Mar 20, 2026

Permit/Opening

Score: 745 violations

2 - self-closing / self-latching gates

Regulation: 511-3-5-.18(11)(h) - (h) access gates shall also comply with the requirements of this rule and shall be equipped to accommodate a locking device. barrier gates shall open away from the pool in facilities constructed after adoption of this chapter. pedestrian access gates

15 ptsCorrected: NoRepeat: No

There is no gate or other method of prevention from unauthorized access into the pool area from the locker rooms. The facility will have until next routine inspection to correct. Access gates shall also comply with the requirements of this Rule and shall be equipped to accommodate a locking device. Barrier gates shall open away from the pool in facilities constructed after adoption of this chapter. Pedestrian access gates shall be self-closing and have a self-latching device. Gates other than pedestrian access gates shall have a self-latching device. Where the release mechanism of the self latching device is located less than fifty-four inches from the bottom of the gate, 1. The release mechanism shall be located on the pool side of the gate at least three inches below the top of the gate and 2. Any openings in the gate or barrier located within eighteen inches of the release mechanism shall be less than one-half inch. 3. Mechanisms controlled by an access card reader, key entry device or keypad shall be located on the outside of the access gate.

19 - adequate turnover rate

Regulation: 511-3-5-.07(1)(a) - (a) the equipment for a swimming pool shall be of adequate size to turn over the entire pool water capacity. the turnover rate for pools constructed after the adoption of this chapter shall not exceed the sum of one and one-half times the average wat

5 ptsCorrected: NoRepeat: Yes

The required turnover is not met. The pool must turnover 165 gpm. The pressure on the filters is high and most likely needs to be backwashed. Ensure filters and other equipment is properly maintained so turnover rate can be met. If the turnover is not met at next inspection, then filtration equipment may need to be investigated and changed as needed to ensure proper turnover rate. The equipment for a swimming pool shall be of adequate size to turn over the entire pool water capacity. The turnover rate for pools constructed after the adoption of this chapter shall not exceed the sum of one and one-half times the average water depth in feet; where the number of hours is equal to the number feet calculated, or exceed once every six hours whichever is less. Unless the rate is otherwise specified in subsection (b) below. This system shall be designed to give the proper turnover rate based on the manufacturer's recommended maximum pressure flow of the filter in dirty media condition of the filter, immediately prior to cleaning the filter.

36 - daily recordkeeping: water testing and self inspection performed

Regulation: 511-3-5-.22(12) - (12) a safety self-inspection shall be conducted daily by the trained operator or responsible person and documented on a log sheet.

5 ptsCorrected: NoRepeat: Yes

There is no documentation available onsite to verify a daily safety self check is performed. A safety self-inspection shall be conducted daily by the trained operator or responsible person and documented on a log sheet.

37 - other violations of the chapter

1 ptsCorrected: NoRepeat: No

.22(13) All public swimming pools shall have a written contamination response plan for responding to incidents of formed-stool, diarrheal-stool, and vomitus contamination. Such incidents shall be recorded and managed by the trained operator or responsible person as follows: (a) A log shall be maintained to record each occurrence of contamination in the water or on the adjacent deck area for formed or diarrheal fecal material, whole stomach discharge of vomitus, and blood. (b) After an incident, the public swimming pool will be closed for the time required to achieve the correct contact concentration and time (CT) value (CT, mg-min/L) for the hazard, in accordance with the most recent recommendations published by the Centers for Disease Control and Prevention.

37 - other violations of the chapter

1 ptsCorrected: NoRepeat: Yes

.13(2)(b): There is no documentation to verify an annual gas fired inspection has been performed on the pool heater. An annual gas fired inspections shall be performed by a qualified professional. Correct prior to follow up inspection.

Mar 6, 2026

Permit/Opening

Score: 757 violations

14 - vacuum line protected

Regulation: 511-3-5-.10(7) - (7) the vacuum line shall be protected with a self-closing, self-latching fitting that complies with the current iampo sps 4- special use suction fitting for swimming pools, spas and hot tubs.

5 ptsCorrected: NoRepeat: No

The vacuum line does not have a cover over the line. The vacuum line shall be protected with a self-closing, self-latching fitting that complies with the current IAMPO SPS 4- Special Use Suction Fitting for Swimming Pools, Spas and Hot Tubs.

18 - combined chlorine level 0.4 ppm or less

Regulation: 511-3-5-.17(1) - (1) disinfectant levels (a) free chlorine, ppm in pools not using cyanuric acid or a stabilized chlorine compound use (b),1.-5.

5 ptsCorrected: NoRepeat: No

The combined chlorine in the pool exceeds the allowable .4 ppm. Shock pool to reduce combined chlorine.

19 - adequate turnover rate

Regulation: 511-3-5-.07(1)(a) - (a) the equipment for a swimming pool shall be of adequate size to turn over the entire pool water capacity. the turnover rate for pools constructed after the adoption of this chapter shall not exceed the sum of one and one-half times the average wat

5 ptsCorrected: NoRepeat: No

The required turnover is not met. The pool must turnover 165 gpm. The pressure on the filters is high and most likely needs to be backwashed. Ensure filters and other equipment is properly maintained so turnover rate can be met.

36 - daily recordkeeping: water testing and self inspection performed

Regulation: 511-3-5-.22(12) - (12) a safety self-inspection shall be conducted daily by the trained operator or responsible person and documented on a log sheet.

5 ptsCorrected: NoRepeat: No

There is no documentation available onsite to verify a daily safety self check is performed. A safety self-inspection shall be conducted daily by the trained operator or responsible person and documented on a log sheet.

36 - daily recordkeeping: water testing and self inspection performed

Regulation: 511-3-5-.22(9) - (9) water testing frequency. the trained operator or responsible person shall collect water samples from the water in the pool for monitoring. an in-line sampling port may be used for water held in reservoirs. the water quality testing frequency shal

5 ptsCorrected: NoRepeat: No

There is no documentation indicating the pool chemicals are tested per requirement. For pools, free available chlorine or total bromine and pH shall be tested a minimum of two times daily during the hours of operation. (b) Total alkalinity shall be tested weekly and calcium hardness shall be tested monthly. (c) If stabilized chlorine is used as the primary disinfectant, the operator shall test cyanuric acid every two weeks. Otherwise, cyanuric acid shall be tested monthly.

35 - operator facility inspections performed; written documentation

Regulation: 511-3-5-.22(6) - (6) written documentation of the operator’s visits must be available at the pool facility. at a minimum, the written record must indicate the condition of the following items:

4 ptsCorrected: NoRepeat: No

There is no documentation available for each visit made by the CPO. Written documentation of the operator’s visits must be available at the pool facility. At a minimum, the written record must indicate the condition of the items listed in the CPO guidance form that is present in the on-site binder.

37 - other violations of the chapter

1 ptsCorrected: NoRepeat: No

.13(2)(b): There is no documentation to verify an annual gas fired inspection has been performed on the pool heater. An annual gas fired inspections shall be performed by a qualified professional. Correct prior to follow up inspection.

Jun 2, 2025

Routine

Score: 1000 violations
No violations recorded for this inspection.

Jan 14, 2025

Permit/Opening

Score: 1000 violations
No violations recorded for this inspection.

Sep 23, 2024

Routine

Score: 851 violation

5 - emergency phone operational and accessible

Regulation: 511-3-5-.18(10)(c ) - (c) an operable, hard-wired, conventional telephone line or continuous powered source, weatherproof emergency phone shall be permanently installed in a conspicuous location within the pool enclosure and must be readily available to bathers at all tim

15 ptsCorrected: YesRepeat: No

Phone not working upon arrival. Got new phone while on site.

Jun 6, 2024

Routine

Score: 1000 violations
No violations recorded for this inspection.

Jan 8, 2024

Permit/Opening

Score: 1000 violations
No violations recorded for this inspection.

Aug 25, 2023

Routine

Score: 1000 violations
No violations recorded for this inspection.