DOUGLASVILLE, Douglas County

Plantation at Dorsett Shoals HOA

4841 PLANTERS WALK DOUGLASVILLE, GA 30135

Pool
Latest score
95
May 18, 2026
City
DOUGLASVILLE
County
Douglas
Inspections
5

Score history

Inspection scores over time for this facility.

Inspection history

Georgia inspection history is score-based, with violations grouped under each recorded inspection.

May 18, 2026

Permit/Opening

Score: 952 violations

20 - return inlets maintained

4 ptsCorrected: NoRepeat: No

OBSERVED MISSING RETURN INLET COVERS CA:511-3-5-.10(1)(c )1.ii. - (ii) The fitting shall not constitute a hazard to the user. (ii) The fitting shall not constitute a hazard to the use

34 - inspection report placed in public view

1 ptsCorrected: NoRepeat: No

OBSERVED MISSING INSPECTION REPORT :CA:Violation Code Reference 511-3-5-.23(3)(d) - (d) The operator shall receive a copy of the inspection and place it in a location protected from the weather and in public view as designated by the health authority. (d) The operator shall receive a copy of the inspection and place it in a location protected from the weather and in public view as designated by the health authority.

May 4, 2026

Permit/Opening

Score: 804 violations

1 - barrier: pool enclosed/fencing in compliance

Regulation: 511-3-5-.18(11)(b) - (b) openings in the barrier shall not allow passage of a four inch diameter sphere.

15 ptsCorrected: YesRepeat: No

observed a gap of 6 inches at the pool fence ca:511-3-5-.18(11)(b) - (b) Openings in the barrier shall not allow passage of a four inch diameter sphere. (b) Openings in the barrier shall not allow passage of a four inch diameter sphere.

2 - self-closing / self-latching gates

Regulation: 511-3-5-.18(11)(h) - (h) access gates shall also comply with the requirements of this rule and shall be equipped to accommodate a locking device. barrier gates shall open away from the pool in facilities constructed after adoption of this chapter. pedestrian access gates

15 ptsCorrected: NoRepeat: No

observed the gate opening and closing mechanism unfunctional- could not open from the in towards outside ca:11-3-5-.18(11)(h) - (h) Access gates shall also comply with the requirements of this Rule and shall be equipped to accommodate a locking device. Barrier gates shall open away from the pool in facilities constructed after adoption of this chapter. Pedestrian access gates (h) Access gates shall also comply with the requirements of this Rule and shall be equipped to accommodate a locking device. Barrier gates shall open away from the pool in facilities constructed after adoption of this chapter. Pedestrian access gates shall be self-closing and have a self-latching device. Gates other than pedestrian access gates shall have a self-latching device. Where the release mechanism of the self latching device is located less than fifty-four inches from the bottom of the gate, 1. The release mechanism shall be located on the pool side of the gate at least three inches below the top of the gate and 2. Any openings in the gate or barrier located within eighteen inches of the release mechanism shall be less than one-half inch. 3. Mechanisms controlled by an access card reader, key entry device or keypad shall be located on the outside of the access gate.

20 - return inlets maintained

Regulation: 511-3-5-.10(1)(c )1.ii. - (ii) the fitting shall not constitute a hazard to the user.

4 ptsCorrected: NoRepeat: No

OBSERVED MISSING RETURN INLET COVERS CA:511-3-5-.10(1)(c )1.ii. - (ii) The fitting shall not constitute a hazard to the user. (ii) The fitting shall not constitute a hazard to the use

34 - inspection report placed in public view

Regulation: 511-3-5-.23(3)(d) - (d) the operator shall receive a copy of the inspection and place it in a location protected from the weather and in public view as designated by the health authority.

1 ptsCorrected: NoRepeat: No

OBSERVED MISSING INSPECTION REPORT :CA:Violation Code Reference 511-3-5-.23(3)(d) - (d) The operator shall receive a copy of the inspection and place it in a location protected from the weather and in public view as designated by the health authority. (d) The operator shall receive a copy of the inspection and place it in a location protected from the weather and in public view as designated by the health authority.

Jul 23, 2025

Routine

Score: 961 violation

17 - skimmers/gutters maintained and operable

4 ptsCorrected: NoRepeat: No

missing weirs were observed CA: replace missing weird

Jun 13, 2025

Permit/Opening

Score: 1000 violations
No violations recorded for this inspection.

May 30, 2024

Permit/Opening

Score: 1000 violations
No violations recorded for this inspection.