Mar 12, 2026
Permit/Opening
200 PEBBLESTONE DR BLOOMINGDALE, GA 31302
Inspection scores over time for this facility.
Georgia inspection history is score-based, with violations grouped under each recorded inspection.
Permit/Opening
Routine
Observed calcium hardness at 63 ppm, lower than the required minimum 150 ppm.
Permit/Opening
Routine
Permit/Opening
Routine
Regulation: 511-3-5-.17(1) - (1) disinfectant levels (a) free chlorine, ppm in pools not using cyanuric acid or a stabilized chlorine compound use (b),1.-5.
Observed combined chlorine at 1.17 ppm, higher than the required maximum .4 ppm.
Regulation: 511-3-5-.17(4) - (4) stabilizer (if used) cyanuric acid,ppm ideal: 30-50 maximum: 90 comments: if stabilizer is: too high: - may reduce chlorine efficacy too low: - chlorine residual rapidly destroyed by sunlight note: stabilizer is not needed in indoor or br
Observed cyanuric acid at 95 ppm, higher than the required maximum 90 ppm.
Observed total alkalinity at 48 ppm, lower than the required minimum 60 ppm.