theoretical peak occupancy.

2 ptsCorrected: NoRepeat: No

OBSERVED NO PHONE SIGN POSTED. OBSERVED NO PEAK OCCUPANCE SIGN POSTED. CA: POST SIGNS.

29 - toilets & lavatories: clean, maintained, and stocked

Regulation: 511-3-5-.19(2)(k) - (k) fixtures shall be designed so that they may be readily and frequently cleaned and

1 ptsCorrected: NoRepeat: No

WOMANS ROOM TOILET OBSERVED WITH WATER RUNNING. CA: REPAIR THE TOILET.

37 - other violations of the chapter

1 ptsCorrected: NoRepeat: No

OBSERVED WATER FOUNTAIN IN DISREPAIR. REPAIR OR MAKE FOUNTAIN SAFE.

37 - other violations of the chapter

1 ptsCorrected: NoRepeat: No

PUMP ROOM WET. CA: RELOCATE/CAP THE PIPE FORM THE BABY POOL SO IT IS NOT WETTING THE PUMP ROOM.

37 - other violations of the chapter

1 ptsCorrected: NoRepeat: No

PUMP ROOM HAS INTERIOR DOOR. CA: EXTERIOR DOORS THAT ARE LUVERED SHOULD BE USED.

May 30, 2024

Permit/Opening

Score: 1000 violations
No violations recorded for this inspection.