May 14, 2026
Permit/Opening
100 HYACINTH LN PEACHTREE CITY, GA 30269
Inspection scores over time for this facility.
Georgia inspection history is score-based, with violations grouped under each recorded inspection.
Permit/Opening
Permit/Opening
The emergency phone system does not relay the correct address to 911 operators. This item must be corrected prior to permitting to prevent delays in response time.
Regulation: 511-3-5-.10(7) - (7) the vacuum line shall be protected with a self-closing, self-latching fitting that complies with the current iampo sps 4- special use suction fitting for swimming pools, spas and hot tubs.
The vacuum line is not covered with the correct fitting. The vacuum line shall be protected with a self-closing, self-latching fitting that complies with the current IAMPO SPS 4- Special Use Suction Fitting for Swimming Pools, Spas and Hot Tubs.
Re-inspection
Regulation: 511-3-5-.16(2)(a) - (a) every pool and spa shall be required to have at least one unit of disinfectant agent equipment that introduces the agent through the circulation system in compliance with this rule
There are tabs of chemicals present in the skimmers. Chlorine must be distributed to the pool via the filtration system. Remove the tabs from the skimmers. If the chemical feeders do not provide adequate chlorine to maintain chemical levels in the pool, then equipment may need to be changed to ensure proper functioning. Per CPO, chemical feeder functions. Tabs were placed in skimmers because water was added to the pool and he wanted to ensure chlorine level got back up. CPO removed tabs. Chemicals should never be added directly to the pool when bathers are present or when bathers have access to the pool.
Routine
Regulation: 511-3-5-.23(5)(g) - (g) failure to provide and maintain a barrier to inhibit unauthorized access to the outdoor facility when required.
Observed a gap in the barrier that allows for entry. CA: Facility shall maintain a barrier to inhibit unauthorized access.
Regulation: 511-3-5-.18(10)(c ) - (c) an operable, hard-wired, conventional telephone line or continuous powered source, weatherproof emergency phone shall be permanently installed in a conspicuous location within the pool enclosure and must be readily available to bathers at all tim
Observed that the emergency phone was not hard wired to call 911 directly. CA: Emergency phone shall be capable of calling 911 directly.
Regulation: 511-3-5-.23(5)(a) - (a) during operation, disinfectant levels are less than the minimum level specified in dph rule 511-3-5-.17. if the level of the disinfectant used is not specified in dph rule 511-3-5-.17, the disinfectant must be approved and kept at levels determin
Observed the chlorine level was below required levels. CA: Disinfectant levels shall be at the required level.
Regulation: 511-3-5-.07(4)(b) - (b) a flow meter measuring the rate of flow through the filter system with an appropriate range readable in gallons per minute (gpm) and accurate within ten percent actual flow shall be provided. the flow indicator shall be capable of measuring from
Observed that the flow meter was stuck and not working properly. CA: The flow meter shall be functioning.
Regulation: 511-3-5-.11(3)(g) - (g) the skimmer equalizer lines shall be protected by an approved cover/grated with a flow rating equal the maximum system flow divided by the number of skimmers in the system or the maximum flow rating of the skimmer, whichever is greater.
Observed that the equalizer lines did not have the float valve assembly present in each skimmer. CA: Equalizer lines shall be protected with an approved cover.
Regulation: 511-3-5-.11(3)(d) - (d) each skimmer shall have a weir that adjusts automatically to variations in water level over a minimum range of four inches.
Observed that there were no weirs present in all the skimmers. CA: Each skimmer shall have a weir that adjusts automatically to variations in water level over a minimum range of four inches.
Regulation: 511-3-5-.22(6) - (6) written documentation of the operator’s visits must be available at the pool facility. at a minimum, the written record must indicate the condition of the following items:
Observed facility did not have records of operator's visits available. CA: Written documentation of operator's visits must be available on site.
Permit/Opening
Routine
Permit/Opening
Routine
Permit/Opening