Atlanta, Fulton County

Gentry

3172 ROSWELL RD ATLANTA, GA 30305

Pool
Latest score
100
Jul 31, 2024
City
Atlanta
County
Fulton
Inspections
2

Score history

Inspection scores over time for this facility.

Inspection history

Georgia inspection history is score-based, with violations grouped under each recorded inspection.

Jul 31, 2024

Re-inspection

Score: 1000 violations
No violations recorded for this inspection.

Jul 26, 2024

Permit/Opening

Score: 864 violations

19 - adequate turnover rate

Regulation: 511-3-5-.07(1)(a) - (a) the equipment for a swimming pool shall be of adequate size to turn over the entire pool water capacity. the turnover rate for pools constructed after the adoption of this chapter shall not exceed the sum of one and one-half times the average wat

5 ptsCorrected: NoRepeat: No

Observed a turnover rate above 6 hrs.

(a) The equipment for a swimming pool shall be of adequate size to turn over the entire pool water capacity. The turnover rate for pools constructed after the adoption of this chapter shall not exceed the sum of one and one-half times the average water depth in feet; where the number of hours is equal to the number feet calculated, or exceed once every six hours whichever is less. Unless the rate is otherwise specified in subsection (b) below. This system shall be designed to give the proper turnover rate based on the manufacturer's recommended maximum pressure flow of the filter in dirty media condition of the filter, immediately prior to cleaning the filter.

PIC will ensure that all skimmers and baskets are cleaned prior to Reinspection.

17 - skimmers/gutters maintained and operable

Regulation: 511-3-5-.11(3)(d) - (d) each skimmer shall have a weir that adjusts automatically to variations in water level over a minimum range of four inches.

4 ptsCorrected: NoRepeat: No

Observed 0 out of 4 wires for the skimmers. EHS also observed that several skimmers baskets were turned over.

(d) Each skimmer shall have a weir that adjusts automatically to variations in water level over a minimum range of four inches.

EHS had PIC reorient the baskets and have PIC order wiers for the skimmers.

21 - cyanuric acid level not exceeding maximum

Regulation: 511-3-5-.17(4) - (4) stabilizer (if used) cyanuric acid,ppm ideal: 30-50 maximum: 90 comments: if stabilizer is: too high: - may reduce chlorine efficacy too low: - chlorine residual rapidly destroyed by sunlight note: stabilizer is not needed in indoor or br

4 ptsCorrected: NoRepeat: No

Observed a CYA level above the recommended threshold. See chemical levels for readings.

(4) Stabilizer (if used) Cyanuric acid,ppm Ideal: 30-50 Maximum: 90 Comments: If stabilizer is: Too High: - May reduce chlorine efficacy Too Low: - Chlorine Residual rapidly destroyed by sunlight Note: Stabilizer is not needed in indoor or brominated pools and spas.

PIC will rebalance the pool to ensure CYA in the proper range.

37 - other violations of the chapter

1 ptsCorrected: NoRepeat: No

Observed no gas fired inspection upon request and no sticker on the heater for the pool. 511-3-5-.13 (2) (b) - An annual gas fired inspection shall be performed by a qualified professional. PIC will contact the local fire authority or a company recognized by the local fire authority to inspect the heater for the pool.