Peachtree City, Fayette County

Kedron Aquatic Center-Small Pool

202 FIELDHOUSE DR PEACHTREE CITY, GA 30269

Pool
Latest score
83
Apr 2, 2026
City
Peachtree City
County
Fayette
Inspections
8

Score history

Inspection scores over time for this facility.

Inspection history

Georgia inspection history is score-based, with violations grouped under each recorded inspection.

Apr 2, 2026

Permit/Opening

Score: 832 violations

2 - self-closing / self-latching gates

15 ptsCorrected: NoRepeat: No

The main doors from the building to the pool deck (bubble is no longer up) pushes out and does not have a release mechanism at least 54" above the ground. The building and pool will have renovations prior to next season. The access to the pool must be addressed prior to permitting next season. A lifeguard is always on duty during pool operations at this time. Access gates shall also comply with the requirements of this Rule and shall be equipped to accommodate a locking device. Barrier gates shall open away from the pool in facilities constructed after adoption of this chapter. Pedestrian access gates shall be self-closing and have a self-latching device. Gates other than pedestrian access gates shall have a self-latching device. Where the release mechanism of the self latching device is located less than fifty-four inches from the bottom of the gate, 1. The release mechanism shall be located on the pool side of the gate at least three inches below the top of the gate and 2. Any openings in the gate or barrier located within eighteen inches of the release mechanism shall be less than one-half inch. 3. Mechanisms controlled by an access card reader, key entry device or keypad shall be located on the outside of the access gate.

22 - signs: peak occupancy/pool/spa/signs legible and in clearview

Regulation: 511-3-5-.18(12)(a) - (a) the words "no diving" and the universal international symbol for “no diving” shall be permanently visible at the edge of the deck for water five feet in depth or less, placed only on the deck beside the depth markers, and shall conform to that ou

2 ptsCorrected: NoRepeat: No

Proper letter sizing for "no diving' is not present on the deck. The words "No Diving" and the universal international symbol for “NO DIVING” shall be permanently visible at the edge of the deck for water five feet in depth or less, placed only on the deck beside the depth markers, and shall conform to that outlined for depth markers

Mar 18, 2026

Permit/Opening

Score: 6412 violations

1 - barrier: pool enclosed/fencing in compliance

Regulation: .18(11)(d) - barrier

15 ptsCorrected: NoRepeat: No

The exterior fence gates around the pool are propped open. The main pedestrian gate is self closing, but was propped open with a trashcan. The double gate, maintenance entrance, is not self closing and must remain closed and locked to prevent unauthorized access to the pools. The front gate is closed and employee states he will go close the maintenance gate.

2 - self-closing / self-latching gates

Regulation: 511-3-5-.18(11)(h) - (h) access gates shall also comply with the requirements of this rule and shall be equipped to accommodate a locking device. barrier gates shall open away from the pool in facilities constructed after adoption of this chapter. pedestrian access gates

15 ptsCorrected: NoRepeat: No

The back double maintenance gate, near the pump room is left open. Access gates shall also comply with the requirements of this Rule and shall be equipped to accommodate a locking device. Barrier gates shall open away from the pool in facilities constructed after adoption of this chapter. Pedestrian access gates shall be self-closing and have a self-latching device. Gates other than pedestrian access gates shall have a self-latching device. Where the release mechanism of the self latching device is located less than fifty-four inches from the bottom of the gate, 1. The release mechanism shall be located on the pool side of the gate at least three inches below the top of the gate and 2. Any openings in the gate or barrier located within eighteen inches of the release mechanism shall be less than one-half inch. 3. Mechanisms controlled by an access card reader, key entry device or keypad shall be located on the outside of the access gate.

11 - appropriate lifesaving equipment present

Regulation: 511-3-5-.23(5)(h) - (h) absence of required lifesaving equipment on the deck or an emergency phone;

15 ptsCorrected: NoRepeat: No

The strong pole with body hook and ring buoy with attached rope are not present. Even though lifeguards are present, the required safety equipment must be present on the deck. Provide a minimum one-fourth inch diameter throwing rope one and one-half times the maximum width of the pool or fifty feet in length, whichever is less, to which has been firmly attached a ring buoy with an outside diameter of approximately fifteen inches or a similar flotation device which is U.S. Coast Guard approved and A light, strong pole not less than twelve feet long including body hook.

19 - adequate turnover rate

Regulation: 511-3-5-.07(1)(a) - (a) the equipment for a swimming pool shall be of adequate size to turn over the entire pool water capacity. the turnover rate for pools constructed after the adoption of this chapter shall not exceed the sum of one and one-half times the average wat

5 ptsCorrected: NoRepeat: No

The turnover for the pool does not meet the required 6 hour turnover rate. Ensure all equipment is working properly and adjust the location of the flowmeter if needed.

36 - daily recordkeeping: water testing and self inspection performed

Regulation: 511-3-5-.22(12) - (12) a safety self-inspection shall be conducted daily by the trained operator or responsible person and documented on a log sheet.

5 ptsCorrected: NoRepeat: No

There is no available documentation to verify a daily safety check is being performed. A safety self-inspection shall be conducted daily by the trained operator or responsible person and documented on a log sheet.

17 - skimmers/gutters maintained and operable

Regulation: 511-3-5-.11(3)(d) - (d) each skimmer shall have a weir that adjusts automatically to variations in water level over a minimum range of four inches.

4 ptsCorrected: NoRepeat: No

The weirs are not present in each skimmer. Replace weirs. Each skimmer shall have a weir that adjusts automatically to variations in water level over a minimum range of four inches.

35 - operator facility inspections performed; written documentation

Regulation: 511-3-5-.22(6) - (6) written documentation of the operator’s visits must be available at the pool facility. at a minimum, the written record must indicate the condition of the following items:

4 ptsCorrected: NoRepeat: No

There is no available documentation to verify the CPO is checking the required pool components per the code. Written documentation of the operator’s visits must be available at the pool facility. At a minimum, the written record must indicate the condition of the circulation and sanitizing equipment, pool deck, and safety equipment.

22 - signs: peak occupancy/pool/spa/signs legible and in clearview

Regulation: 511-3-5-.18(12)(c) - (c) the same sign in subsection (b) above or an additional sign will state under the heading “pool risks” the following items in clearly legible letters at least one inch high:

2 ptsCorrected: NoRepeat: No

The posted Pool Risk sign does not have all the required risks. See email for details on each required risk.

22 - signs: peak occupancy/pool/spa/signs legible and in clearview

Regulation: 511-3-5-.18(13)(c) - (c) a sign shall be posted stating the hours of operation in clear view near the entrance and shall state the theoretical peak occupancy.

2 ptsCorrected: NoRepeat: No

The bather load for the pool is not posted. Our records do not indicate a bather load. Additionally, when the bubble is up, the pool deck is decreased due to size of bubble. The Fire Department has indicated a maximum capacity of 480 within the bubble. If the City has any plans for the pools that would allow the surface area of the pools and deck to be calculated, we can determine the correct amount per the pool code.

22 - signs: peak occupancy/pool/spa/signs legible and in clearview

Regulation: 511-3-5-.18(12)(a) - (a) the words "no diving" and the universal international symbol for “no diving” shall be permanently visible at the edge of the deck for water five feet in depth or less, placed only on the deck beside the depth markers, and shall conform to that ou

2 ptsCorrected: NoRepeat: No

There is no universal symbol for no diving and proper letter sizing for "no diving' is not present on the deck. The words "No Diving" and the universal international symbol for “NO DIVING” shall be permanently visible at the edge of the deck for water five feet in depth or less, placed only on the deck beside the depth markers, and shall conform to that outlined for depth markers

37 - other violations of the chapter

1 ptsCorrected: NoRepeat: No

There is no documentation available to verify the annual gas fired inspection has been performed. See attached gas fired inspection sheet for requirements.

37 - other violations of the chapter

1 ptsCorrected: NoRepeat: No

The temperature of the pool exceeds 90 degrees F. For a pool at 90 degrees or more, a turnover rate of 30 minutes must be met. The filtration equipment for the pool can not handle a rate of 30 minutes. Therefore, the temperature of the pool must be reduced to 89 degrees F or below.

May 5, 2025

Routine

Score: 1000 violations
No violations recorded for this inspection.

Dec 31, 2024

Permit/Opening

Score: 1000 violations
No violations recorded for this inspection.

Oct 11, 2024

Routine

Score: 1000 violations
No violations recorded for this inspection.

Jun 6, 2024

Routine

Score: 1000 violations
No violations recorded for this inspection.

Jan 8, 2024

Permit/Opening

Score: 1000 violations
No violations recorded for this inspection.

Aug 25, 2023

Routine

Score: 1000 violations
No violations recorded for this inspection.