Lithia Springs, Douglas County

RESERVE AT SWEETWATER CREEK

99 CREEKSIDE CIR AUSTELL, GA 30168

Pool
Latest score
100
Apr 20, 2026
City
Lithia Springs
County
Douglas
Inspections
6

Score history

Inspection scores over time for this facility.

Inspection history

Georgia inspection history is score-based, with violations grouped under each recorded inspection.

Apr 20, 2026

Permit/Opening

Score: 1000 violations
No violations recorded for this inspection.

Sep 11, 2025

Re-inspection

Score: 852 violations

1 - barrier: pool enclosed/fencing in compliance

Regulation: 511-3-5-.18(11)(a) - (11) barriers. all outdoor swimming pools and spas shall be enclosed by a barrier to prevent entry to the pool area when the pool is closed. (a) the top of the barrier shall be at least forty eight inches above grade maesured on the side of the bar

15 ptsCorrected: NoRepeat: No

OBSERVED LARGE OPENINGS ALONG BOTTOM OF BARRIER. CA: Barriers. All outdoor swimming pools and spas shall be enclosed by a barrier to prevent entry to the pool area when the pool is closed. (a) The top of the barrier shall be at least forty eight inches above grade maesured on the side of the barried which faces away from the swiming pool. 1. The maximim vertical clearance between a solid surface and the bottom of the barrier shall be four inches measured on the side of the barrier which faces away from the swimming pool. 2. For non-solid surfaces, the veritical clearance between the bottom of the barrier and the grade shall not exceed two inches for a barrier constructed after adoption of the chapter. 3. Where the top of the pool structure is above grade, the barrier may be at ground level, such as the pool structure. 4. Where the barrier is mounted on top of the pool structure, the maximum vertical clearance between the top of the pool structure and the bottom of the barrier shall be four inches.

6 - proper disinfectant level

Regulation: .17((1)(c) - proper disinfectant level

15 ptsCorrected: NoRepeat: No

OBSERVED CHLORINE ABVE 10PPM. CA: AINTAIN LEVELS.

Aug 21, 2025

Routine

Score: 813 violations

1 - barrier: pool enclosed/fencing in compliance

Regulation: 511-3-5-.18(11)(a) - (11) barriers. all outdoor swimming pools and spas shall be enclosed by a barrier to prevent entry to the pool area when the pool is closed. (a) the top of the barrier shall be at least forty eight inches above grade maesured on the side of the bar

15 ptsCorrected: NoRepeat: No

OBSERVED LARGE OPENINGS ALONG BOTTOM OF BARRIER. CA: FIX BARRIER.

5 - emergency phone operational and accessible

Regulation: 511-3-5-.18(10)(c ) - (c) an operable, hard-wired, conventional telephone line or continuous powered source, weatherproof emergency phone shall be permanently installed in a conspicuous location within the pool enclosure and must be readily available to bathers at all tim

15 ptsCorrected: NoRepeat: No

OBSERVED EMERGENCY PHONE OPERATIONAL BUT ADDRESS IS NOT REGISTERED TO DEVICE FOR EMERGENCY PERSONEL. CA: FIX PHONE.

21 - cyanuric acid level not exceeding maximum

Regulation: 511-3-5-.17(4) - (4) stabilizer (if used) cyanuric acid,ppm ideal: 30-50 maximum: 90 comments: if stabilizer is: too high: - may reduce chlorine efficacy too low: - chlorine residual rapidly destroyed by sunlight note: stabilizer is not needed in indoor or br

4 ptsCorrected: NoRepeat: No

OBSERVED CYA ABOVE 90 PPM. CA: MAINTAIN CYA.

May 20, 2024

Permit/Opening

Score: 1000 violations
No violations recorded for this inspection.

Aug 18, 2023

Re-inspection

Score: 961 violation

20 - return inlets maintained

Regulation: 511-3-5-.10(1)(c )1.ii. - (ii) the fitting shall not constitute a hazard to the user.

4 ptsCorrected: NoRepeat: No

Observed one return cover in need of repair.. CA: replace return cover.

Aug 11, 2023

Permit/Opening

Score: 846 violations

36 - daily recordkeeping: water testing and self inspection performed

Regulation: 511-3-5-.22(9) - (9) water testing frequency. the trained operator or responsible person shall collect water samples from the water in the pool for monitoring. an in-line sampling port may be used for water held in reservoirs. the water quality testing frequency shal

5 ptsCorrected: NoRepeat: No

Observed daily log out of Date. CA: maintain daily log.

20 - return inlets maintained

Regulation: 511-3-5-.10(1)(c )1.ii. - (ii) the fitting shall not constitute a hazard to the user.

4 ptsCorrected: NoRepeat: No

Observed one return cover in need of repair.. CA: replace return cover.

12 - grab/hand rails, ladders installed and secure

Regulation: 511-3-5-.06(3)(f)1. - 1. handrails, if removable, shall be installed in such a way that they cannot be removed without the use of tools.

2 ptsCorrected: NoRepeat: No

Observed 2 stair rails that need to be tightened. CA: tighten star rails.

16 - pool deck: maintained, unobstructed and clean

Regulation: 511-3-5-.06(1)(l) - (l) open joints or gaps larger than three-sixteenths inch wide or with vertical elevations exceeding 1/4 inches shall be rectified using appropriate fillers. construction joints where pool coping meets the decks shall be watertight and shall not allo

2 ptsCorrected: NoRepeat: No

Observed several areas of the pool deck in need of repair. CA: repair.

22 - signs: peak occupancy/pool/spa/signs legible and in clearview

Regulation: 511-3-5-.18(12)(c) - (c) the same sign in subsection (b) above or an additional sign will state under the heading “pool risks” the following items in clearly legible letters at least one inch high:

2 ptsCorrected: NoRepeat: No

Incorrect sign for pool rules. CA: Apply correct signage.

37 - other violations of the chapter

1 ptsCorrected: NoRepeat: No

Observed light fixture hanging on the outside of the pool which is a possible hazard. Pool CANNOT open until lighting is fixed and re-inspection has occurred. CA: Replace/repair light fixture.