DOUGLASVILLE, Douglas County

Hampton Mill HOA

4400 HAMPTON MILL PKWY DOUGLASVILLE, GA 30135

Pool
Latest score
78
May 7, 2026
City
DOUGLASVILLE
County
Douglas
Inspections
7

Score history

Inspection scores over time for this facility.

Inspection history

Georgia inspection history is score-based, with violations grouped under each recorded inspection.

May 7, 2026

Permit/Opening

Score: 786 violations

28 - flow meter: appropriate range and location

Regulation: 511-3-5-.07(4)(b) - (b) a flow meter measuring the rate of flow through the filter system with an appropriate range readable in gallons per minute (gpm) and accurate within ten percent actual flow shall be provided. the flow indicator shall be capable of measuring from

5 ptsCorrected: NoRepeat: No

OBSERVED A NON-FUNCTIONAL LOW METER CA:Violation Code Reference 511-3-5-.07(4)(b) - (b) A flow meter measuring the rate of flow through the filter system with an appropriate range readable in gallons per minute (GPM) and accurate within ten percent actual flow shall be provided. The flow indicator shall be capable of measuring from (b) A flow meter measuring the rate of flow through the filter system with an appropriate range readable in gallons per minute (GPM) and accurate within ten percent actual flow shall be provided. The flow indicator shall be capable of measuring from one-half to at least one and one-half times the design flow rate. The gauge shall be located after the filtering equipment and in such location on the return line, so as to measure the total amount of water returning to the pool according to the manufacturer’s installation specifications.

Back to Top Back to Top | This page is being served from: CPDHJWHQ0QCFAA © Copyright 2026 Tyler Technologies All Rights Reserved.

15 - depth and no diving markers, step marking; installed and contrasting

Regulation: 511-3-5-.18(3)(h) - (h) depth markers number and letters shall be tile and four inches minimum in height. numbers shall be of contrasting color to the background on which they are applied.

4 ptsCorrected: NoRepeat: No

NO DIVING MARKERS WAS OBSERVED MISSING CA: 511-3-5-.18(3)(h) - (h) Depth markers number and letters shall be tile and four inches minimum in height. Numbers shall be of contrasting color to the background on which they are applied. (h) Depth markers number and letters shall be tile and four inches minimum in height. Numbers shall be of contrasting color to the background on which they are applied.

17 - skimmers/gutters maintained and operable

4 ptsCorrected: NoRepeat: No

OBSERVED MISSING WIERS. CA: REPLACE MISSING WIERS.

26 - gauge(s) in proper location; sight glass installed

Regulation: 511-3-5-.07(4)(a) - (a) a pressure or vacuum gauge or other means of indicating system condition shall be provided in the circulation system in an easily readable location.

4 ptsCorrected: NoRepeat: No

OBSERVED ALL THE GAUGES NOT FUNCTIONAL CA: 511-3-5-.07(4)(a) - (a) A pressure or vacuum gauge or other means of indicating system condition shall be provided in the circulation system in an easily readable location. (a) A pressure or vacuum gauge or other means of indicating system condition shall be provided in the circulation system in an easily readable location.

32 - operator training certification available onsite and approved

Regulation: 511-3-5-.22(2) - (2) the trained operator shall have a current certificate showing completion of an approved operator training course. a copy or the original certificate or documentation shall be available onsite for inspection by the health authority.

4 ptsCorrected: NoRepeat: No

OBSERVED THE OPERATIONAL CERTIFICATE NOT ONSITE CA:511-3-5-.22(2) - (2) The trained operator shall have a current certificate showing completion of an approved operator training course. A copy or the original certificate or documentation shall be available onsite for inspection by the Health Authority. (2) The trained operator shall have a current certificate showing completion of an approved operator training course. A copy or the original certificate or documentation shall be available onsite for inspection by the Health Authority.

37 - other violations of the chapter

1 ptsCorrected: NoRepeat: No

OBSERVED MISSING BOOT CAPS CA : BOOT CAPS TO BE OBTAINED and replaced

Aug 22, 2025

Routine

Score: 867 violations

17 - skimmers/gutters maintained and operable

4 ptsCorrected: NoRepeat: No

OBSERVED MISSING WIERS. CA: REPLACE MISSING WIERS.

21 - cyanuric acid level not exceeding maximum

4 ptsCorrected: NoRepeat: No

cyanuric acid was observed to be above 90 ppm ca: it should be maintained at 90 ppm and below

12 - grab/hand rails, ladders installed and secure

2 ptsCorrected: NoRepeat: No

OBSERVED BOOT CAPS MISSING ON THE LADDER. CA: REPLACE BOOOT CAPS.

22 - signs: peak occupancy/pool/spa/signs legible and in clearview

2 ptsCorrected: NoRepeat: No

OBSERVED NO PEAK OCCUPENCY SIGN. CA: REPLACE SIGN.

29 - toilets & lavatories: clean, maintained, and stocked

1 ptsCorrected: NoRepeat: No

THE RESTROOM WAS NOT ACCESSIBLE AT THE TIME OF INSPECTION

29 - toilets & lavatories: clean, maintained, and stocked

1 ptsCorrected: NoRepeat: No

THE RESTROOM WAS NOT ACCESSIBLE AT THE TIME OF INSPECTION

37 - other violations of the chapter

1 ptsCorrected: NoRepeat: No

OBSERVED MISSING BOOT CAPS CA : BOOT CAPS TO BE OBTAINED and replaced

Aug 20, 2025

Routine

Score: 776 violations

6 - proper disinfectant level

15 ptsCorrected: NoRepeat: No

Observed Chlorine levels too high at 11ppm. Chlorine must be between 2-10ppm

7 - ph between 7.2 and 7.8

15 ptsCorrected: NoRepeat: No

PH OBSERVED BELOW 7. CA: MAINTAIN PH BETWEEN 7.2 AND 7.8

17 - skimmers/gutters maintained and operable

4 ptsCorrected: NoRepeat: No

OBSERVED MISSING WIERS. CA: REPLACE MISSING WIERS.

12 - grab/hand rails, ladders installed and secure

2 ptsCorrected: NoRepeat: No

OBSERVED BOOT CAPS MISSING ON THE LADDER. CA: REPLACE BOOOT CAPS.

29 - toilets & lavatories: clean, maintained, and stocked

1 ptsCorrected: NoRepeat: No

THE RESTROOM WAS NOT ACCESSIBLE AT THE TIME OF INSPECTION

30 - deck/rinse shower maintained

1 ptsCorrected: NoRepeat: No

OBSERVED NO SHOWER ON PREMISES. CA: INSTALL SHOWER WITH HOT AND COLD WATER.

May 21, 2025

Re-inspection

Score: 907 violations

17 - skimmers/gutters maintained and operable

4 ptsCorrected: NoRepeat: No

OBSERVED MISSING WIERS. CA: REPLACE MISSING WIERS.

17 - skimmers/gutters maintained and operable

Regulation: 511-3-5-.11(3)(g) - (g) the skimmer equalizer lines shall be protected by an approved cover/grated with a flow rating equal the maximum system flow divided by the number of skimmers in the system or the maximum flow rating of the skimmer, whichever is greater.

4 ptsCorrected: NoRepeat: No

OBSERVED EQUALIZER LINES WITH NO VGB COMPLIANT COVERS. CA: REPLACE VGB COVERS.

12 - grab/hand rails, ladders installed and secure

Regulation: 511-3-5-.06(3)(f)1. - 1. handrails, if removable, shall be installed in such a way that they cannot be removed without the use of tools.

2 ptsCorrected: NoRepeat: No

OBSERVED BOOT CAPS MISSING ON THE LADDER. CA: REPLACE BOOOT CAPS.

12 - grab/hand rails, ladders installed and secure

Regulation: 511-3-5-.06(3)(f)1. - 1. handrails, if removable, shall be installed in such a way that they cannot be removed without the use of tools.

2 ptsCorrected: NoRepeat: No

OBSERVED HANDRAILS LOOSE. CA: TIGHTEN HANDRAILS.

22 - signs: peak occupancy/pool/spa/signs legible and in clearview

Regulation: 511-3-5-.18(13)(c) - (c) a sign shall be posted stating the hours of operation in clear view near the entrance and shall state the theoretical peak occupancy.

2 ptsCorrected: NoRepeat: No

OBSERVED NO PEAK OCCUPENCY SIGN. CA: REPLACE SIGN.

30 - deck/rinse shower maintained

Regulation: 511-3-5-.18(17) - (17) a minimum of one rinse shower shall be provided on the pool deck of all public pools and spas. water used for rinse showers may be at ambient temperature.

1 ptsCorrected: NoRepeat: No

OBSERVED NO SHOWER ON PREMISES. CA: INSTALL SHOWER WITH HOT AND COLD WATER.

37 - other violations of the chapter

1 ptsCorrected: NoRepeat: No

OBSERVED CLUB HOUSE REMODLES AND RESTROOMS REMOVED. ONLY ONE BATHROOM WITH TWO TOILETS REMAIN. CA: REPLACE RESTROOMS.

May 20, 2025

Re-inspection

Score: 726 violations

7 - ph between 7.2 and 7.8

Regulation: 511-3-5-.17(2) - (2) chemical values: ph

15 ptsCorrected: NoRepeat: No

PH OBSERVED BELOW 7. CA: MAINTAIN PH BETWEEN 7.2 AND 7.8

14 - vacuum line protected

Regulation: 511-3-5-.10(7) - (7) the vacuum line shall be protected with a self-closing, self-latching fitting that complies with the current iampo sps 4- special use suction fitting for swimming pools, spas and hot tubs.

5 ptsCorrected: NoRepeat: Yes

OBSERVED MO SAFETY COVER ON THE VACCUUM LINE. CA: INSTALL SAFETY COVER.

17 - skimmers/gutters maintained and operable

Regulation: 511-3-5-.11(3)(d) - (d) each skimmer shall have a weir that adjusts automatically to variations in water level over a minimum range of four inches.

4 ptsCorrected: NoRepeat: No

OBSERVED MISSING WIERS. CA: REPLACE MISSING WIERS.

12 - grab/hand rails, ladders installed and secure

2 ptsCorrected: NoRepeat: No

OBSERVED BOOT CAPS MISSING ON THE LADDER. CA: REPLACE BOOOT CAPS.

30 - deck/rinse shower maintained

Regulation: 511-3-5-.18(17) - (17) a minimum of one rinse shower shall be provided on the pool deck of all public pools and spas. water used for rinse showers may be at ambient temperature.

1 ptsCorrected: NoRepeat: No

OBSERVED NO SHOWER ON PREMISES. CA: INSTALL SHOWER WITH HOT AND COLD WATER.

37 - other violations of the chapter

1 ptsCorrected: NoRepeat: Yes

OBSERVED CLUB HOUSE REMODLES AND RESTROOMS REMOVED. ONLY ONE BATHROOM WITH TWO TOILETS REMAIN. CA: REPLACE RESTROOMS.

May 14, 2025

Permit/Opening

Score: 7011 violations

5 - emergency phone operational and accessible

Regulation: 511-3-5-.18(10)(c ) - (c) an operable, hard-wired, conventional telephone line or continuous powered source, weatherproof emergency phone shall be permanently installed in a conspicuous location within the pool enclosure and must be readily available to bathers at all tim

15 ptsCorrected: NoRepeat: No

0BSERVED 911 PHONE IS NOT OPERATIONAL. CA: REPAIR THE PHONE.

14 - vacuum line protected

Regulation: 511-3-5-.10(7) - (7) the vacuum line shall be protected with a self-closing, self-latching fitting that complies with the current iampo sps 4- special use suction fitting for swimming pools, spas and hot tubs.

5 ptsCorrected: NoRepeat: No

OBSERVED MO SAFETY COVER ON THE VACCUUM LINE. CA: INSTALL SAFETY COVER.

17 - skimmers/gutters maintained and operable

Regulation: 511-3-5-.11(3)(g) - (g) the skimmer equalizer lines shall be protected by an approved cover/grated with a flow rating equal the maximum system flow divided by the number of skimmers in the system or the maximum flow rating of the skimmer, whichever is greater.

4 ptsCorrected: NoRepeat: No

OBSERVED NO VGB COVERS ON EQUALIZER LINES. CA: OBTAIN AND INSTALL COVERS.

17 - skimmers/gutters maintained and operable

Regulation: 511-3-5-.11(3)(d) - (d) each skimmer shall have a weir that adjusts automatically to variations in water level over a minimum range of four inches.

4 ptsCorrected: NoRepeat: No

OBSERVE MISSING WIERS. CA: REPLACE WIERS.

12 - grab/hand rails, ladders installed and secure

Regulation: 511-3-5-.06(3)(f)1. - 1. handrails, if removable, shall be installed in such a way that they cannot be removed without the use of tools.

2 ptsCorrected: NoRepeat: No

OBSERVED BOOT CAPS MISSING ON THE LADDER. CA: REPLACE BOOOT CAPS.

12 - grab/hand rails, ladders installed and secure

Regulation: 511-3-5-.06(3)(f)1. - 1. handrails, if removable, shall be installed in such a way that they cannot be removed without the use of tools.

2 ptsCorrected: NoRepeat: No

OBSERVED HANDRAILS NOT SECURE. CA: REPAIR THE HANDRAILS.

22 - signs: peak occupancy/pool/spa/signs legible and in clearview

Regulation: 511-3-5-.18(12)(b) - (b) where no lifeguard is on duty, a sign or signs shall be placed in clear view at or near the entrance to the pool and shall state in clearly legible letters at least four inches high “warning - no life guard on duty and risk of drowning - supervis

2 ptsCorrected: NoRepeat: No

OBSERVED MISSING SIGNS WARNING NO LIFEGUARD. CA:REPLACE

22 - signs: peak occupancy/pool/spa/signs legible and in clearview

Regulation: 511-3-5-.18(13)(c) - (c) a sign shall be posted stating the hours of operation in clear view near the entrance and shall state the theoretical peak occupancy.

2 ptsCorrected: NoRepeat: No

OBSERVED NO PEAK OCCUPANCY SIGN. CA: REPLACE SIGN.

22 - signs: peak occupancy/pool/spa/signs legible and in clearview

Regulation: 511-3-5-.18(12)(c) - (c) the same sign in subsection (b) above or an additional sign will state under the heading “pool risks” the following items in clearly legible letters at least one inch high:

2 ptsCorrected: NoRepeat: No

POOL ROOL SIGN FLAT ON DECK. POOL RULE SIGNS MUST BE POSTED.

37 - other violations of the chapter

1 ptsCorrected: NoRepeat: No

OBSERVED CLUB HOUSE REMODLES AND RESTROOMS REMOVED. ONLY ONE BATHROOM WITH TWO TOILETS REMAIN. CA: REPLACE RESTROOMS.

30 - deck/rinse shower maintained

Regulation: 511-3-5-.18(17) - (17) a minimum of one rinse shower shall be provided on the pool deck of all public pools and spas. water used for rinse showers may be at ambient temperature.

1 ptsCorrected: NoRepeat: No

OBSERVED NO SHOWER ON PREMISES. CA: INSTALL SHOWER WITH HOT AND COLD WATER.

May 22, 2024

Permit/Opening

Score: 951 violation

28 - flow meter: appropriate range and location

5 ptsCorrected: NoRepeat: No

Flow meter broken. CA: Maintain Flow Meter