Fayetteville, Fayette County

Azalea Estates Indoor Pool

105 AUTUMN GLEN CIR FAYETTEVILLE, GA 30215

Pool
Latest score
84
May 28, 2026
City
Fayetteville
County
Fayette
Inspections
6

Score history

Inspection scores over time for this facility.

Inspection history

Georgia inspection history is score-based, with violations grouped under each recorded inspection.

May 28, 2026

Permit/Opening

Score: 847 violations

36 - daily recordkeeping: water testing and self inspection performed

Regulation: 511-3-5-.22(12) - (12) a safety self-inspection shall be conducted daily by the trained operator or responsible person and documented on a log sheet.

5 ptsCorrected: NoRepeat: No

There is no available documentation to verify a daily safety check is conducted. A safety self-inspection shall be conducted daily by the trained operator or responsible person and documented on a log sheet. See CPO Guidance Docs.

36 - daily recordkeeping: water testing and self inspection performed

Regulation: 511-3-5-.22(9) - (9) water testing frequency. the trained operator or responsible person shall collect water samples from the water in the pool for monitoring. an in-line sampling port may be used for water held in reservoirs. the water quality testing frequency shal

5 ptsCorrected: NoRepeat: No

The daily testing does not include the chlorine levels for each day the pool is open. The chlorine and pH must be tested twice daily for pools. The trained operator or responsible person shall collect water samples from the water in the pool for monitoring. The water quality testing frequency shall be as indicated in the CPO guidance document. See email

15 - depth and no diving markers, step marking; installed and contrasting

Regulation: 511-3-5-.18(3)(h) - (h) depth markers number and letters shall be tile and four inches minimum in height. numbers shall be of contrasting color to the background on which they are applied.

4 ptsCorrected: NoRepeat: No

The letters on the depth markers do not meet minimum height requirement of 4". Depth markers number and letters shall be tile and four inches minimum in height. Numbers shall be of contrasting color to the background on which they are applied. Correct prior to permitting season 2028

32 - operator training certification available onsite and approved

Regulation: 511-3-5-.22(2) - (2) the trained operator shall have a current certificate showing completion of an approved operator training course. a copy or the original certificate or documentation shall be available onsite for inspection by the health authority.

4 ptsCorrected: NoRepeat: No

There is no available documentation to show there is a current, certified CPO associated with the pool. The trained operator shall have a current certificate showing completion of an approved operator training course. A copy of the original certificate or documentation shall be available onsite for inspection by the Health Authority.

22 - signs: peak occupancy/pool/spa/signs legible and in clearview

Regulation: 511-3-5-.18(12)(a) - (a) the words "no diving" and the universal international symbol for “no diving” shall be permanently visible at the edge of the deck for water five feet in depth or less, placed only on the deck beside the depth markers, and shall conform to that ou

2 ptsCorrected: NoRepeat: No

The words "No Diving" does not meet the minimum height requirements for the depth markers.The words "No Diving" and the universal international symbol for “NO DIVING” shall be permanently visible at the edge of the deck for water five feet in depth or less, placed only on the deck beside the depth markers, and shall conform to that outlined for depth markers. Correct prior to permitting 2028.

37 - other violations of the chapter

1 ptsCorrected: NoRepeat: No

.04(9)(d) There are some side rails missing inside the pool (not required by code), but the screws are still present and are sticking out. Remove screws or replace handrails to prevent injury to bathers. All surfaces that come in contact with the user shall be finished so that they do not constitute a cutting, pinching, puncturing or abrasion hazard under casual contact and intended use. All materials shall be maintained in accordance with manufacturer's instructions.

37 - other violations of the chapter

1 ptsCorrected: NoRepeat: No

.13(2)(b) There is no documentation to verify the annual gas fired inspection is performed. An annual gas fired inspections shall be performed by a qualified professional. Manager indicates she has not found a company yet. She will contact a local hotel since gas fired inspections are required at most.

Jul 15, 2025

Permit/Opening

Score: 817 violations

28 - flow meter: appropriate range and location

Regulation: 511-3-5-.07(4)(b) - (b) a flow meter measuring the rate of flow through the filter system with an appropriate range readable in gallons per minute (gpm) and accurate within ten percent actual flow shall be provided. the flow indicator shall be capable of measuring from

5 ptsCorrected: NoRepeat: No

Observed that the flow meter was not moving/non-operational. CA: There shall be a working flow meter to show the flow through the system.

36 - daily recordkeeping: water testing and self inspection performed

Regulation: 511-3-5-.22(12) - (12) a safety self-inspection shall be conducted daily by the trained operator or responsible person and documented on a log sheet.

5 ptsCorrected: NoRepeat: No

Observed that the facility did not have their daily safety check records. CA: Facility shall conducted daily safety checks and have those records available.

36 - daily recordkeeping: water testing and self inspection performed

Regulation: 511-3-5-.22(9) - (9) water testing frequency. the trained operator or responsible person shall collect water samples from the water in the pool for monitoring. an in-line sampling port may be used for water held in reservoirs. the water quality testing frequency shal

5 ptsCorrected: NoRepeat: No

Observed that the facility did not have their daily chemical check records. CA: Facility shall conducted daily chemical checks and have those records available.

17 - skimmers/gutters maintained and operable

Regulation: 511-3-5-.11(3)(g) - (g) the skimmer equalizer lines shall be protected by an approved cover/grated with a flow rating equal the maximum system flow divided by the number of skimmers in the system or the maximum flow rating of the skimmer, whichever is greater.

4 ptsCorrected: NoRepeat: No

Observed that there were no check valves or float valve assembly in skimmer. CA: Skimmer equalizer lines shall be protected by an approved cover.

17 - skimmers/gutters maintained and operable

Regulation: 511-3-5-.11(3)(d) - (d) each skimmer shall have a weir that adjusts automatically to variations in water level over a minimum range of four inches.

4 ptsCorrected: NoRepeat: No

Observed that there were no weirs present in the skimmers. CA: Each skimmer shall have a weir that adjusts automatically to variations in water level over a minimum range of four inches.

35 - operator facility inspections performed; written documentation

Regulation: 511-3-5-.22(6) - (6) written documentation of the operator’s visits must be available at the pool facility. at a minimum, the written record must indicate the condition of the following items:

4 ptsCorrected: NoRepeat: No

The documents for the CPO visits are not available. CA: Documentation for the CPO visits showing checks of all required items shall be available.

37 - other violations of the chapter

1 ptsCorrected: NoRepeat: No

.13(2)(b) - Observed that the facility has a heated pool, however, they do not have evidence of gas fired equipment inspection. CA: Facility shall have evidence of a yearly gas fired equipment inspection done on the pool heater.

Jul 14, 2025

Permit/Opening

Score: 668 violations

2 - self-closing / self-latching gates

Regulation: 511-3-5-.18(11)(h) - (h) access gates shall also comply with the requirements of this rule and shall be equipped to accommodate a locking device. barrier gates shall open away from the pool in facilities constructed after adoption of this chapter. pedestrian access gates

15 ptsCorrected: NoRepeat: No

Observed that the pool was closed at this time, however, one of the doors does not have a handle and allows entry into the pool. CA: Pools shall be enclosed by a barrier that prevents entry when the pool is closed.

11 - appropriate lifesaving equipment present

Regulation: 511-3-5-.18(10)(b) - (b) a minimum one-fourth inch diameter throwing rope one and one-half times the maximum width of the pool or fifty feet in length, whichever is less, to which has been firmly attached a ring buoy with an outside diameter of approximately fifteen inch

15 ptsCorrected: NoRepeat: No

Observed that the ring bouy was not coast guard compliant and did not have a rope attached. CA: Facility shall have a ring bouy with a minimum of one-fourth inch diameter throwing rope that is at least one-half the length of pool with it attached to the ring bouy.

28 - flow meter: appropriate range and location

Regulation: 511-3-5-.07(4)(b) - (b) a flow meter measuring the rate of flow through the filter system with an appropriate range readable in gallons per minute (gpm) and accurate within ten percent actual flow shall be provided. the flow indicator shall be capable of measuring from

5 ptsCorrected: NoRepeat: No

Observed that the flow meter was not moving/non-operational. CA: There shall be a working flow meter to show the flow through the system.

36 - daily recordkeeping: water testing and self inspection performed

Regulation: 511-3-5-.22(12) - (12) a safety self-inspection shall be conducted daily by the trained operator or responsible person and documented on a log sheet.

5 ptsCorrected: NoRepeat: No

Observed that the facility did not have their daily safety check records. CA: Facility shall conducted daily safety checks and have those records available.

36 - daily recordkeeping: water testing and self inspection performed

Regulation: 511-3-5-.22(9) - (9) water testing frequency. the trained operator or responsible person shall collect water samples from the water in the pool for monitoring. an in-line sampling port may be used for water held in reservoirs. the water quality testing frequency shal

5 ptsCorrected: NoRepeat: No

Observed that the facility did not have their daily chemical check records. CA: Facility shall conducted daily chemical checks and have those records available.

17 - skimmers/gutters maintained and operable

Regulation: 511-3-5-.11(3)(g) - (g) the skimmer equalizer lines shall be protected by an approved cover/grated with a flow rating equal the maximum system flow divided by the number of skimmers in the system or the maximum flow rating of the skimmer, whichever is greater.

4 ptsCorrected: NoRepeat: No

Observed that there were no check valves or float valve assembly in skimmer. CA: Skimmer equalizer lines shall be protected by an approved cover.

35 - operator facility inspections performed; written documentation

Regulation: 511-3-5-.22(6) - (6) written documentation of the operator’s visits must be available at the pool facility. at a minimum, the written record must indicate the condition of the following items:

4 ptsCorrected: NoRepeat: No

The documents for the CPO visits are not available. CA: Documentation for the CPO visits showing checks of all required items shall be available.

37 - other violations of the chapter

1 ptsCorrected: NoRepeat: No

.13(2)(b) - Observed that the facility has a heated pool, however, they do not have evidence of gas fired equipment inspection. CA: Facility shall have evidence of a yearly gas fired equipment inspection done on the pool heater.

Oct 10, 2024

Routine

Score: 1000 violations
No violations recorded for this inspection.

Jun 11, 2024

Routine

Score: 1000 violations
No violations recorded for this inspection.

Sep 22, 2023

Routine

Score: 1000 violations
No violations recorded for this inspection.