FAYETTEVILLE, Fayette County

Royal Ridge Homeowners Association

ROYAL RIDGE WAY FAYETTEVILLE, GA 30215

Pool
Latest score
79
May 13, 2026
City
FAYETTEVILLE
County
Fayette
Inspections
7

Score history

Inspection scores over time for this facility.

Inspection history

Georgia inspection history is score-based, with violations grouped under each recorded inspection.

May 13, 2026

Permit/Opening

Score: 793 violations

5 - emergency phone operational and accessible

Regulation: 511-3-5-.18(10)(c ) - (c) an operable, hard-wired, conventional telephone line or continuous powered source, weatherproof emergency phone shall be permanently installed in a conspicuous location within the pool enclosure and must be readily available to bathers at all tim

15 ptsCorrected: NoRepeat: No

The emergency phone has been relocated within the enclosure. However, the installed box goes to a third party entity instead of directly to 911. This must be corrected prior to the routine inspection this season or the pool must remain closed until it is corrected. An operable, hard-wired, conventional telephone line or continuous powered source, weatherproof emergency phone shall be permanently installed in a conspicuous location within the pool enclosure and must be readily available to bathers at all times. The emergency phone shall be capable of connecting to 911 and electronically transferring an automatic number identification and automatic locator identification of the pool emergency phone to the public safety answering point, if available. A 911 sign or the names and phone numbers of the nearest available police, fire, ambulance service or rescue unit shall be posted nearby.

15 - depth and no diving markers, step marking; installed and contrasting

Regulation: 511-3-5-.18(3)(h) - (h) depth markers number and letters shall be tile and four inches minimum in height. numbers shall be of contrasting color to the background on which they are applied.

4 ptsCorrected: NoRepeat: No

The letters on the depth markers on deck and pool wall do not meet minimum height requirement of 4". Depth markers are not present on tile. The markers are painted on in black paint. Depth markers number and letters shall be tile and four inches minimum in height. Numbers shall be of contrasting color to the background on which they are applied. Correct prior to permitting season 2028

22 - signs: peak occupancy/pool/spa/signs legible and in clearview

Regulation: 511-3-5-.18(12)(a) - (a) the words "no diving" and the universal international symbol for “no diving” shall be permanently visible at the edge of the deck for water five feet in depth or less, placed only on the deck beside the depth markers, and shall conform to that ou

2 ptsCorrected: NoRepeat: No

The words No Diving are not permanent in nature on the pool deck; painted on. There is no universal symbol for No diving present. The words "No Diving" and the universal international symbol for “NO DIVING” shall be permanently visible at the edge of the deck for water five feet in depth or less, placed only on the deck beside the depth markers, and shall conform to that outlined for depth markers. Correct prior to permitting 2028.

Sep 12, 2025

Routine

Score: 6714 violations

1 - barrier: pool enclosed/fencing in compliance

Regulation: 511-3-5-.23(5)(g) - (g) failure to provide and maintain a barrier to inhibit unauthorized access to the outdoor facility when required.

15 ptsCorrected: NoRepeat: No

The pool gate does not complete close and latch back when opened at different angles. The pool gate must self close and self latch to prevent unauthorized access to the pool enclosure.

5 - emergency phone operational and accessible

Regulation: 511-3-5-.18(10)(c ) - (c) an operable, hard-wired, conventional telephone line or continuous powered source, weatherproof emergency phone shall be permanently installed in a conspicuous location within the pool enclosure and must be readily available to bathers at all tim

15 ptsCorrected: NoRepeat: No

The emergency phone is installed on the exterior of the pool gate. Prior to next season, the emergency phone must be installed inside the pool barrier. An operable, hard-wired, conventional telephone line or continuous powered source, weatherproof emergency phone shall be permanently installed in a conspicuous location within the pool enclosure and must be readily available to bathers at all times. The emergency phone shall be capable of connecting to 911 and electronically transferring an automatic number identification and automatic locator identification of the pool emergency phone to the public safety answering point, if available. A 911 sign or the names and phone numbers of the nearest available police, fire, ambulance service or rescue unit shall be posted nearby.

5 - emergency phone operational and accessible

Regulation: 511-3-5-.18(10)(c ) - (c) an operable, hard-wired, conventional telephone line or continuous powered source, weatherproof emergency phone shall be permanently installed in a conspicuous location within the pool enclosure and must be readily available to bathers at all tim

15 ptsCorrected: NoRepeat: No

The emergency phone does not go directly to 911 emergency when the call box is activated. Facility has until next season to correct. The emergency phone shall be capable of connecting to 911 and electronically transferring an automatic number identification and automatic locator identification of the pool emergency phone to the public safety answering point.

11 - appropriate lifesaving equipment present

Regulation: 511-3-5-.23(5)(h) - (h) absence of required lifesaving equipment on the deck or an emergency phone;

15 ptsCorrected: NoRepeat: No

The body hook is not securely attached to the strong pole. Ensure the body hook remains attached to the strong pole at all times.

11 - appropriate lifesaving equipment present

Regulation: 511-3-5-.18(10)(b) - (b) a minimum one-fourth inch diameter throwing rope one and one-half times the maximum width of the pool or fifty feet in length, whichever is less, to which has been firmly attached a ring buoy with an outside diameter of approximately fifteen inch

15 ptsCorrected: NoRepeat: No

The ring buoy is not Coast Guard Approved. A minimum one-fourth inch diameter throwing rope one and one-half times the maximum width of the pool or fifty feet in length, whichever is less, to which has been firmly attached a ring buoy with an outside diameter of approximately fifteen inches or a similar flotation device which is U.S. Coast Guard approved.

36 - daily recordkeeping: water testing and self inspection performed

Regulation: 511-3-5-.22(12) - (12) a safety self-inspection shall be conducted daily by the trained operator or responsible person and documented on a log sheet.

5 ptsCorrected: NoRepeat: No

There are no available records onsite to verify a daily safety self check is performed. A safety self-inspection shall be conducted daily by the trained operator or responsible person and documented on a log sheet.

36 - daily recordkeeping: water testing and self inspection performed

Regulation: 511-3-5-.22(9) - (9) water testing frequency. the trained operator or responsible person shall collect water samples from the water in the pool for monitoring. an in-line sampling port may be used for water held in reservoirs. the water quality testing frequency shal

5 ptsCorrected: NoRepeat: No

There is no available documentation to verify that the required chemicals are testing according to the code.

35 - operator facility inspections performed; written documentation

Regulation: 511-3-5-.22(6) - (6) written documentation of the operator’s visits must be available at the pool facility. at a minimum, the written record must indicate the condition of the following items:

4 ptsCorrected: NoRepeat: No

There is no available documentation onsite to indicate the visits made byt the CPO. Written documentation of the operator’s visits must be available at the pool facility. At a minimum, the written record must indicate the conditions of the pool as required.

15 - depth and no diving markers, step marking; installed and contrasting

Regulation: 511-3-5-.18(4) - (4) depth markers for spas. public spas shall have permanent depth markers with numbers and letters a minimum of four inches high plainly and conspicuously visible from all obvious points of entry and in conformance with subsections (a) thru (f) belo

4 ptsCorrected: NoRepeat: No

There is no "FT" marking beside the depth markers. Each depth marker must have the number and letters that are 4" in height.

16 - pool deck: maintained, unobstructed and clean

Regulation: 511-3-5-.06(1)(f) - (f) the deck, including coping, shall have a minimum four feet width of continuous, unobstructed walking area maintained at all times unless otherwise allowed in the chapter.

2 ptsCorrected: NoRepeat: No

There are pieces of pool furniture too close to the pool edge. The deck, including coping, shall have a minimum four feet width of continuous, unobstructed walking area maintained at all times.

22 - signs: peak occupancy/pool/spa/signs legible and in clearview

Regulation: 511-3-5-.18(13)(c) - (c) a sign shall be posted stating the hours of operation in clear view near the entrance and shall state the theoretical peak occupancy.

2 ptsCorrected: NoRepeat: No

The bather load is not posted. A sign shall be posted stating the hours of operation in clear view near the entrance and shall state the theoretical peak occupancy.

22 - signs: peak occupancy/pool/spa/signs legible and in clearview

Regulation: 511-3-5-.18(12)(c) - (c) the same sign in subsection (b) above or an additional sign will state under the heading “pool risks” the following items in clearly legible letters at least one inch high:

2 ptsCorrected: NoRepeat: No

The pool rules sign posted is not the correct list of pool risks. Ensure the proper list of required risks are posted and meet the minimum required sizing. The sign will have the heading “Pool Risks” in clearly legible letters at least one inch high.

22 - signs: peak occupancy/pool/spa/signs legible and in clearview

Regulation: 511-3-5-.18(12)(b) - (b) where no lifeguard is on duty, a sign or signs shall be placed in clear view at or near the entrance to the pool and shall state in clearly legible letters at least four inches high “warning - no life guard on duty and risk of drowning - supervis

2 ptsCorrected: NoRepeat: No

The posted No lifeguard on duty sign does not meet the requirements of the code. Where no lifeguard is on duty, a sign or signs shall be placed in clear view at or near the entrance to the pool and shall state in clearly legible letters at least four inches high “WARNING - NO LIFE GUARD ON DUTY and RISK OF DROWNING - SUPERVISE CHILDREN CLOSELY”.

37 - other violations of the chapter

1 ptsCorrected: NoRepeat: No

The equalizer check valve and the float valve assembly (trimmer valve) is not present in each skimmer. Each skimmer shall be equipped with a trimmer valve capable of distributing the total flow between individual skimmers.

May 16, 2025

Permit/Opening

Score: 1000 violations
No violations recorded for this inspection.

Jul 29, 2024

Routine

Score: 961 violation

15 - depth and no diving markers, step marking; installed and contrasting

Regulation: .06(3)(e) - markings

4 ptsCorrected: NoRepeat: No

Remark no diving on pool deck.

May 16, 2024

Permit/Opening

Score: 1000 violations
No violations recorded for this inspection.

Jul 28, 2023

Routine

Score: 1000 violations
No violations recorded for this inspection.

Jun 5, 2023

Permit/Opening

Score: 1000 violations
No violations recorded for this inspection.