DOUGLASVILLE, Douglas County

LAKES AT STEWART MILL THE - MAIN

5300 LAKE BEECH DR DOUGLASVILLE, GA 30135

Pool
Latest score
95
Apr 30, 2026
City
DOUGLASVILLE
County
Douglas
Inspections
5

Score history

Inspection scores over time for this facility.

Inspection history

Georgia inspection history is score-based, with violations grouped under each recorded inspection.

Apr 30, 2026

Permit/Opening

Score: 952 violations

26 - gauge(s) in proper location; sight glass installed

Regulation: 511-3-5-.08(5) - (5) a sight glass shall be installed on the waste discharge line of pressure filters so that the progress of filter washing can be observed.

4 ptsCorrected: NoRepeat: No

Observed pressure gauges on both filters missing sight glass cover. Must be installed or replaced

37 - other violations of the chapter

1 ptsCorrected: NoRepeat: No

Observed surface files in pool are broken and corroded. Must be repaired or replaced

Mar 21, 2025

Permit/Opening

Score: 991 violation

29 - toilets & lavatories: clean, maintained, and stocked

Regulation: 511-3-5-.19(2)(i) - (i) soap, paper towels, and toilet tissue shall be provided in all dispensers.

1 ptsCorrected: NoRepeat: No

Observed no paper towels in women's restroom. Must be restocked

Aug 7, 2024

Re-inspection

Score: 961 violation

21 - cyanuric acid level not exceeding maximum

Regulation: 511-3-5-.17(4) - (4) stabilizer (if used) cyanuric acid,ppm ideal: 30-50 maximum: 90 comments: if stabilizer is: too high: - may reduce chlorine efficacy too low: - chlorine residual rapidly destroyed by sunlight note: stabilizer is not needed in indoor or br

4 ptsCorrected: NoRepeat: Yes

Observed CYA at 100ppm. CA: Stabilizer (if used) Cyanuric acid,ppm Ideal: 30-50 Maximum: 90

Aug 7, 2024

Routine

Score: 763 violations

8 - chemical feeder operational and approved

Regulation: 511-3-5-.16(2)(a) - (a) every pool and spa shall be required to have at least one unit of disinfectant agent equipment that introduces the agent through the circulation system in compliance with this rule

15 ptsCorrected: NoRepeat: No

Observed chlorine tablet in skimmer. CA: Every pool and spa shall be required to have at least one unit of disinfectant agent equipment that introduces the agent through the circulation system in compliance with this rule

28 - flow meter: appropriate range and location

Regulation: 511-3-5-.07(4)(b) - (b) a flow meter measuring the rate of flow through the filter system with an appropriate range readable in gallons per minute (gpm) and accurate within ten percent actual flow shall be provided. the flow indicator shall be capable of measuring from

5 ptsCorrected: NoRepeat: No

Observed flow meter float stuck at 0. CA: Flow meter must display proper GPM

21 - cyanuric acid level not exceeding maximum

Regulation: 511-3-5-.17(4) - (4) stabilizer (if used) cyanuric acid,ppm ideal: 30-50 maximum: 90 comments: if stabilizer is: too high: - may reduce chlorine efficacy too low: - chlorine residual rapidly destroyed by sunlight note: stabilizer is not needed in indoor or br

4 ptsCorrected: NoRepeat: No

Observed CYA above 100ppm. CA: Stabilizer (if used) Cyanuric acid,ppm Ideal: 30-50 Maximum: 90

Mar 22, 2024

Permit/Opening

Score: 1000 violations
No violations recorded for this inspection.