100 WOODROW WILSON WAY ROME, GA 30165
Inspection scores over time for this facility.
Georgia inspection history is score-based, with violations grouped under each recorded inspection.
Permit/Opening
Re-inspection
Routine
Regulation: 511-3-5-.23(5)(c ) - (c) the pump, automatic disinfectant equipment, or other equipment necessary for continuous filtration and disinfection of the swimming pool, spa, or recreational water park attraction is not working or is unable to maintain adequate turnover rate.
Chemical feeder (triclor)not operating due to being out of triclor tablets. CA: Hand feeding pool (pool closed) until triclor tablets are in. COS: Pool to be re-checked by health dept before opening.
Regulation: 511-3-5-.17(4) - (4) stabilizer (if used) cyanuric acid,ppm ideal: 30-50 maximum: 90 comments: if stabilizer is: too high: - may reduce chlorine efficacy too low: - chlorine residual rapidly destroyed by sunlight note: stabilizer is not needed in indoor or br
Observed Cya levels above maximum level for Georgia DPH Rules and Regulations CA: Discussed Cya levels with CPO (95) COS: CPO to lower level of Cya and pool to be re-checked and verified Cya levels are lower than maximum level
Permit/Opening
Re-inspection
Routine
Regulation: .17(1)(a)(b) - proper disinfectant level
Observed Free Chlorine levels below minimum 2 ppm CA: discussed FCL levels with manager and pool will be closed until re-inspescted. CPO to call 706-295-6316 to schedule a follow up inspection after pool chemicals are balanced and had time to sanitize pool.
Regulation: 511-3-5-.22(11) - (11) if the water test results are not in compliance with dph rule 511-3-5-.17, the operator shall close the pool, record findings, and make the necessary adjustments to the water chemistry to comply with the chapter. the chemicals used and amounts s
Observed no written documentation for daily testing of chemicals for July and August (documentation inconsistent) CA: discussed documentation with manager on duty
Re-inspection
Re-inspection
Regulation: .17(1)(a)(b) - proper disinfectant level
Observed Free chlorine level below minimum 2 ppm for public swimming pools. CA: discussed chlorine levels tested and discussed minimum, maximum and ideal levels with CPO-Pool is not opened at time of inspection-Discussed Health Department will need to re-check pool before opening with CPO and construction manager of Apartment complex after chemical adjustments with automatic feeders are implemented and maintained
Permit/Opening
Regulation: 511-3-5-.18(11)(h) - (h) access gates shall also comply with the requirements of this rule and shall be equipped to accommodate a locking device. barrier gates shall open away from the pool in facilities constructed after adoption of this chapter. pedestrian access gates
observed gate not self-latching at time of inspection. CA: discussed gate with Cox Pool Company
Regulation: 511-3-5-.22(2) - (2) the trained operator shall have a current certificate showing completion of an approved operator training course. a copy or the original certificate or documentation shall be available onsite for inspection by the health authority.
Observed no CPO certificate and contract for pool season 24. CA: discussed having a current certificate and contract with apartments for health department to review
Regulation: 511-3-5-.18(13)(c) - (c) a sign shall be posted stating the hours of operation in clear view near the entrance and shall state the theoretical peak occupancy.
Maximum occupancy load signage not observed. CA: discussed occupancy signage for pool with Cox Pool Company
Regulation: 511-3-5-.19(2)(e ) - (e) soap dispensers for providing either liquid or powdered soap shall be provided at each lavatory. the dispenser shall be of all metal or plastic. no glass shall be permitted in these units.
Observed no soap in the bathrooms at pool. CA: discussed having soap available in bathrooms at all times with Cox pool company